首页 > 最新文献

The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc最新文献

英文 中文
Lid-wiper epitheliopathy and dry-eye symptoms in contact lens wearers. 隐形眼镜佩戴者的湿性上皮病和干眼症状。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000029344.37847.5A
Donald R Korb, Jack V Greiner, John P Herman, Eric Hebert, Victor M Finnemore, Joan M Exford, Thomas Glonek, Mary Catherine Olson

Purpose: To evaluate whether dry-eye symptoms are associated with epitheliopathy of that portion of the upper eyelid marginal conjunctiva-the lid wiper-that wipes the ocular, or contact lens surface, during blinking.

Methods: Subjects were divided into two groups based on the presence or absence of dry-eye symptoms. The lid wiper of asymptomatic (n=75) and symptomatic (n=30) soft contact lens wearers was examined, following the instillation of fluorescein and rose bengal dyes. Lid-wiper staining was graded zero to 3.

Results: Eighty percent of the symptomatic subjects displayed lid-wiper staining compared to 13% of the asymptomatic subjects. The difference in staining between the two groups was significant (P<0.0001). Of the symptomatic subjects, 20% showed no staining; 26.6%, grade 1 staining; 36.6%, grade 2; and 16.6% showed grade 3 staining. Of the asymptomatic subjects, 87% exhibited no staining; 9%, grade 1 staining; 3%, grade 2; and 1% showed grade 3 staining.

Conclusions: This study describes a new clinical condition, lid-wiper epitheliopathy, an alteration of the epithelium of that portion of the marginal conjunctiva of the upper eyelid that wipes the ocular surface, diagnosed by staining with fluorescein and rose bengal dyes.

目的:评估干眼症状是否与眨眼时擦眼或隐形眼镜表面的上眼睑边缘结膜部分的上皮病变有关。方法:根据有无干眼症状将受试者分为两组。对无症状(n=75)和有症状(n=30)软性隐形眼镜佩戴者的擦盖器进行检查,随后滴注荧光素和孟加拉玫瑰染料。刷盖染色分为0 ~ 3级。结果:80%的有症状的受试者显示了擦盖染色,而无症状的受试者为13%。结论:本研究描述了一种新的临床症状——擦眼睑上皮病,即上眼睑边缘结膜擦拭眼表部分的上皮改变,用荧光素和玫瑰红染料染色诊断。
{"title":"Lid-wiper epitheliopathy and dry-eye symptoms in contact lens wearers.","authors":"Donald R Korb,&nbsp;Jack V Greiner,&nbsp;John P Herman,&nbsp;Eric Hebert,&nbsp;Victor M Finnemore,&nbsp;Joan M Exford,&nbsp;Thomas Glonek,&nbsp;Mary Catherine Olson","doi":"10.1097/01.ICL.0000029344.37847.5A","DOIUrl":"https://doi.org/10.1097/01.ICL.0000029344.37847.5A","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate whether dry-eye symptoms are associated with epitheliopathy of that portion of the upper eyelid marginal conjunctiva-the lid wiper-that wipes the ocular, or contact lens surface, during blinking.</p><p><strong>Methods: </strong>Subjects were divided into two groups based on the presence or absence of dry-eye symptoms. The lid wiper of asymptomatic (n=75) and symptomatic (n=30) soft contact lens wearers was examined, following the instillation of fluorescein and rose bengal dyes. Lid-wiper staining was graded zero to 3.</p><p><strong>Results: </strong>Eighty percent of the symptomatic subjects displayed lid-wiper staining compared to 13% of the asymptomatic subjects. The difference in staining between the two groups was significant (P<0.0001). Of the symptomatic subjects, 20% showed no staining; 26.6%, grade 1 staining; 36.6%, grade 2; and 16.6% showed grade 3 staining. Of the asymptomatic subjects, 87% exhibited no staining; 9%, grade 1 staining; 3%, grade 2; and 1% showed grade 3 staining.</p><p><strong>Conclusions: </strong>This study describes a new clinical condition, lid-wiper epitheliopathy, an alteration of the epithelium of that portion of the marginal conjunctiva of the upper eyelid that wipes the ocular surface, diagnosed by staining with fluorescein and rose bengal dyes.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"211-6"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077621","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 201
The relationship between long-term contact lens wear and corneal thickness. 长期隐形眼镜佩戴与角膜厚度的关系。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000029403.04042.33
Elliott H Myrowitz, Michelle Melia, Terrence P O'Brien

Purpose: The purpose of this study is to assess the effects of long-term contact lens wear on corneal thickness and to compare differences based on rigid versus soft lens material.

