Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.

IF 1.8 Q3 MEDICAL LABORATORY TECHNOLOGY Journal of Applied Laboratory Medicine Pub Date : 2025-03-19 DOI:10.1093/jalm/jfaf009
Noel Stierlin, Andreas Hemmerle, Harald Renz, Lorenz Risch, Martin Risch
{"title":"Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.","authors":"Noel Stierlin, Andreas Hemmerle, Harald Renz, Lorenz Risch, Martin Risch","doi":"10.1093/jalm/jfaf009","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Maintaining blood sample integrity is essential for accurate laboratory diagnostics. The hemolytic, lipemic, and icteric (HIL) indices are critical markers of sample quality, detecting common preanalytical interferences such as hemolysis, lipemia, and icterus. Drone technology offers a novel transport method for medical logistics, particularly in remote or underserved regions. This study assessed the stability of HIL indices in blood samples transported by drone.</p><p><strong>Methods: </strong>Twenty-five samples each of serum, EDTA whole blood, lithium-heparin plasma, and citrate plasma were collected from healthy volunteers using standard venipuncture techniques. Serum samples were collected in gel separator tubes. Samples were transported unprocessed using a rotor-type hybrid drone (Jedsy Glider) over a 25-kilometer route. Temperature and vibration were monitored during flight using data loggers and accelerometers. HIL indices were measured preflight and postflight using a Roche Cobas 6000 system. Paired t-tests assessed significant changes (P < 0.05).</p><p><strong>Results: </strong>No statistically significant differences were observed in the HIL indices preflight and postflight for all blood sample types. For serum samples, the hemolytic index decreased slightly from 9.60 to 9.45 (P = 0.19), with negligible changes in lipemic and icteric indices. Similar stability was observed for EDTA whole blood, lithium-heparin plasma, and citrate plasma.</p><p><strong>Conclusions: </strong>Drone transport is a viable alternative for blood sample logistics, preserving HIL index stability across various sample types. These findings underscore the potential of drones to enhance healthcare logistics in remote or underserved environments.</p><p><strong>Research ethics: </strong>This study was conducted as a quality assurance project for the Institute of Clinical Chemistry at Dr. Risch, Buchs, Switzerland. The Ethics Committee Ostschweiz reviewed the study under BASEC-ID Req-2024-01510 and determined that it does not fall within the scope of the Swiss Human Research Act and therefore does not require formal ethics committee approval. This determination was based on the project's designation as a quality assurance initiative rather than a human research study. As per the committee's guidance, data protection and confidentiality were strictly maintained throughout the study, ensuring compliance with all relevant legal and institutional requirements.</p>","PeriodicalId":46361,"journal":{"name":"Journal of Applied Laboratory Medicine","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jalm/jfaf009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Maintaining blood sample integrity is essential for accurate laboratory diagnostics. The hemolytic, lipemic, and icteric (HIL) indices are critical markers of sample quality, detecting common preanalytical interferences such as hemolysis, lipemia, and icterus. Drone technology offers a novel transport method for medical logistics, particularly in remote or underserved regions. This study assessed the stability of HIL indices in blood samples transported by drone.

Methods: Twenty-five samples each of serum, EDTA whole blood, lithium-heparin plasma, and citrate plasma were collected from healthy volunteers using standard venipuncture techniques. Serum samples were collected in gel separator tubes. Samples were transported unprocessed using a rotor-type hybrid drone (Jedsy Glider) over a 25-kilometer route. Temperature and vibration were monitored during flight using data loggers and accelerometers. HIL indices were measured preflight and postflight using a Roche Cobas 6000 system. Paired t-tests assessed significant changes (P < 0.05).

Results: No statistically significant differences were observed in the HIL indices preflight and postflight for all blood sample types. For serum samples, the hemolytic index decreased slightly from 9.60 to 9.45 (P = 0.19), with negligible changes in lipemic and icteric indices. Similar stability was observed for EDTA whole blood, lithium-heparin plasma, and citrate plasma.

Conclusions: Drone transport is a viable alternative for blood sample logistics, preserving HIL index stability across various sample types. These findings underscore the potential of drones to enhance healthcare logistics in remote or underserved environments.

Research ethics: This study was conducted as a quality assurance project for the Institute of Clinical Chemistry at Dr. Risch, Buchs, Switzerland. The Ethics Committee Ostschweiz reviewed the study under BASEC-ID Req-2024-01510 and determined that it does not fall within the scope of the Swiss Human Research Act and therefore does not require formal ethics committee approval. This determination was based on the project's designation as a quality assurance initiative rather than a human research study. As per the committee's guidance, data protection and confidentiality were strictly maintained throughout the study, ensuring compliance with all relevant legal and institutional requirements.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Applied Laboratory Medicine
Journal of Applied Laboratory Medicine MEDICAL LABORATORY TECHNOLOGY-
CiteScore
3.70
自引率
5.00%
发文量
137
期刊最新文献
Acute Sodium Fluctuation in Altered Consciousness: A Puzzle or a Key to Diagnosis? Commentary on Acute Sodium Fluctuation in Altered Consciousness: A Puzzle or a Key to Diagnosis? An Unexpected Cause of Rhabdomyolysis. Commentary on An Unexpected Cause of Rhabdomyolysis. Stability of Hemolytic, Lipemic, and Icteric Indices in Blood Samples Transported by Drone: A Focused Report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1