Deep regression 2D-3D ultrasound registration for liver motion correction in focal tumour thermal ablation

IF 2.8 Q3 ENGINEERING, BIOMEDICAL Healthcare Technology Letters Pub Date : 2025-02-17 DOI:10.1049/htl2.12117
Shuwei Xing, Derek W. Cool, David Tessier, Elvis C. S. Chen, Terry M. Peters, Aaron Fenster
{"title":"Deep regression 2D-3D ultrasound registration for liver motion correction in focal tumour thermal ablation","authors":"Shuwei Xing,&nbsp;Derek W. Cool,&nbsp;David Tessier,&nbsp;Elvis C. S. Chen,&nbsp;Terry M. Peters,&nbsp;Aaron Fenster","doi":"10.1049/htl2.12117","DOIUrl":null,"url":null,"abstract":"<p>Liver tumour ablation procedures require accurate placement of the needle applicator at the tumour centroid. The lower-cost and real-time nature of ultrasound (US) has advantages over computed tomography for applicator guidance, however, in some patients, liver tumours may be occult on US and tumour mimics can make lesion identification challenging. Image registration techniques can aid in interpreting anatomical details and identifying tumours, but their clinical application has been hindered by the tradeoff between alignment accuracy and runtime performance, particularly when compensating for liver motion due to patient breathing or movement. Therefore, we propose a 2D–3D US registration approach to enable intra-procedural alignment that mitigates errors caused by liver motion. Specifically, our approach can correlate imbalanced 2D and 3D US image features and use continuous 6D rotation representations to enhance the model's training stability. The dataset was divided into 2388, 196, and 193 image pairs for training, validation and testing, respectively. Our approach achieved a mean Euclidean distance error of <span></span><math>\n <semantics>\n <mrow>\n <mn>2.28</mn>\n <mspace></mspace>\n <mi>m</mi>\n <mi>m</mi>\n </mrow>\n <annotation>$2.28 \\,\\mathrm{m}\\mathrm{m}$</annotation>\n </semantics></math> <span></span><math>\n <semantics>\n <mo>±</mo>\n <annotation>$\\pm$</annotation>\n </semantics></math> <span></span><math>\n <semantics>\n <mrow>\n <mn>1.81</mn>\n <mspace></mspace>\n <mi>m</mi>\n <mi>m</mi>\n </mrow>\n <annotation>$1.81 \\,\\mathrm{m}\\mathrm{m}$</annotation>\n </semantics></math> and a mean geodesic angular error of <span></span><math>\n <semantics>\n <mrow>\n <mn>2.99</mn>\n <msup>\n <mspace></mspace>\n <mo>∘</mo>\n </msup>\n </mrow>\n <annotation>$2.99 \\,\\mathrm{^{\\circ }}$</annotation>\n </semantics></math> <span></span><math>\n <semantics>\n <mo>±</mo>\n <annotation>$\\pm$</annotation>\n </semantics></math> <span></span><math>\n <semantics>\n <mrow>\n <mn>1.95</mn>\n <msup>\n <mspace></mspace>\n <mo>∘</mo>\n </msup>\n </mrow>\n <annotation>$1.95 \\,\\mathrm{^{\\circ }}$</annotation>\n </semantics></math>, with a runtime of <span></span><math>\n <semantics>\n <mrow>\n <mn>0.22</mn>\n <mspace></mspace>\n <mi>s</mi>\n </mrow>\n <annotation>$0.22 \\,\\mathrm{s}$</annotation>\n </semantics></math> per 2D–3D US image pair. These results demonstrate that our approach can achieve accurate alignment and clinically acceptable runtime, indicating potential for clinical translation.</p>","PeriodicalId":37474,"journal":{"name":"Healthcare Technology Letters","volume":"12 1","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/htl2.12117","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Healthcare Technology Letters","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/htl2.12117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Liver tumour ablation procedures require accurate placement of the needle applicator at the tumour centroid. The lower-cost and real-time nature of ultrasound (US) has advantages over computed tomography for applicator guidance, however, in some patients, liver tumours may be occult on US and tumour mimics can make lesion identification challenging. Image registration techniques can aid in interpreting anatomical details and identifying tumours, but their clinical application has been hindered by the tradeoff between alignment accuracy and runtime performance, particularly when compensating for liver motion due to patient breathing or movement. Therefore, we propose a 2D–3D US registration approach to enable intra-procedural alignment that mitigates errors caused by liver motion. Specifically, our approach can correlate imbalanced 2D and 3D US image features and use continuous 6D rotation representations to enhance the model's training stability. The dataset was divided into 2388, 196, and 193 image pairs for training, validation and testing, respectively. Our approach achieved a mean Euclidean distance error of 2.28 m m $2.28 \,\mathrm{m}\mathrm{m}$ ± $\pm$ 1.81 m m $1.81 \,\mathrm{m}\mathrm{m}$ and a mean geodesic angular error of 2.99 $2.99 \,\mathrm{^{\circ }}$ ± $\pm$ 1.95 $1.95 \,\mathrm{^{\circ }}$ , with a runtime of 0.22 s $0.22 \,\mathrm{s}$ per 2D–3D US image pair. These results demonstrate that our approach can achieve accurate alignment and clinically acceptable runtime, indicating potential for clinical translation.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
深度回归 2D-3D 超声波配准用于病灶肿瘤热消融中的肝脏运动校正
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Healthcare Technology Letters
Healthcare Technology Letters Health Professions-Health Information Management
CiteScore
6.10
自引率
4.80%
发文量
12
审稿时长
22 weeks
期刊介绍: Healthcare Technology Letters aims to bring together an audience of biomedical and electrical engineers, physical and computer scientists, and mathematicians to enable the exchange of the latest ideas and advances through rapid online publication of original healthcare technology research. Major themes of the journal include (but are not limited to): Major technological/methodological areas: Biomedical signal processing Biomedical imaging and image processing Bioinstrumentation (sensors, wearable technologies, etc) Biomedical informatics Major application areas: Cardiovascular and respiratory systems engineering Neural engineering, neuromuscular systems Rehabilitation engineering Bio-robotics, surgical planning and biomechanics Therapeutic and diagnostic systems, devices and technologies Clinical engineering Healthcare information systems, telemedicine, mHealth.
期刊最新文献
Differential analysis of brain functional network parameters in MHE patients The Feasibility of Ambulatory Heart Rate Variability Monitoring in Non-Suicidal Self-Injury Signal-quality-aware multisensor fusion for atrial fibrillation detection Deep regression 2D-3D ultrasound registration for liver motion correction in focal tumour thermal ablation Writing the Signs: An Explainable Machine Learning Approach for Alzheimer's Disease Classification from Handwriting
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1