A New Chromogenic Assay for Direct Detection of Staphylocoagulase

Małgorzata Bulanda , Zenon Weęgrzynowicz , Marek Ciurak , Janusz Kowalczyk , Gotfryd Kupryszewski , Maria Gruszka , Piotr B. Heczko , Gerhard Pulverer
{"title":"A New Chromogenic Assay for Direct Detection of Staphylocoagulase","authors":"Małgorzata Bulanda ,&nbsp;Zenon Weęgrzynowicz ,&nbsp;Marek Ciurak ,&nbsp;Janusz Kowalczyk ,&nbsp;Gotfryd Kupryszewski ,&nbsp;Maria Gruszka ,&nbsp;Piotr B. Heczko ,&nbsp;Gerhard Pulverer","doi":"10.1016/S0176-6724(88)80147-0","DOIUrl":null,"url":null,"abstract":"<div><p>Tube test for detection of staphylococcal coagulase, despite of many disadvantages, is commonly used in clinical microbiology for identification of <em>Staphylococcus aureus</em>. In this paper a new chromogenic method for detection of the coagulase directly in staphylococcal cultures is described and evaluated on the basis of a comparison with the standard tube assay. The chromogenic assay appeared to be as sensitive as the tube test but results of the former one can be read in a few hours without any apparatus.</p></div><div><p>Trotz mancher Nachteile wird der Röhrchentest generell zum Nachweis der Staphylokokken-Koagulase in der medizinischen Mikrobiologie verwendet, um die Spezies <em>Staphylococcus aureus</em> zu identifizieren. In vorliegender Arbeit wird eine neue chromogene Methode zum Nachweis der Koagulase direkt in der Staphylokokken-Kultur vorgestellt und mit dem Standard-Röhrchentest verglichen. Der chromogene Nachweistest erwies sich dem Standard-Röhrchentest als ebenbürtig, kann aber in wenigen Stunden ohne apparative Hilfe abgelesen werden.</p></div>","PeriodicalId":101291,"journal":{"name":"Zentralblatt für Bakteriologie, Mikrobiologie und Hygiene. Series A: Medical Microbiology, Infectious Diseases, Virology, Parasitology","volume":"270 1","pages":"Pages 115-121"},"PeriodicalIF":0.0000,"publicationDate":"1988-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0176-6724(88)80147-0","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt für Bakteriologie, Mikrobiologie und Hygiene. Series A: Medical Microbiology, Infectious Diseases, Virology, Parasitology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0176672488801470","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Tube test for detection of staphylococcal coagulase, despite of many disadvantages, is commonly used in clinical microbiology for identification of Staphylococcus aureus. In this paper a new chromogenic method for detection of the coagulase directly in staphylococcal cultures is described and evaluated on the basis of a comparison with the standard tube assay. The chromogenic assay appeared to be as sensitive as the tube test but results of the former one can be read in a few hours without any apparatus.

Trotz mancher Nachteile wird der Röhrchentest generell zum Nachweis der Staphylokokken-Koagulase in der medizinischen Mikrobiologie verwendet, um die Spezies Staphylococcus aureus zu identifizieren. In vorliegender Arbeit wird eine neue chromogene Methode zum Nachweis der Koagulase direkt in der Staphylokokken-Kultur vorgestellt und mit dem Standard-Röhrchentest verglichen. Der chromogene Nachweistest erwies sich dem Standard-Röhrchentest als ebenbürtig, kann aber in wenigen Stunden ohne apparative Hilfe abgelesen werden.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种新的直接检测葡萄凝固酶的显色法
检测葡萄球菌的检测,阴性分流的大白天通用财务联合报用于查明葡萄球菌。在这幅新的鞋中,有一种全新的寻找行为的直觉的方法,就是在标准审计的基础上进行评价。那种让人对音乐敏感的次品只是因为尽管有一些缺点,但一般而言,管状动脉检查常用来证明医疗微生物学中有一种葡萄球菌凝固剂,从而识别这种葡萄球菌。介绍了一种新的次品次品测试为标准套筒次品
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Bactec-system in the diagnosis of tuberculosis comparison of a conventional and the radiometric method (Bactec) for culturing, differentiation and susceptibility testing of Mycobacteria GasPak plus versus anaerocult a — two carbon dioxide/hydrogen systems for cultivation of anaerobes Monoclonal antibodies to protein I for serotyping of Neisseria gonorrhoeae: Correlation of serotype with bactericidal activity Genome type analysis of certain adenovirus serotypes of subgenus D Detection and interspecies-transformation of a β-Lactamase-encoding plasmid from Pasteurella haemolytica
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1