BAPTA-based potentiometric polymer sensor: towards sensing inflammations and infections†

IF 6.1 3区 医学 Q1 MATERIALS SCIENCE, BIOMATERIALS Journal of Materials Chemistry B Pub Date : 2025-03-03 DOI:10.1039/D4TB02586E
Nikol Janić, Hanna Zhukouskaya, Peter Černoch, Jiří Pánek, Jan Svoboda, Milena Hajná, Alena Řezníčková, Elena Tomšík and Martin Hrubý
{"title":"BAPTA-based potentiometric polymer sensor: towards sensing inflammations and infections†","authors":"Nikol Janić, Hanna Zhukouskaya, Peter Černoch, Jiří Pánek, Jan Svoboda, Milena Hajná, Alena Řezníčková, Elena Tomšík and Martin Hrubý","doi":"10.1039/D4TB02586E","DOIUrl":null,"url":null,"abstract":"<p >Potentiometric ion sensors represent a significant subgroup of electrochemical sensors. In this study, we have developed a potentiometric sensor using an electrically conductive copolymer of 2,2′-bithiophene (BT) and 1,2-bis(<em>o</em>-aminophenoxy)ethane-<em>N</em>,<em>N</em>,<em>N</em>′,<em>N</em>′-tetraacetic acid (BAPTA) for the selective detection of Ca<small><sup>2+</sup></small> ions in extracellular interstitial fluids. The integration of BAPTA with its highly selective calcium chelating properties into a polymer matrix <em>via</em> electrochemical polymerization results in a sensitive conductive polymer layer that effectively detects the presence of calcium ions. This sensor aims at the early detection of inflammation or infection around implants because local calcium concentration is strongly elevated in interstitial fluid in such pathologies. The potentiometric study proves the incorporation of BAPTA into the polymer matrix was successful and its potential decreased upon calcium binding demonstrating the Nernstian behavior with a slope of approximately 20 ± 0.3 mV per decade in the concentration range from 0.1 mM to 1 mM. Moreover, the selectivity coefficient of –0.4 was measured by SSM and calculated from the Nicolsky–Eisenmann equation, which indicates selectivity towards Ca<small><sup>2+</sup></small> ions with respect to Mg<small><sup>2+</sup></small> ions.</p>","PeriodicalId":83,"journal":{"name":"Journal of Materials Chemistry B","volume":" 13","pages":" 4157-4165"},"PeriodicalIF":6.1000,"publicationDate":"2025-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/tb/d4tb02586e?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/tb/d4tb02586e","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Potentiometric ion sensors represent a significant subgroup of electrochemical sensors. In this study, we have developed a potentiometric sensor using an electrically conductive copolymer of 2,2′-bithiophene (BT) and 1,2-bis(o-aminophenoxy)ethane-N,N,N′,N′-tetraacetic acid (BAPTA) for the selective detection of Ca2+ ions in extracellular interstitial fluids. The integration of BAPTA with its highly selective calcium chelating properties into a polymer matrix via electrochemical polymerization results in a sensitive conductive polymer layer that effectively detects the presence of calcium ions. This sensor aims at the early detection of inflammation or infection around implants because local calcium concentration is strongly elevated in interstitial fluid in such pathologies. The potentiometric study proves the incorporation of BAPTA into the polymer matrix was successful and its potential decreased upon calcium binding demonstrating the Nernstian behavior with a slope of approximately 20 ± 0.3 mV per decade in the concentration range from 0.1 mM to 1 mM. Moreover, the selectivity coefficient of –0.4 was measured by SSM and calculated from the Nicolsky–Eisenmann equation, which indicates selectivity towards Ca2+ ions with respect to Mg2+ ions.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于bapta的电位聚合物传感器:用于感知炎症和感染。
电位离子传感器是电化学传感器中一个重要的分支。在这项研究中,我们开发了一种电位传感器,使用2,2'-双噻吩(BT)和1,2-二(邻氨基苯氧基)乙烷-N,N,N‘,N’-四乙酸(BAPTA)的导电共聚物,用于选择性检测细胞外间质液中的Ca2+离子。BAPTA具有高度选择性的钙螯合特性,通过电化学聚合将其整合到聚合物基体中,形成敏感的导电聚合物层,有效检测钙离子的存在。该传感器旨在早期检测植入物周围的炎症或感染,因为在这种病理中,间质液中的局部钙浓度会强烈升高。电势学研究证明BAPTA在聚合物基体中的结合是成功的,其电位在钙结合后下降,在0.1 mM至1 mM的浓度范围内显示出约20±0.3 mV / 10年的纳恩斯行为。此外,通过SSM测量并根据Nicolsky-Eisenmann方程计算的选择性系数为-0.4,表明相对于Mg2+离子,BAPTA对Ca2+离子有选择性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Materials Chemistry B
Journal of Materials Chemistry B MATERIALS SCIENCE, BIOMATERIALS-
CiteScore
11.50
自引率
4.30%
发文量
866
期刊介绍: Journal of Materials Chemistry A, B & C cover high quality studies across all fields of materials chemistry. The journals focus on those theoretical or experimental studies that report new understanding, applications, properties and synthesis of materials. Journal of Materials Chemistry A, B & C are separated by the intended application of the material studied. Broadly, applications in energy and sustainability are of interest to Journal of Materials Chemistry A, applications in biology and medicine are of interest to Journal of Materials Chemistry B, and applications in optical, magnetic and electronic devices are of interest to Journal of Materials Chemistry C.Journal of Materials Chemistry B is a Transformative Journal and Plan S compliant. Example topic areas within the scope of Journal of Materials Chemistry B are listed below. This list is neither exhaustive nor exclusive: Antifouling coatings Biocompatible materials Bioelectronics Bioimaging Biomimetics Biomineralisation Bionics Biosensors Diagnostics Drug delivery Gene delivery Immunobiology Nanomedicine Regenerative medicine & Tissue engineering Scaffolds Soft robotics Stem cells Therapeutic devices
期刊最新文献
A tumor-targeting gambogic acid-loaded nanovaccine reprograms the tumor microenvironment for enhanced cancer immunotherapy Toward reproducible SERS biosensing: analysing instability origins and mitigation approaches from sample preparation to detection Poly(γ-glutamic acid)-thickened PLLA microspheres with enhanced biocompatibility and efficacy in aged mice Controlled release of bone morphogenetic protein-2 improves motor function after traumatic brain injury in a rat model Effective inhibition of lung metastatic melanoma by pH-responsive lipopeptide/PLGA hybrid nanoparticles silencing PD-L1 with augmented suppression of the AKT/β-catenin pathway
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1