IF 9 1区 医学 Q1 RESPIRATORY SYSTEM Thorax Pub Date : 2025-02-27 DOI:10.1136/thorax-2024-221763
Julia Dielesen, Lesedi J Ledwaba-Chapman, Pragna Kasetti, Noori Fatima Husain, Timothy C Skinner, Martino F Pengo, Teresa Whiteman, Koula Asimakopoulou, Simon Merritt, David Jones, Peter Dickel, Siddiq Pulakal, Neil R Ward, Justin Pepperell, Joerg Steier, S Amanda Sathyapala
{"title":"Six early CPAP-usage behavioural patterns determine peak CPAP adherence and permit tailored intervention, in patients with obstructive sleep apnoea","authors":"Julia Dielesen, Lesedi J Ledwaba-Chapman, Pragna Kasetti, Noori Fatima Husain, Timothy C Skinner, Martino F Pengo, Teresa Whiteman, Koula Asimakopoulou, Simon Merritt, David Jones, Peter Dickel, Siddiq Pulakal, Neil R Ward, Justin Pepperell, Joerg Steier, S Amanda Sathyapala","doi":"10.1136/thorax-2024-221763","DOIUrl":null,"url":null,"abstract":"Background High rates of non-adherence to continuous positive airway pressure (CPAP) in obstructive sleep apnoea hamper good clinical outcomes. Current recommendations assumes two behaviours (adherence and non-adherence) and days 7–90 follow-up post-CPAP initiation mitigates against non-adherence. Objectives To investigate associations between early CPAP-usage behaviours and (1) CPAP adherence at month 3 of treatment and (2) sleep centres’ treatment pathways (the procedures patients undergo that may affect barriers or facilitators of CPAP adherence). Methods We conducted growth mixture modelling (GMM) on retrospective data from 1000 patients at 5 UK sleep centres. Night 1 to month 3 telemonitored CPAP-usage data were downloaded from 200 patients per centre who started CPAP in 2019 (100) or 2020 (100). Adherence was defined using accepted criteria (mean CPAP-usage ≥4 hours/night for ≥70% of nights). Results GMM identified six distinct CPAP-usage behaviour patterns over month 1. In four (54% of patients), CPAP-usage increased or decreased, in two (remaining 46%), CPAP-usage/non-usage was consistent. 62% of the cohort were non-adherent by month 3, despite pathways following current recommendations. 98% of patients who were non-adherent by month 3 were already non-adherent by month 1. Regression analysis with a separate dataset demonstrated that early CPAP-usage behaviour explained 86% of the variance in CPAP non-adherence at month 3. Conclusions These data, supported by previous work, indicate that recommended day 30–90 follow-up is too late to prevent CPAP non-adherence. Determining CPAP-usage behavioural pattern in week 2 identifies risk of CPAP non-adherence at month 3 and permits the possibility of tailored interventions. Data are available on reasonable request.","PeriodicalId":23284,"journal":{"name":"Thorax","volume":"35 1","pages":""},"PeriodicalIF":9.0000,"publicationDate":"2025-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thorax","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/thorax-2024-221763","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

Abstract

Background High rates of non-adherence to continuous positive airway pressure (CPAP) in obstructive sleep apnoea hamper good clinical outcomes. Current recommendations assumes two behaviours (adherence and non-adherence) and days 7–90 follow-up post-CPAP initiation mitigates against non-adherence. Objectives To investigate associations between early CPAP-usage behaviours and (1) CPAP adherence at month 3 of treatment and (2) sleep centres’ treatment pathways (the procedures patients undergo that may affect barriers or facilitators of CPAP adherence). Methods We conducted growth mixture modelling (GMM) on retrospective data from 1000 patients at 5 UK sleep centres. Night 1 to month 3 telemonitored CPAP-usage data were downloaded from 200 patients per centre who started CPAP in 2019 (100) or 2020 (100). Adherence was defined using accepted criteria (mean CPAP-usage ≥4 hours/night for ≥70% of nights). Results GMM identified six distinct CPAP-usage behaviour patterns over month 1. In four (54% of patients), CPAP-usage increased or decreased, in two (remaining 46%), CPAP-usage/non-usage was consistent. 62% of the cohort were non-adherent by month 3, despite pathways following current recommendations. 98% of patients who were non-adherent by month 3 were already non-adherent by month 1. Regression analysis with a separate dataset demonstrated that early CPAP-usage behaviour explained 86% of the variance in CPAP non-adherence at month 3. Conclusions These data, supported by previous work, indicate that recommended day 30–90 follow-up is too late to prevent CPAP non-adherence. Determining CPAP-usage behavioural pattern in week 2 identifies risk of CPAP non-adherence at month 3 and permits the possibility of tailored interventions. Data are available on reasonable request.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Thorax
Thorax 医学-呼吸系统
CiteScore
16.10
自引率
2.00%
发文量
197
审稿时长
1 months
期刊介绍: Thorax stands as one of the premier respiratory medicine journals globally, featuring clinical and experimental research articles spanning respiratory medicine, pediatrics, immunology, pharmacology, pathology, and surgery. The journal's mission is to publish noteworthy advancements in scientific understanding that are poised to influence clinical practice significantly. This encompasses articles delving into basic and translational mechanisms applicable to clinical material, covering areas such as cell and molecular biology, genetics, epidemiology, and immunology.
期刊最新文献
Early clinical remission and its role in lung function decline and exacerbation in adult Korean patients with asthma Improving uptake of lung cancer screening: an observational study on the impact of timed appointments and reminders. Impact of COPD on cardiovascular risk factors and outcomes in people with established cardiovascular disease Vasodilator-induced selective pulmonary oedema in sarcoidosis-associated pulmonary hypertension with pulmonary venous stenosis Six early CPAP-usage behavioural patterns determine peak CPAP adherence and permit tailored intervention, in patients with obstructive sleep apnoea
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1