A Quantitative Comparison of Electrode Positions for Respiratory Surface EMG

IF 4.5 2区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Transactions on Biomedical Engineering Pub Date : 2025-02-18 DOI:10.1109/TBME.2025.3543644
Andra Oltmann;Jan Graßhoff;Nils Lange;Tobias Knopp;Philipp Rostalski
{"title":"A Quantitative Comparison of Electrode Positions for Respiratory Surface EMG","authors":"Andra Oltmann;Jan Graßhoff;Nils Lange;Tobias Knopp;Philipp Rostalski","doi":"10.1109/TBME.2025.3543644","DOIUrl":null,"url":null,"abstract":"<italic>Objective:</i> Respiratory surface electromyography (sEMG) is a promising physiological signal for analyzing respiratory effort, patient-ventilator asynchrony, and respiratory training. In clinical research, a wide variety of different setups are used and no consensus has yet been reached on the positioning of electrodes. Therefore, this work aims to quantitatively compare both unilateral and bilateral bipolar electrode leads. <italic>Methods:</i> Recordings of diaphragmatic and intercostal muscle activity were performed in 20 young and healthy adults using a setup with 64 electrodes placed in relation to prominent anatomical lines. Subjects completed three breathing maneuvers: 300 s quiet breathing, 5 maximum inspiratory pressure (MIP) trials, and 15 breaths of resistance breathing at 20 % of the MIP. To quantify the performance of differential electrode leads, three metrics were determined: the ratio between inspiratory muscle activity and (1) baseline noise (SNR<sub>base</sub>), (2) expiratory muscle activity (SNR<sub>exp</sub>), and (3) ECG interference (SNR<sub>EMG-ECG</sub>). <italic>Results:</i> The study revealed considerable differences between bipolar electrode positions. Our results support the use of bilateral positions on the midclavicular line and parasternal line for measuring diaphragm and intercostal activity. For intercostal muscles, there is a high flexibility in positioning electrodes more lateral or medial, if necessary. Unilateral leads do not appear to outperform the bilateral configuration as SNR metrics were consistently smaller. <italic>Conclusion:</i> This study provides recommendations for electrode placements and is a first step towards standardization of respiratory sEMG measurements. <italic>Significance:</i> This electrode lead standardization will be essential to increase clinical acceptance in the future.","PeriodicalId":13245,"journal":{"name":"IEEE Transactions on Biomedical Engineering","volume":"72 8","pages":"2437-2446"},"PeriodicalIF":4.5000,"publicationDate":"2025-02-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10892043","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10892043/","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Respiratory surface electromyography (sEMG) is a promising physiological signal for analyzing respiratory effort, patient-ventilator asynchrony, and respiratory training. In clinical research, a wide variety of different setups are used and no consensus has yet been reached on the positioning of electrodes. Therefore, this work aims to quantitatively compare both unilateral and bilateral bipolar electrode leads. Methods: Recordings of diaphragmatic and intercostal muscle activity were performed in 20 young and healthy adults using a setup with 64 electrodes placed in relation to prominent anatomical lines. Subjects completed three breathing maneuvers: 300 s quiet breathing, 5 maximum inspiratory pressure (MIP) trials, and 15 breaths of resistance breathing at 20 % of the MIP. To quantify the performance of differential electrode leads, three metrics were determined: the ratio between inspiratory muscle activity and (1) baseline noise (SNRbase), (2) expiratory muscle activity (SNRexp), and (3) ECG interference (SNREMG-ECG). Results: The study revealed considerable differences between bipolar electrode positions. Our results support the use of bilateral positions on the midclavicular line and parasternal line for measuring diaphragm and intercostal activity. For intercostal muscles, there is a high flexibility in positioning electrodes more lateral or medial, if necessary. Unilateral leads do not appear to outperform the bilateral configuration as SNR metrics were consistently smaller. Conclusion: This study provides recommendations for electrode placements and is a first step towards standardization of respiratory sEMG measurements. Significance: This electrode lead standardization will be essential to increase clinical acceptance in the future.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
呼吸表肌电图电极位置的定量比较。
目的:呼吸表面肌电图(sEMG)是一种很有前途的生理信号,可用于分析呼吸用力、患者-呼吸机非同步以及呼吸训练。在临床研究中,使用了各种不同的设置,但尚未就电极的定位达成共识。因此,这项工作旨在定量比较单侧和双极电极引线。方法:对20名年轻健康的成年人进行膈肌和肋间肌活动的记录,使用与突出解剖线相关的64个电极设置。受试者完成三个呼吸动作:300秒安静呼吸,5次最大吸气压力(MIP)试验,以及15次阻力呼吸,呼气压力为最大吸气压力的20%。为了量化差分电极引线的性能,确定了三个指标:吸气肌活动与(1)基线噪声(SNRbase)之比,(2)呼气肌活动(SNRexp),(3)心电干扰(SNREMG-ECG)。结果:研究显示双极电极位置有相当大的差异。我们的结果支持使用锁骨中线和胸骨旁线的双侧位置来测量横膈膜和肋间活动。对于肋间肌,如果有必要,将电极放置在更外侧或内侧有很高的灵活性。由于信噪比指标始终较小,单边引线的性能似乎并不优于双边配置。结论:本研究为电极放置提供了建议,是实现呼吸肌电图测量标准化的第一步。意义:该电极导联标准化对于提高未来临床接受度至关重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Biomedical Engineering
IEEE Transactions on Biomedical Engineering 工程技术-工程:生物医学
CiteScore
9.40
自引率
4.30%
发文量
880
审稿时长
2.5 months
期刊介绍: IEEE Transactions on Biomedical Engineering contains basic and applied papers dealing with biomedical engineering. Papers range from engineering development in methods and techniques with biomedical applications to experimental and clinical investigations with engineering contributions.
期刊最新文献
MBGFF Model for EEG-Text Generation Under Multi-Task Parallel Imagination. FEMBA on the Edge: Physiologically-Aware Pre-Training, Quantization, and Deployment of a Bidirectional Mamba EEG Foundation Model on an Ultra-Low Power Microcontroller. Predictive Gait Generation Based on Passive Morphology: Kinematic and Kinetic Optimization. Spacing-Compensated Measurement of the Acoustoelectric Interaction Constant for Quantitative Current-Density Imaging in Saline and Brain Tissue. A PET/CT Cross-Modal Wavelet Fusion and Pseudo-Mask Guided Network With Frozen SAM Decoder for Multiple Myeloma Segmentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1