Determination of oxygen tension on rabbit corneas under contact lenses.

H Ichijima, T Hayashi, S Mitsunaga, H Hamano
{"title":"Determination of oxygen tension on rabbit corneas under contact lenses.","authors":"H Ichijima,&nbsp;T Hayashi,&nbsp;S Mitsunaga,&nbsp;H Hamano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine oxygen tension (PO2) on rabbit corneas beneath rigid gas permeable (RGP), hydrogel, and silicone elastomer lenses under open- and closed-eye conditions and to demonstrate the relationship between PO2 and overnight corneal swelling response in the rabbit model.</p><p><strong>Methods: </strong>An improved PO2 monitoring system (PO-2080) with a platinum-micro-wire-electrode was used to measure PO2. An ultrasonic pachymeter (DGH-2000) was used to measure corneal thickness after overnight wear.</p><p><strong>Results: </strong>The relationship between PO2 and oxygen transmissibility (Dk/ L) of the contact lens was linear for Dk/L between 0 and 70 x 10(-9) (cm/ sec)(mLO2/mL x mmHg). For Dk/L greater than 70 x 10(-9), PO2 gradually reached a plateau at 120 mmHg for open-eye conditions and 20 mmHg for closed-eye conditions. PO2 was inversely related to the overnight corneal swelling, ranging from 5.1% swelling at PO2 113.5/17.5 mmHg (open/closed-eye) for a hyper Dk/L lens (125 x 10(-9)) to 15.1% swelling at PO2 10.4/5.1 mmHg for a low Dk/L lens (11.5 x 10(-9)).</p><p><strong>Conclusions: </strong>Polarographic determination of PO2 provides reliable information about the amount of oxygen available to the cornea under a lens for both open-eye and closed-eye conditions. The data demonstrate that it is not possible to achieve normal oxygen levels with contact lens wear, even when hyper Dk/L lenses are worn.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"24 4","pages":"220-6"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To determine oxygen tension (PO2) on rabbit corneas beneath rigid gas permeable (RGP), hydrogel, and silicone elastomer lenses under open- and closed-eye conditions and to demonstrate the relationship between PO2 and overnight corneal swelling response in the rabbit model.

Methods: An improved PO2 monitoring system (PO-2080) with a platinum-micro-wire-electrode was used to measure PO2. An ultrasonic pachymeter (DGH-2000) was used to measure corneal thickness after overnight wear.

Results: The relationship between PO2 and oxygen transmissibility (Dk/ L) of the contact lens was linear for Dk/L between 0 and 70 x 10(-9) (cm/ sec)(mLO2/mL x mmHg). For Dk/L greater than 70 x 10(-9), PO2 gradually reached a plateau at 120 mmHg for open-eye conditions and 20 mmHg for closed-eye conditions. PO2 was inversely related to the overnight corneal swelling, ranging from 5.1% swelling at PO2 113.5/17.5 mmHg (open/closed-eye) for a hyper Dk/L lens (125 x 10(-9)) to 15.1% swelling at PO2 10.4/5.1 mmHg for a low Dk/L lens (11.5 x 10(-9)).

Conclusions: Polarographic determination of PO2 provides reliable information about the amount of oxygen available to the cornea under a lens for both open-eye and closed-eye conditions. The data demonstrate that it is not possible to achieve normal oxygen levels with contact lens wear, even when hyper Dk/L lenses are worn.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
隐形眼镜下兔角膜氧张力的测定。
目的:测定兔角膜氧张力(PO2)在开放和闭眼条件下在硬质透气性(RGP)、水凝胶和硅弹性体透镜下的变化,并在兔模型中证明PO2与夜间角膜肿胀反应的关系。方法:采用改进的PO2监测系统(PO-2080)和铂微丝电极测量PO2。超声厚度计(DGH-2000)测量过夜磨损后角膜厚度。结果:PO2与隐形眼镜的氧传递率(Dk/ L)呈线性关系,Dk/L在0 ~ 70 × 10(-9) (cm/ sec)(mLO2/mL × mmHg)之间。当Dk/L大于70 × 10(-9)时,PO2在睁眼和闭眼条件下逐渐达到平台值,分别为120mmhg和20mmhg。PO2与夜间角膜肿胀呈负相关,对于高Dk/L晶体(125 × 10(-9)), PO2 113.5/17.5 mmHg(睁眼/闭眼)时的肿胀为5.1%,对于低Dk/L晶体(11.5 × 10(-9)), PO2 10.4/5.1 mmHg时的肿胀为15.1%。结论:极谱法测定PO2提供了关于睁眼和闭眼条件下角膜晶状体下可用氧气量的可靠信息。数据表明,即使戴着超Dk/L隐形眼镜,也不可能达到正常的氧气水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Microbiologic evaluation of frequent-replacement soft contact lenses. Objective assessment of aberrations induced by multifocal contact lenses in vivo. Initial selection of soft contact lenses based on corneal characteristics. Retrospective safety study of the herrick lacrimal plug: a device used to occlude the lacrimal canaliculus. Lid-wiper epitheliopathy and dry-eye symptoms in contact lens wearers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1