Methods: This analysis included scanning slit topographic imaging (Orbscan, Bausch & Lomb, Rochester, NY) performed on 124 consecutive patients (248 eyes), who underwent comprehensive evaluations in consideration of refractive surgery by one surgeon.

Results: Sixty-two 62 patients (124 eyes) who had not previously worn contact lenses had a least-squares mean pachymetry of 546.4 microm +/-3.5 SE. Thirty-nine patients (78 eyes) who had previously worn soft contact lenses for an average of 16 years had a least-squares mean pachymetry of 543.2 microm +/-3.8 SE. Twenty-three patients (46 eyes) who had worn rigid contact lenses for an average of 19 years had a least-squares mean pachymetry of 509.4 microm +/-6.9 SE. Mean pachymetry differed significantly between eyes wearing rigid lenses versus no lenses (P<0.0001) and between eyes wearing rigid lenses versus soft lenses (P=0.0002).

Conclusion: Long-term rigid contact lens wear is associated with a decrease in the average central-corneal thickness (CCT) by an average of 37 microm, in this group of otherwise healthy eyes, compared to no contact lens wear. Long-term soft contact lens wear did not appear to significantly change corneal thickness compared to no contact lens wear. Caution should be exercised when screening patients with a history of long-term rigid contact lens wear for possible excimer-laser photoablative correction.

目的:本研究的目的是评估长期佩戴隐形眼镜对角膜厚度的影响,并比较基于硬晶状体和软晶状体材料的差异。方法:本分析包括124例连续患者(248只眼睛)的扫描狭缝地形成像(Orbscan, Bausch & Lomb, Rochester, NY),这些患者接受了一名外科医生考虑屈光手术的综合评估。结果:62 62例(124只眼)未配戴隐形眼镜的患者,其最小二乘平均厚度为546.4微米+/-3.5 SE。平均配戴软性隐形眼镜16年的39例患者(78只眼)的最小二乘平均厚度为543.2 μ m +/-3.8 SE。23例患者(46只眼)平均佩戴硬性隐形眼镜19年,其最小二乘平均视厚测量值为509.4微米+/-6.9 SE。佩戴硬性隐形眼镜和不佩戴硬性隐形眼镜的眼睛的平均角膜厚度差异显著(结论:在这组其他方面健康的眼睛中,与不佩戴隐形眼镜相比,长期佩戴硬性隐形眼镜与平均角膜中央厚度(CCT)下降平均37微米有关。与不佩戴隐形眼镜相比,长期佩戴软性隐形眼镜对角膜厚度没有明显的影响。在筛选有长期佩戴硬性隐形眼镜病史的患者时,应谨慎进行准分子激光光消融矫正。
{"title":"The relationship between long-term contact lens wear and corneal thickness.","authors":"Elliott H Myrowitz,&nbsp;Michelle Melia,&nbsp;Terrence P O'Brien","doi":"10.1097/01.ICL.0000029403.04042.33","DOIUrl":"https://doi.org/10.1097/01.ICL.0000029403.04042.33","url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study is to assess the effects of long-term contact lens wear on corneal thickness and to compare differences based on rigid versus soft lens material.</p><p><strong>Methods: </strong>This analysis included scanning slit topographic imaging (Orbscan, Bausch & Lomb, Rochester, NY) performed on 124 consecutive patients (248 eyes), who underwent comprehensive evaluations in consideration of refractive surgery by one surgeon.</p><p><strong>Results: </strong>Sixty-two 62 patients (124 eyes) who had not previously worn contact lenses had a least-squares mean pachymetry of 546.4 microm +/-3.5 SE. Thirty-nine patients (78 eyes) who had previously worn soft contact lenses for an average of 16 years had a least-squares mean pachymetry of 543.2 microm +/-3.8 SE. Twenty-three patients (46 eyes) who had worn rigid contact lenses for an average of 19 years had a least-squares mean pachymetry of 509.4 microm +/-6.9 SE. Mean pachymetry differed significantly between eyes wearing rigid lenses versus no lenses (P<0.0001) and between eyes wearing rigid lenses versus soft lenses (P=0.0002).</p><p><strong>Conclusion: </strong>Long-term rigid contact lens wear is associated with a decrease in the average central-corneal thickness (CCT) by an average of 37 microm, in this group of otherwise healthy eyes, compared to no contact lens wear. Long-term soft contact lens wear did not appear to significantly change corneal thickness compared to no contact lens wear. Caution should be exercised when screening patients with a history of long-term rigid contact lens wear for possible excimer-laser photoablative correction.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"217-20"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077622","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 39
Ocular manifestations of electrical injury: a case report and review of the literature. 电损伤的眼部表现:1例报告及文献复习。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000032345.79593.24
Barbara K Miller, Michael H Goldstein, Ramin Monshizadeh, Homayoun Tabandeh, M Tariq Bhatti

