Abrasive induced discharge in solar array drive assembly: Experiment and Monte Carlo simulation

IF 1.9 4区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC Journal of Electrostatics Pub Date : 2025-03-02 DOI:10.1016/j.elstat.2025.104048
Zhiang Ding , Qi Chen , Chengshan Liu , Zhiyuan Qian
{"title":"Abrasive induced discharge in solar array drive assembly: Experiment and Monte Carlo simulation","authors":"Zhiang Ding ,&nbsp;Qi Chen ,&nbsp;Chengshan Liu ,&nbsp;Zhiyuan Qian","doi":"10.1016/j.elstat.2025.104048","DOIUrl":null,"url":null,"abstract":"<div><div>Abrasive-induced arc discharge is considered a significant threat to the failure of Solar Array Drive Assembly (SADA). This study attempts to identify the causes of discharge faults in SADA and propose protective strategies. Experiments on the mechanism of abrasive-induced discharge using the equivalent structural components of the SADA electrical transmission and corresponding simulations using Particle-in-Cell Monte-Carlo-Collision (PIC-MCC) calculations are performed. The characteristic voltage-current curves, time evolution of arc and glow discharges of the failed structure were experimentally obtained. The results showed that the discharge characteristic curves with abrasives were higher and steeper than those without abrasives under the same voltages. Through simulations, the plasma distribution, electric field intensity, and potential distribution resulting from a break were obtained, revealing that the flow forms slightly away from the electrode tips, and the electric field distortion induced by abrasives has a significant impact on the discharge. Plasma discharge treatment was further conducted on the insulating material, and an increase in the flashover voltage of the treated insulating material was observed. The relationship between the discharge voltage of the structural component and the number of discharges was also investigated. The results indicated that there was not a significant correlation between the discharge voltage and the number of discharges. However, the presence of abrasives did have an impact on the discharge voltage. It is evident from the above that the failures induced by abrasion-triggered discharges inside the SADA cannot be overlooked. Treating the insulating material with plasma is recommended to increase its flashover voltage in surface flashover situations. This article represents original research, and its findings are of significant value in exploring the mechanism of abrasion-induced discharges leading to the failure of the internal conductive ring in SADA.</div></div>","PeriodicalId":54842,"journal":{"name":"Journal of Electrostatics","volume":"135 ","pages":"Article 104048"},"PeriodicalIF":1.9000,"publicationDate":"2025-03-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrostatics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0304388625000208","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Abrasive-induced arc discharge is considered a significant threat to the failure of Solar Array Drive Assembly (SADA). This study attempts to identify the causes of discharge faults in SADA and propose protective strategies. Experiments on the mechanism of abrasive-induced discharge using the equivalent structural components of the SADA electrical transmission and corresponding simulations using Particle-in-Cell Monte-Carlo-Collision (PIC-MCC) calculations are performed. The characteristic voltage-current curves, time evolution of arc and glow discharges of the failed structure were experimentally obtained. The results showed that the discharge characteristic curves with abrasives were higher and steeper than those without abrasives under the same voltages. Through simulations, the plasma distribution, electric field intensity, and potential distribution resulting from a break were obtained, revealing that the flow forms slightly away from the electrode tips, and the electric field distortion induced by abrasives has a significant impact on the discharge. Plasma discharge treatment was further conducted on the insulating material, and an increase in the flashover voltage of the treated insulating material was observed. The relationship between the discharge voltage of the structural component and the number of discharges was also investigated. The results indicated that there was not a significant correlation between the discharge voltage and the number of discharges. However, the presence of abrasives did have an impact on the discharge voltage. It is evident from the above that the failures induced by abrasion-triggered discharges inside the SADA cannot be overlooked. Treating the insulating material with plasma is recommended to increase its flashover voltage in surface flashover situations. This article represents original research, and its findings are of significant value in exploring the mechanism of abrasion-induced discharges leading to the failure of the internal conductive ring in SADA.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Electrostatics
Journal of Electrostatics 工程技术-工程:电子与电气
CiteScore
4.00
自引率
11.10%
发文量
81
审稿时长
49 days
期刊介绍: The Journal of Electrostatics is the leading forum for publishing research findings that advance knowledge in the field of electrostatics. We invite submissions in the following areas: Electrostatic charge separation processes. Electrostatic manipulation of particles, droplets, and biological cells. Electrostatically driven or controlled fluid flow. Electrostatics in the gas phase.
期刊最新文献
Abrasive induced discharge in solar array drive assembly: Experiment and Monte Carlo simulation Operando space charge distribution measurements coupled with cyclic voltammetry Effects of pre-charger length, symmetry and insertion depth on PM2.5 removal efficiency for electrostatic precipitator (ESP)-type wearable personal air cleaner Editorial Board Geometric profile design effect on composite insulator performance in rainy climate using electrostatic field analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1