Validation of the estimated Effect of Ankle Foot Orthoses on Spinal Cord Injury Gait Using Subject-Adjusted Musculoskeletal Models.

Sergio Galindo-Leon, Inge Eriks-Hoogland, Kenji Suzuki, Diego Paez-Granados
{"title":"Validation of the estimated Effect of Ankle Foot Orthoses on Spinal Cord Injury Gait Using Subject-Adjusted Musculoskeletal Models.","authors":"Sergio Galindo-Leon, Inge Eriks-Hoogland, Kenji Suzuki, Diego Paez-Granados","doi":"10.1109/EMBC53108.2024.10782279","DOIUrl":null,"url":null,"abstract":"<p><p>Simulation of assistive devices on pathological gait through musculoskeletal models offers the potential and advantages of estimating the effect of the device in several biomechanical variables and the device characteristics ahead of manufacturing. In this study, we introduce a novel musculoskeletal modelling approach to simulate the biomechanical impact of ankle foot orthoses (AFO) on gait in individuals with spinal cord injury (SCI). Leveraging data from the Swiss Paraplegic Center, we constructed anatomically and muscularly scaled models for SCI-AFO users, aiming to predict changes in gait kinematics and kinetics. The importance of this work lies in its potential to enhance rehabilitation strategies and improve quality of life by enabling the pre-manufacturing assessment of assistive devices. Despite the application of musculoskeletal models in simulating walking aids effects in other conditions, no predictive model currently exists for SCI gait. Evaluation through RMSE showed similar results compared with other pathologies, simulation errors ranged between 0.23 to 2.3 degrees in kinematics. Moreover, the model was able to capture ankle joint muscular asymmetries and predict symmetry improvements with AFO use. However, the simulation did not reveal all the AFO effects, indicating a need for more personalized model parameters and optimized muscle activation to fully replicate orthosis effects on SCI gait.</p>","PeriodicalId":72237,"journal":{"name":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","volume":"2024 ","pages":"1-7"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMBC53108.2024.10782279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Simulation of assistive devices on pathological gait through musculoskeletal models offers the potential and advantages of estimating the effect of the device in several biomechanical variables and the device characteristics ahead of manufacturing. In this study, we introduce a novel musculoskeletal modelling approach to simulate the biomechanical impact of ankle foot orthoses (AFO) on gait in individuals with spinal cord injury (SCI). Leveraging data from the Swiss Paraplegic Center, we constructed anatomically and muscularly scaled models for SCI-AFO users, aiming to predict changes in gait kinematics and kinetics. The importance of this work lies in its potential to enhance rehabilitation strategies and improve quality of life by enabling the pre-manufacturing assessment of assistive devices. Despite the application of musculoskeletal models in simulating walking aids effects in other conditions, no predictive model currently exists for SCI gait. Evaluation through RMSE showed similar results compared with other pathologies, simulation errors ranged between 0.23 to 2.3 degrees in kinematics. Moreover, the model was able to capture ankle joint muscular asymmetries and predict symmetry improvements with AFO use. However, the simulation did not reveal all the AFO effects, indicating a need for more personalized model parameters and optimized muscle activation to fully replicate orthosis effects on SCI gait.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
0
期刊最新文献
Multi-dataset Collaborative Learning for Liver Tumor Segmentation. A Modified Reference Scan Method for MR Image Inhomogeneity Correction. Muscle activation of lower limb during walking in elderly individuals with sarcopenia: A pilot study. A Multi-branch Attention-based Deep Learning Method for ALS Identification with sMRI Data. Narrowband-Enhanced Method for Improving Frequency Recognition in SSVEP-BCIs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1