Aaron Daniel Brake, Sivani Lingam, Vince Galate, Robert Turner, Michael G Abraham
{"title":"Balloon occlusion testing for non-sinus-stenosis venous pulsatile tinnitus: A technical case series.","authors":"Aaron Daniel Brake, Sivani Lingam, Vince Galate, Robert Turner, Michael G Abraham","doi":"10.1177/15910199251323011","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Pulsatile tinnitus (PT) affects ∼ 10% of the population and can be debilitating. Venous etiologies of PT are increasingly recognized. Identifying the symptomatic vessel, particularly with multiple venous anomalies, remains challenging.</p><p><strong>Methods: </strong>In this case series, we utilized venous balloon occlusion testing (vBOT) as a real-time diagnostic tool to identify symptomatic vessels in non-sinus stenosis venous PT. vBOT involved using a transform balloon (7 mm × 7 mm) under fluoroscopic guidance to occlude the venous anomaly, with immediate assessment of symptom resolution.</p><p><strong>Results: </strong>We report four cases involving high-riding jugular bulbs, jugular bulb diverticula, and enlarged emissary veins. vBOT successfully identified the culprit vessels, guiding targeted endovascular coil embolization. These procedures led to significant symptom resolution in all cases, though the varied patient responses underscored the importance of a tailored, iterative approach, particularly in those with bilateral symptoms or multiple venous variants.</p><p><strong>Conclusion: </strong>This series illustrates the utility of vBOT in accurately identifying symptomatic vessels in non-sinus stenosis venous PT, enabling effective, targeted interventions. While vBOT is a valuable diagnostic tool, its limitations, including potential false negatives due to PT variability or ambient noise, must be considered. Incorporating vBOT into the diagnostic framework for PT can enhance precision in vessel selection and improve patient outcomes, particularly in cases with uncommon venous etiologies.</p>","PeriodicalId":49174,"journal":{"name":"Interventional Neuroradiology","volume":" ","pages":"15910199251323011"},"PeriodicalIF":1.5000,"publicationDate":"2025-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11869226/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Interventional Neuroradiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15910199251323011","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Pulsatile tinnitus (PT) affects ∼ 10% of the population and can be debilitating. Venous etiologies of PT are increasingly recognized. Identifying the symptomatic vessel, particularly with multiple venous anomalies, remains challenging.
Methods: In this case series, we utilized venous balloon occlusion testing (vBOT) as a real-time diagnostic tool to identify symptomatic vessels in non-sinus stenosis venous PT. vBOT involved using a transform balloon (7 mm × 7 mm) under fluoroscopic guidance to occlude the venous anomaly, with immediate assessment of symptom resolution.
Results: We report four cases involving high-riding jugular bulbs, jugular bulb diverticula, and enlarged emissary veins. vBOT successfully identified the culprit vessels, guiding targeted endovascular coil embolization. These procedures led to significant symptom resolution in all cases, though the varied patient responses underscored the importance of a tailored, iterative approach, particularly in those with bilateral symptoms or multiple venous variants.
Conclusion: This series illustrates the utility of vBOT in accurately identifying symptomatic vessels in non-sinus stenosis venous PT, enabling effective, targeted interventions. While vBOT is a valuable diagnostic tool, its limitations, including potential false negatives due to PT variability or ambient noise, must be considered. Incorporating vBOT into the diagnostic framework for PT can enhance precision in vessel selection and improve patient outcomes, particularly in cases with uncommon venous etiologies.
期刊介绍:
Interventional Neuroradiology (INR) is a peer-reviewed clinical practice journal documenting the current state of interventional neuroradiology worldwide. INR publishes original clinical observations, descriptions of new techniques or procedures, case reports, and articles on the ethical and social aspects of related health care. Original research published in INR is related to the practice of interventional neuroradiology...