Purpose: To report a case of electrical shock resulting in multiple ocular manifestations, including anisocoria, acute bilateral iritis, bilateral cataracts, and macular cyst formation, and to provide a review of the literature on electrically induced ocular injuries.

Methods: Case report and review of the literature.

Results: The case presented demonstrates a sequential occurrence of anisocoria, bilateral cataract formation, iritis, and macular cyst formation, with resolution following medical and surgical treatment.

Conclusions: Electrically induced injuries can have many ocular manifestations that may occur simultaneously or sequentially, occasionally occurring later than the inciting event. The most common ocular finding is cataract formation.

摘要目的:报告一例电休克导致的多重眼部表现,包括眼内斜视、急性双侧虹膜炎、双侧白内障和黄斑囊肿形成,并对电致眼部损伤的文献进行回顾。方法:病例报告和文献复习。结果:本病例表现为连续发生的多晶眼、双侧白内障形成、虹膜炎和黄斑囊肿形成,经药物和手术治疗后得到解决。结论:电致损伤可有多种眼部表现,可同时发生或依次发生,偶尔发生于刺激事件之后。最常见的眼部表现是白内障的形成。
{"title":"Ocular manifestations of electrical injury: a case report and review of the literature.","authors":"Barbara K Miller,&nbsp;Michael H Goldstein,&nbsp;Ramin Monshizadeh,&nbsp;Homayoun Tabandeh,&nbsp;M Tariq Bhatti","doi":"10.1097/01.ICL.0000032345.79593.24","DOIUrl":"https://doi.org/10.1097/01.ICL.0000032345.79593.24","url":null,"abstract":"<p><strong>Purpose: </strong>To report a case of electrical shock resulting in multiple ocular manifestations, including anisocoria, acute bilateral iritis, bilateral cataracts, and macular cyst formation, and to provide a review of the literature on electrically induced ocular injuries.</p><p><strong>Methods: </strong>Case report and review of the literature.</p><p><strong>Results: </strong>The case presented demonstrates a sequential occurrence of anisocoria, bilateral cataract formation, iritis, and macular cyst formation, with resolution following medical and surgical treatment.</p><p><strong>Conclusions: </strong>Electrically induced injuries can have many ocular manifestations that may occur simultaneously or sequentially, occasionally occurring later than the inciting event. The most common ocular finding is cataract formation.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"224-7"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077624","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 34
Mycobacterium chelonae keratitis associated with soft contact lens wear. 与软性隐形眼镜佩戴相关的龟分枝杆菌角膜炎。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000032344.00995.5C
Monika A Malecha, Donald J Doughman

Purpose: To report a case of Mycobacterium chelonae keratitis associated with soft contact lens wear.

Methods: A 17-year-old boy who wore frequent replacement soft contact lenses developed keratitis in the right eye. There was no history of trauma to the right eye. The patient was treated initially with topical ciprofloxacin but without improvement. On presentation, visual acuity in his right eye was 20/40. A Gram-stained scraping of the corneal infiltrate revealed beaded filamentous rods, and the organisms were acid-fast positive. The patient's right eye was treated with intensive topical amikacin, 20 mg/mL, and 10 % sulfacetamide. Eventually, Mycobacterium chelonae was cultured on Sabourard's agar, topical sulfacetamide was stopped, and amikacin was continued.

Results: The patient's keratitis responded well to amikacin and resolved over a period of 4 weeks. Visual acuity in the right eye improved to 20/25.

