Effect of scanning the palate in anatomically variant maxillary arches on the accuracy of complete arch implant scans: An in vitro study.

IF 4.3 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Prosthetic Dentistry Pub Date : 2025-02-25 DOI:10.1016/j.prosdent.2025.01.047
Kawther Ali, Sunee Limmeechokchai, Roberto Savignano, Charles Goodacre
{"title":"Effect of scanning the palate in anatomically variant maxillary arches on the accuracy of complete arch implant scans: An in vitro study.","authors":"Kawther Ali, Sunee Limmeechokchai, Roberto Savignano, Charles Goodacre","doi":"10.1016/j.prosdent.2025.01.047","DOIUrl":null,"url":null,"abstract":"<p><strong>Statement of problem: </strong>Intraorally scanning the palate may affect the accuracy of digital implant scans depending on the maxillary arch anatomy (arch form, palatal vault depth) and the number of implants.</p><p><strong>Purpose: </strong>The purpose of this in vitro study was to investigate the effect of scanning the palate on the accuracy of maxillary implant complete arch scans with 3 different palatal vault depths and 3 arch forms and also the number of implants.</p><p><strong>Material and methods: </strong>A maxillary edentulous cast was scanned using a desktop scanner and imported into a computer aided design and computer aided manufacturing (CAD-CAM) software program to create a digital control model. That model was duplicated and modified to create different digital control models that differ in palate depth (shallow, medium, deep), arch form (ovoid, square, tapered), and number of implants (4 or 6). The 18 digital files were used to print 18 physical casts that were scanned using 2 different techniques - palate-less (UP) and palate stitching (SP) - using an intraoral scanner. Each scanning technique was repeated 7 times, and a total of 252 scans (SP and UP) were obtained from the models and superimposed over the corresponding original digital control using an industrial metrology software program to obtain trueness and precision values for each scanning technique according to the different variables. The Kruskal-Wallis test was used to detect the differences in trueness and precision among the experimental groups and with different variables.</p><p><strong>Results: </strong>No significant association was found between the maxillary complete arch scanning technique (SP and UP) and the accuracy of implant complete arch maxillary digital scans (P=.167). Both scanning methods (SP and UP) were significantly different in trueness and precision when compared with the control group (P<.001). The accuracy between the scans was not affected by arch form or number of implants (P>.05). However, shallow complete arch maxillary scans were more accurate than medium depth scans (P<.001), although the difference was small.</p><p><strong>Conclusions: </strong>When 3 different palatal depths, 3 different arch forms, 4 versus 6 implants, and SP versus UP scans were examined, none of these variables were found to affect the accuracy of maxillary complete arch digital scans.</p>","PeriodicalId":16866,"journal":{"name":"Journal of Prosthetic Dentistry","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2025-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Prosthetic Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.prosdent.2025.01.047","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Statement of problem: Intraorally scanning the palate may affect the accuracy of digital implant scans depending on the maxillary arch anatomy (arch form, palatal vault depth) and the number of implants.

Purpose: The purpose of this in vitro study was to investigate the effect of scanning the palate on the accuracy of maxillary implant complete arch scans with 3 different palatal vault depths and 3 arch forms and also the number of implants.

Material and methods: A maxillary edentulous cast was scanned using a desktop scanner and imported into a computer aided design and computer aided manufacturing (CAD-CAM) software program to create a digital control model. That model was duplicated and modified to create different digital control models that differ in palate depth (shallow, medium, deep), arch form (ovoid, square, tapered), and number of implants (4 or 6). The 18 digital files were used to print 18 physical casts that were scanned using 2 different techniques - palate-less (UP) and palate stitching (SP) - using an intraoral scanner. Each scanning technique was repeated 7 times, and a total of 252 scans (SP and UP) were obtained from the models and superimposed over the corresponding original digital control using an industrial metrology software program to obtain trueness and precision values for each scanning technique according to the different variables. The Kruskal-Wallis test was used to detect the differences in trueness and precision among the experimental groups and with different variables.

Results: No significant association was found between the maxillary complete arch scanning technique (SP and UP) and the accuracy of implant complete arch maxillary digital scans (P=.167). Both scanning methods (SP and UP) were significantly different in trueness and precision when compared with the control group (P<.001). The accuracy between the scans was not affected by arch form or number of implants (P>.05). However, shallow complete arch maxillary scans were more accurate than medium depth scans (P<.001), although the difference was small.

Conclusions: When 3 different palatal depths, 3 different arch forms, 4 versus 6 implants, and SP versus UP scans were examined, none of these variables were found to affect the accuracy of maxillary complete arch digital scans.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Prosthetic Dentistry
Journal of Prosthetic Dentistry 医学-牙科与口腔外科
CiteScore
7.00
自引率
13.00%
发文量
599
审稿时长
69 days
期刊介绍: The Journal of Prosthetic Dentistry is the leading professional journal devoted exclusively to prosthetic and restorative dentistry. The Journal is the official publication for 24 leading U.S. international prosthodontic organizations. The monthly publication features timely, original peer-reviewed articles on the newest techniques, dental materials, and research findings. The Journal serves prosthodontists and dentists in advanced practice, and features color photos that illustrate many step-by-step procedures. The Journal of Prosthetic Dentistry is included in Index Medicus and CINAHL.
期刊最新文献
Accuracy of complete arch implant scans recorded by using intraoral and extraoral photogrammetry systems. A meta-analysis of the accuracy of different measuring techniques to evaluate the marginal and internal gap of a fixed dental prosthesis: The American Academy of Fixed Prosthodontics, Research in Fixed Prosthodontics Committee. Accuracy of registration between digitized extraoral scan bodies and virtual casts: Effect of the edentulous area, tooth anatomy, and registration method. An AI-based tool for prosthetic crown segmentation serving automated intraoral scan-to-CBCT registration in challenging high artifact scenarios. Comparison of scanning depth in widened root canals: An analysis of three intraoral scanners and two scanning techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1