Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng
{"title":"Feasibility study of multiplexing analog signals from SiPMs for a single layer monolithic PET detector design","authors":"Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng","doi":"10.1016/j.radmeas.2025.107399","DOIUrl":null,"url":null,"abstract":"<div><div>Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design, a single layer LSO crystal was used with dimensions <span><math><mrow><mn>40</mn><mspace></mspace><mi>mm</mi><mo>×</mo><mn>40</mn><mspace></mspace><mi>mm</mi><mo>×</mo><mn>4</mn><mspace></mspace><mi>mm</mi></mrow></math></span>, with 0.60 mm thickness of the ESR (enhanced specular reflector) films covering the crystal's top and bottom surfaces. The photons generated in the scintillation process induced by the gamma ray hitting the crystal were detected by four 1 × 8 SiPM (silicon photomultiplier) arrays placed along the four sides of the crystal. The scintillation light distribution detected by all the 32 SiPMs surrounding the crystal layer was then used to extract the gamma-crystal interaction location based on machine learning analysis. In this work, the spatial resolution of the detector module was explored when analog signals from each of the 32 SiPMs were summed to 28, 24, 20, 16, 12, 8, and 4 total outputs. This study showed that good spatial resolution can be achieved even when the number of read out channels is decreased by multiplexing, which can reduce the overall detector manufacturing cost.</div></div>","PeriodicalId":21055,"journal":{"name":"Radiation Measurements","volume":"182 ","pages":"Article 107399"},"PeriodicalIF":1.6000,"publicationDate":"2025-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Measurements","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1350448725000289","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In this work, a simulation study of a single layer monolithic detector module was performed with side read out of scintillation light using GATEv8.2. In this design, a single layer LSO crystal was used with dimensions , with 0.60 mm thickness of the ESR (enhanced specular reflector) films covering the crystal's top and bottom surfaces. The photons generated in the scintillation process induced by the gamma ray hitting the crystal were detected by four 1 × 8 SiPM (silicon photomultiplier) arrays placed along the four sides of the crystal. The scintillation light distribution detected by all the 32 SiPMs surrounding the crystal layer was then used to extract the gamma-crystal interaction location based on machine learning analysis. In this work, the spatial resolution of the detector module was explored when analog signals from each of the 32 SiPMs were summed to 28, 24, 20, 16, 12, 8, and 4 total outputs. This study showed that good spatial resolution can be achieved even when the number of read out channels is decreased by multiplexing, which can reduce the overall detector manufacturing cost.
期刊介绍:
The journal seeks to publish papers that present advances in the following areas: spontaneous and stimulated luminescence (including scintillating materials, thermoluminescence, and optically stimulated luminescence); electron spin resonance of natural and synthetic materials; the physics, design and performance of radiation measurements (including computational modelling such as electronic transport simulations); the novel basic aspects of radiation measurement in medical physics. Studies of energy-transfer phenomena, track physics and microdosimetry are also of interest to the journal.
Applications relevant to the journal, particularly where they present novel detection techniques, novel analytical approaches or novel materials, include: personal dosimetry (including dosimetric quantities, active/electronic and passive monitoring techniques for photon, neutron and charged-particle exposures); environmental dosimetry (including methodological advances and predictive models related to radon, but generally excluding local survey results of radon where the main aim is to establish the radiation risk to populations); cosmic and high-energy radiation measurements (including dosimetry, space radiation effects, and single event upsets); dosimetry-based archaeological and Quaternary dating; dosimetry-based approaches to thermochronometry; accident and retrospective dosimetry (including activation detectors), and dosimetry and measurements related to medical applications.