Conclusions: Mycobacterium chelonae is a rare cause of keratitis in soft contact lens wearers. We have identified fewer than five cases of Mycobacterium chelonae keratitis associated with soft contact lenses in the literature. Prompt and accurate diagnosis of the organism using comeal scraping can lead to appropriate therapy and resolution of the keratitis.

目的:报告1例与软性隐形眼镜配戴相关的龟分枝杆菌角膜炎。方法:1例17岁男孩因频繁配戴软性隐形眼镜,右眼出现角膜炎。右眼没有外伤史。患者最初使用局部环丙沙星治疗,但没有改善。入院时,右眼视力为20/40。革兰氏染色刮拭角膜浸润,可见珠状丝状杆状物,细菌呈抗酸阳性。患者右眼给予阿米卡星20mg /mL、10%磺胺乙酰胺强化局部治疗。最后,在Sabourard琼脂上培养chelon分枝杆菌,停用磺胺乙酰胺,继续使用阿米卡星。结果:患者角膜炎对阿米卡星反应良好,并在4周内消退。右眼视力改善至20/25。结论:龟分枝杆菌是引起软性隐形眼镜佩戴者角膜炎的罕见原因。在文献中,我们发现少于5例与软性隐形眼镜相关的龟分枝杆菌角膜炎。及时和准确的诊断,使用角膜刮拭可以导致适当的治疗和解决角膜炎的有机体。
{"title":"Mycobacterium chelonae keratitis associated with soft contact lens wear.","authors":"Monika A Malecha,&nbsp;Donald J Doughman","doi":"10.1097/01.ICL.0000032344.00995.5C","DOIUrl":"https://doi.org/10.1097/01.ICL.0000032344.00995.5C","url":null,"abstract":"<p><strong>Purpose: </strong>To report a case of Mycobacterium chelonae keratitis associated with soft contact lens wear.</p><p><strong>Methods: </strong>A 17-year-old boy who wore frequent replacement soft contact lenses developed keratitis in the right eye. There was no history of trauma to the right eye. The patient was treated initially with topical ciprofloxacin but without improvement. On presentation, visual acuity in his right eye was 20/40. A Gram-stained scraping of the corneal infiltrate revealed beaded filamentous rods, and the organisms were acid-fast positive. The patient's right eye was treated with intensive topical amikacin, 20 mg/mL, and 10 % sulfacetamide. Eventually, Mycobacterium chelonae was cultured on Sabourard's agar, topical sulfacetamide was stopped, and amikacin was continued.</p><p><strong>Results: </strong>The patient's keratitis responded well to amikacin and resolved over a period of 4 weeks. Visual acuity in the right eye improved to 20/25.</p><p><strong>Conclusions: </strong>Mycobacterium chelonae is a rare cause of keratitis in soft contact lens wearers. We have identified fewer than five cases of Mycobacterium chelonae keratitis associated with soft contact lenses in the literature. Prompt and accurate diagnosis of the organism using comeal scraping can lead to appropriate therapy and resolution of the keratitis.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"228-30"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22078154","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 12
Time to resolution of contact lens-induced corneal warpage prior to refractive surgery. 屈光手术前隐形眼镜引起的角膜翘曲的解决时间。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000018042.02034.AB
Xiaohong Wang, James P McCulley, R Wayne Bowman, H Dwight Cavanagh

Purpose: To evaluate the resolution of contact lens-induced corneal warpage before keratorefractive surgery.

Methods: We prospectively studied the eyes of 165 consecutive contact lens-wearing patients evaluated for keratorefractive surgery. Significant contact lens-induced corneal warpage was detected by comeal topography in 20 eyes of 11 patients. Manifested refraction, keratometry, and cornea topography were subsequently recorded during weekly or biweekly reevaluations and were compared with previous measurements for stability. Effects of age, sex, type, and duration of contact-lens wear and the recovery time period to stabilization were analyzed.

Results: Overall, a 12% incidence of significant contact lens-induced corneal warpage was found. In patients demonstrating lens-associated warpage, the mean duration of prior contact lens wear was 21.2 years (range 10 to 30 years); lens use included daily wear soft (n=2), extended-wear soft (n=6), toric (n=4), and rigid gas-permeable contact lenses (n=8). Up to 3.0 diopter (D) refractive and 2.5D keratometric shifts accompanied by significant topography pattern differences were observed. The average recovery time for stabilization of refraction, keratometry (change within +/- 0.5D), and topography pattern was 7.8+/-6.7 weeks (range 1 to 20 weeks). Recovery rates differed between the lens types: soft extended-wear 11.6+/-8.5 weeks, soft toric lens 5.5+/-4.9 weeks, soft daily wear 2.5+/-2.1 weeks, and rigid gas-permeable 8.8+/-6.8 weeks.

