Pierre Bohec, Florian Dupuy, Victoria Tishkova, Valentine Seveau de Noray, Marie-Pierre Valignat, Olivier Theodoly
{"title":"Microvalve-based gradient generators to control flow-free, time zero and long-term conditions.","authors":"Pierre Bohec, Florian Dupuy, Victoria Tishkova, Valentine Seveau de Noray, Marie-Pierre Valignat, Olivier Theodoly","doi":"10.1039/d4lc00901k","DOIUrl":null,"url":null,"abstract":"<p><p>Experiments with gradients of soluble bioactive species have significantly advanced with microfluidic developments that enable cell observation and stringent control of environmental conditions. While some methodologies rely on flow to establish gradients, others opt for flow-free conditions, which is particularly beneficial for studying non-adherent and/or shear-sensitive cells. In flow-free devices, bioactive species diffuse either through resistive microchannels in microchannel-based devices, through a porous membrane in membrane-based devices, or through a hydrogel in gel-based devices. However, despite significant advancements over traditional methods such as Boyden chambers, these technologies have not been widely disseminated in biological laboratories, arguably due to entrenched practices and the intricate skills required for conducting microfluidic assays. Here, we developed microfluidic platforms integrating barriers with Quake-type pneumatic microvalves in place of microgrooves, membranes, or gels. One set of microvalves is used to maintain flow-free conditions and another set to regulate diffusion between a central channel housing the specimen of interest and sink/source reservoirs. This configuration enables stringent control over residual flows, precise spatial-temporal regulation of gradient formation, and exceptional gradient stability, maintained over extended periods <i>via</i> automated refilling of source and sink reservoirs. The gradient establishment was validated using fluorescent tracers with molar masses of 0.3-40 kDa, while cellular assays demonstrated the chemotactic response of primary human neutrophils swimming toward FMLP. The fabrication of microfluidic devices remains standardly demanding, but experimentation can be fully automated thanks to microvalves, making it accessible to non-expert users. This work presents a robust microfluidic approach for generating tunable gradients with stringent control over flow-free, time-zero, and long-term conditions and its automation and accessibility may promote adoption in academic and biomedical settings especially for non-adherent specimens.</p>","PeriodicalId":85,"journal":{"name":"Lab on a Chip","volume":" ","pages":""},"PeriodicalIF":6.1000,"publicationDate":"2025-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Lab on a Chip","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1039/d4lc00901k","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Experiments with gradients of soluble bioactive species have significantly advanced with microfluidic developments that enable cell observation and stringent control of environmental conditions. While some methodologies rely on flow to establish gradients, others opt for flow-free conditions, which is particularly beneficial for studying non-adherent and/or shear-sensitive cells. In flow-free devices, bioactive species diffuse either through resistive microchannels in microchannel-based devices, through a porous membrane in membrane-based devices, or through a hydrogel in gel-based devices. However, despite significant advancements over traditional methods such as Boyden chambers, these technologies have not been widely disseminated in biological laboratories, arguably due to entrenched practices and the intricate skills required for conducting microfluidic assays. Here, we developed microfluidic platforms integrating barriers with Quake-type pneumatic microvalves in place of microgrooves, membranes, or gels. One set of microvalves is used to maintain flow-free conditions and another set to regulate diffusion between a central channel housing the specimen of interest and sink/source reservoirs. This configuration enables stringent control over residual flows, precise spatial-temporal regulation of gradient formation, and exceptional gradient stability, maintained over extended periods via automated refilling of source and sink reservoirs. The gradient establishment was validated using fluorescent tracers with molar masses of 0.3-40 kDa, while cellular assays demonstrated the chemotactic response of primary human neutrophils swimming toward FMLP. The fabrication of microfluidic devices remains standardly demanding, but experimentation can be fully automated thanks to microvalves, making it accessible to non-expert users. This work presents a robust microfluidic approach for generating tunable gradients with stringent control over flow-free, time-zero, and long-term conditions and its automation and accessibility may promote adoption in academic and biomedical settings especially for non-adherent specimens.
期刊介绍:
Lab on a Chip is the premiere journal that publishes cutting-edge research in the field of miniaturization. By their very nature, microfluidic/nanofluidic/miniaturized systems are at the intersection of disciplines, spanning fundamental research to high-end application, which is reflected by the broad readership of the journal. Lab on a Chip publishes two types of papers on original research: full-length research papers and communications. Papers should demonstrate innovations, which can come from technical advancements or applications addressing pressing needs in globally important areas. The journal also publishes Comments, Reviews, and Perspectives.