A Sensitive Ultrafiltration Plus RP-HPLC-FLD Method to Quantify Total and Free Perampanel Concentrations in the Plasma of Patients With Epilepsy: A Fully Validated Assay With Clinical Application.

IF 2.8 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Therapeutic Drug Monitoring Pub Date : 2025-02-18 DOI:10.1097/FTD.0000000000001311
Zhonghua Dong, Peng Wang, Xueyan Cui, Jinjuan Liu, Haiyan Shi, Yilei Yang, Jingya Xu, Qiaoyan Yi
{"title":"A Sensitive Ultrafiltration Plus RP-HPLC-FLD Method to Quantify Total and Free Perampanel Concentrations in the Plasma of Patients With Epilepsy: A Fully Validated Assay With Clinical Application.","authors":"Zhonghua Dong, Peng Wang, Xueyan Cui, Jinjuan Liu, Haiyan Shi, Yilei Yang, Jingya Xu, Qiaoyan Yi","doi":"10.1097/FTD.0000000000001311","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Perampanel (PER), a novel antiepileptic drug, exhibits high protein binding. Given the drug's susceptibility to various factors, including drug interactions, and the considerable variability in blood concentrations among individuals, solely measuring the total plasma concentration of PER may not provide comprehensive insights. This study aimed to establish an HPLC-FLD method to quantify both total and free PER in clinical samples.</p><p><strong>Methods: </strong>Analysis of total PER involved a straightforward sample preparation process involving plasma protein precipitation. Plasma samples were ultrafiltered to isolate the free portion of PER. Chromatographic separation was achieved on an InertSustain C18 column at a 1-mL/min flow rate using a gradient of acetonitrile and aqueous sodium acetate buffer at pH 4.4.</p><p><strong>Results: </strong>Calibration curves for total and free PER in plasma exhibited excellent linearity over the concentration ranges of 10-3000 and 0.5-100 ng/mL, respectively. The method was applied to analyze blood samples from patients with epilepsy quantitatively; the total concentration of perampanel in the plasma of the patients was in the range of 90.45-563.39 ng/mL, whereas the free concentration was in the range of 1.82-15.29 ng/mL. The plasma protein binding ratio of perampanel was normally between 97.09% and 99.29% and decreased in cases of hypoproteinemia.</p><p><strong>Conclusions: </strong>The method was rigorously validated for selectivity, accuracy, precision, and stability in accordance with established FDA and EMA guidelines. The developed method enables the rapid and accurate quantification of both total and free PER concentrations in the plasma of patients with epilepsy, offering technical support for its subsequent clinical application.</p>","PeriodicalId":23052,"journal":{"name":"Therapeutic Drug Monitoring","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Therapeutic Drug Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/FTD.0000000000001311","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Perampanel (PER), a novel antiepileptic drug, exhibits high protein binding. Given the drug's susceptibility to various factors, including drug interactions, and the considerable variability in blood concentrations among individuals, solely measuring the total plasma concentration of PER may not provide comprehensive insights. This study aimed to establish an HPLC-FLD method to quantify both total and free PER in clinical samples.

Methods: Analysis of total PER involved a straightforward sample preparation process involving plasma protein precipitation. Plasma samples were ultrafiltered to isolate the free portion of PER. Chromatographic separation was achieved on an InertSustain C18 column at a 1-mL/min flow rate using a gradient of acetonitrile and aqueous sodium acetate buffer at pH 4.4.

Results: Calibration curves for total and free PER in plasma exhibited excellent linearity over the concentration ranges of 10-3000 and 0.5-100 ng/mL, respectively. The method was applied to analyze blood samples from patients with epilepsy quantitatively; the total concentration of perampanel in the plasma of the patients was in the range of 90.45-563.39 ng/mL, whereas the free concentration was in the range of 1.82-15.29 ng/mL. The plasma protein binding ratio of perampanel was normally between 97.09% and 99.29% and decreased in cases of hypoproteinemia.

Conclusions: The method was rigorously validated for selectivity, accuracy, precision, and stability in accordance with established FDA and EMA guidelines. The developed method enables the rapid and accurate quantification of both total and free PER concentrations in the plasma of patients with epilepsy, offering technical support for its subsequent clinical application.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Therapeutic Drug Monitoring
Therapeutic Drug Monitoring 医学-毒理学
CiteScore
5.00
自引率
8.00%
发文量
213
审稿时长
4-8 weeks
期刊介绍: Therapeutic Drug Monitoring is a peer-reviewed, multidisciplinary journal directed to an audience of pharmacologists, clinical chemists, laboratorians, pharmacists, drug researchers and toxicologists. It fosters the exchange of knowledge among the various disciplines–clinical pharmacology, pathology, toxicology, analytical chemistry–that share a common interest in Therapeutic Drug Monitoring. The journal presents studies detailing the various factors that affect the rate and extent drugs are absorbed, metabolized, and excreted. Regular features include review articles on specific classes of drugs, original articles, case reports, technical notes, and continuing education articles.
期刊最新文献
A Sensitive Ultrafiltration Plus RP-HPLC-FLD Method to Quantify Total and Free Perampanel Concentrations in the Plasma of Patients With Epilepsy: A Fully Validated Assay With Clinical Application. Examining Different Methods to Assess Busulfan Exposure in Pediatric Hematopoietic Stem Cell Transplant Recipients. Predictive Performance of Bayesian Dosing Software for Vancomycin in Intensive Care Unit Patients. How to Determine a Therapeutic Reference Range for a Psychotropic Drug Systematically? Recommendations of the TDM Task Force of the AGNP. Significant Influence of Abemaciclib on Rivaroxaban.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1