Conclusion: We observed a 12% incidence of significant contact lens-induced corneal warpage in patients undergoing evaluation for keratorefractive surgery. Warpage occurred with all types of contact lens wear but resolved at different rates. To optimize the quality and predictability of keratorefractive procedures, an appropriate waiting period is necessary for contact lens-induced corneal warpage to stabilize. We suggest that resolution of corneal warpage be documented by stable serial manifested refractions, keratometry, and corneal topographic patterns before scheduling patients for keratorefractive surgery.

目的:探讨角膜屈光手术前隐形眼镜性角膜翘曲的解决方法。方法:对165例接受角膜屈光手术的连续佩戴隐形眼镜患者的眼睛进行前瞻性研究。11例患者共20眼,角膜地形图检查出明显的接触镜性角膜翘曲。随后在每周或每两周的重新评估中记录明显的屈光、角膜测量和角膜地形图,并与之前的测量结果进行比较。分析年龄、性别、类型、佩戴时间及恢复时间对稳定的影响。结果:总体而言,发现了12%的明显的隐形眼镜引起的角膜翘曲发生率。在表现出隐形眼镜相关翘曲的患者中,以前佩戴隐形眼镜的平均持续时间为21.2年(范围为10至30年);使用的隐形眼镜包括日常佩戴软隐形眼镜(n=2)、延长佩戴软隐形眼镜(n=6)、环面隐形眼镜(n=4)和硬性透气性隐形眼镜(n=8)。观察到高达3.0屈光度(D)和2.5D角膜形变,并伴有明显的地形模式差异。屈光、角膜测量(+/- 0.5D内的变化)和地形模式稳定的平均恢复时间为7.8+/-6.7周(范围1至20周)。不同类型晶状体的恢复率不同:软性长期磨损11.6+/-8.5周,软性环面晶状体5.5+/-4.9周,软性日常磨损2.5+/-2.1周,硬性透气性晶状体8.8+/-6.8周。结论:我们观察到,在接受角膜屈光手术评估的患者中,有12%的患者出现明显的接触镜引起的角膜翘曲。所有类型的隐形眼镜佩戴都会发生翘曲,但解决的速度不同。为了优化角膜屈光手术的质量和可预见性,需要适当的等待时间来稳定隐形眼镜引起的角膜翘曲。我们建议在安排患者进行角膜屈光手术之前,通过稳定的一系列表现的屈光,角膜测量和角膜地形图模式来记录角膜翘曲的解决。
{"title":"Time to resolution of contact lens-induced corneal warpage prior to refractive surgery.","authors":"Xiaohong Wang,&nbsp;James P McCulley,&nbsp;R Wayne Bowman,&nbsp;H Dwight Cavanagh","doi":"10.1097/01.ICL.0000018042.02034.AB","DOIUrl":"https://doi.org/10.1097/01.ICL.0000018042.02034.AB","url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the resolution of contact lens-induced corneal warpage before keratorefractive surgery.</p><p><strong>Methods: </strong>We prospectively studied the eyes of 165 consecutive contact lens-wearing patients evaluated for keratorefractive surgery. Significant contact lens-induced corneal warpage was detected by comeal topography in 20 eyes of 11 patients. Manifested refraction, keratometry, and cornea topography were subsequently recorded during weekly or biweekly reevaluations and were compared with previous measurements for stability. Effects of age, sex, type, and duration of contact-lens wear and the recovery time period to stabilization were analyzed.</p><p><strong>Results: </strong>Overall, a 12% incidence of significant contact lens-induced corneal warpage was found. In patients demonstrating lens-associated warpage, the mean duration of prior contact lens wear was 21.2 years (range 10 to 30 years); lens use included daily wear soft (n=2), extended-wear soft (n=6), toric (n=4), and rigid gas-permeable contact lenses (n=8). Up to 3.0 diopter (D) refractive and 2.5D keratometric shifts accompanied by significant topography pattern differences were observed. The average recovery time for stabilization of refraction, keratometry (change within +/- 0.5D), and topography pattern was 7.8+/-6.7 weeks (range 1 to 20 weeks). Recovery rates differed between the lens types: soft extended-wear 11.6+/-8.5 weeks, soft toric lens 5.5+/-4.9 weeks, soft daily wear 2.5+/-2.1 weeks, and rigid gas-permeable 8.8+/-6.8 weeks.</p><p><strong>Conclusion: </strong>We observed a 12% incidence of significant contact lens-induced corneal warpage in patients undergoing evaluation for keratorefractive surgery. Warpage occurred with all types of contact lens wear but resolved at different rates. To optimize the quality and predictability of keratorefractive procedures, an appropriate waiting period is necessary for contact lens-induced corneal warpage to stabilize. We suggest that resolution of corneal warpage be documented by stable serial manifested refractions, keratometry, and corneal topographic patterns before scheduling patients for keratorefractive surgery.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"169-71"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077665","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 58
PRK-pTK as a treatment for a patient with Thygeson's superficial punctate keratopathy. PRK-pTK治疗泰格森浅表性点状角膜病变1例。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000024359.29208.59
Michael H Goldstein, Jonathan A Feistmann, M Tariq Bhatti

