Speckle Denoising of Dynamic Contrast-enhanced Ultrasound using Low-rank Tensor Decomposition.

Metin Calis, Massimo Mischi, Alle-Jan van der Veen, Borbala Hunyadi
{"title":"Speckle Denoising of Dynamic Contrast-enhanced Ultrasound using Low-rank Tensor Decomposition.","authors":"Metin Calis, Massimo Mischi, Alle-Jan van der Veen, Borbala Hunyadi","doi":"10.1109/TMI.2025.3551660","DOIUrl":null,"url":null,"abstract":"<p><p>Dynamic contrast-enhanced ultrasound (DCEUS) is an imaging modality for assessing microvascular perfusion and dispersion kinetics. However, the presence of speckle noise may hamper the quantitative analysis of the contrast kinetics. Common speckle denoising techniques based on low-rank approximations typically model the speckle noise as white Gaussian noise (WGN) after the log transformation and apply matrix-based algorithms. We address the high dimensionality of the 4D DCEUS data and apply low-rank tensor decomposition techniques to denoise speckles. Although there are many tensor decompositions that can describe low rankness, we limit our research to multilinear rank and tubal rank. We introduce a gradient-based extension of the multilinear singular value decomposition to model low multilinear rankness, assuming that the log-transformed speckle noise follows a Fisher-tippet distribution. In addition, we apply an algorithm based on tensor singular value decomposition to model low tubal rankness, assuming that the log-transformed speckle noise is WGN with sparse outliers. The effectiveness of the methods is evaluated through simulations and phantom studies. Additionally, the tensor-based algorithms' real-world performance is assessed using DCEUS prostate recordings. Comparative analyses with existing DCEUS denoising literature are conducted, and the algorithms' capabilities are showcased in the context of prostate cancer classification. The addition of Fisher-tippet distribution did not improve the results of tr-MLSVD in the in vivo case. However, most cancer markers are better distinguishable when using a tensor denoising technique than state-of-the-art approaches.</p>","PeriodicalId":94033,"journal":{"name":"IEEE transactions on medical imaging","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TMI.2025.3551660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Dynamic contrast-enhanced ultrasound (DCEUS) is an imaging modality for assessing microvascular perfusion and dispersion kinetics. However, the presence of speckle noise may hamper the quantitative analysis of the contrast kinetics. Common speckle denoising techniques based on low-rank approximations typically model the speckle noise as white Gaussian noise (WGN) after the log transformation and apply matrix-based algorithms. We address the high dimensionality of the 4D DCEUS data and apply low-rank tensor decomposition techniques to denoise speckles. Although there are many tensor decompositions that can describe low rankness, we limit our research to multilinear rank and tubal rank. We introduce a gradient-based extension of the multilinear singular value decomposition to model low multilinear rankness, assuming that the log-transformed speckle noise follows a Fisher-tippet distribution. In addition, we apply an algorithm based on tensor singular value decomposition to model low tubal rankness, assuming that the log-transformed speckle noise is WGN with sparse outliers. The effectiveness of the methods is evaluated through simulations and phantom studies. Additionally, the tensor-based algorithms' real-world performance is assessed using DCEUS prostate recordings. Comparative analyses with existing DCEUS denoising literature are conducted, and the algorithms' capabilities are showcased in the context of prostate cancer classification. The addition of Fisher-tippet distribution did not improve the results of tr-MLSVD in the in vivo case. However, most cancer markers are better distinguishable when using a tensor denoising technique than state-of-the-art approaches.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
DenseFormer-MoE: A Dense Transformer Foundation Model with Mixture of Experts for Multi-Task Brain Image Analysis. Speckle Denoising of Dynamic Contrast-enhanced Ultrasound using Low-rank Tensor Decomposition. WeakMedSAM: Weakly-Supervised Medical Image Segmentation via SAM with Sub-Class Exploration and Prompt Affinity Mining. Table of Contents Table of Contents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1