Purpose: This article reports a case in which Thygeson's superficial punctate keratopathy was treated with photorefractive keratectomy (PRK) combined with phototherapeutic keratectomy (PTK).

Methods: A 20-year-old white woman in good health who had a 2-year history of Thygeson's superficial punctate keratopathy in both eyes was evaluated for refractive surgery to treat myopia. The patient had experienced multiple recurrences of the Thygeson's during the preceding 2-year period. Previous treatment had consisted of topical steroids with good response to therapy but recurrences once the topical therapy was stopped. After discussing different options, the patient underwent uncomplicated PRK-PTK for treatment of her myopia, and her postoperative course was uneventful.

Results: Eight months after undergoing PRK-PTK, the patient has excellent uncorrected visual acuity (20/20 in both eyes) and has experienced no recurrences of Thygeson's superficial punctate keratopathy.

Conclusions: Successful treatment of Thygeson's superficial punctate keratopathy in a patient with a low myopia may be achieved with the use of combined PRK-PTK procedures.

目的:本文报告一例泰格森浅表点状角膜病变采用光屈光性角膜切除术(PRK)联合光疗性角膜切除术(PTK)治疗。方法:对一名20岁、身体健康、双眼有2年蒂格森浅表面性点状角膜病变病史的白人女性进行屈光手术治疗。在过去的2年里,患者经历了多次复发。先前的治疗包括局部类固醇,治疗反应良好,但一旦局部治疗停止复发。在讨论了不同的选择后,患者接受了简单的PRK-PTK治疗她的近视,她的术后过程平淡无奇。结果:患者行PRK-PTK术后8个月,未矫正视力极佳(双眼20/20),无Thygeson浅表性点状角膜病变复发。结论:采用PRK-PTK联合手术可成功治疗低近视患者的泰格森浅表点状角膜病变。
{"title":"PRK-pTK as a treatment for a patient with Thygeson's superficial punctate keratopathy.","authors":"Michael H Goldstein,&nbsp;Jonathan A Feistmann,&nbsp;M Tariq Bhatti","doi":"10.1097/01.ICL.0000024359.29208.59","DOIUrl":"https://doi.org/10.1097/01.ICL.0000024359.29208.59","url":null,"abstract":"<p><strong>Purpose: </strong>This article reports a case in which Thygeson's superficial punctate keratopathy was treated with photorefractive keratectomy (PRK) combined with phototherapeutic keratectomy (PTK).</p><p><strong>Methods: </strong>A 20-year-old white woman in good health who had a 2-year history of Thygeson's superficial punctate keratopathy in both eyes was evaluated for refractive surgery to treat myopia. The patient had experienced multiple recurrences of the Thygeson's during the preceding 2-year period. Previous treatment had consisted of topical steroids with good response to therapy but recurrences once the topical therapy was stopped. After discussing different options, the patient underwent uncomplicated PRK-PTK for treatment of her myopia, and her postoperative course was uneventful.</p><p><strong>Results: </strong>Eight months after undergoing PRK-PTK, the patient has excellent uncorrected visual acuity (20/20 in both eyes) and has experienced no recurrences of Thygeson's superficial punctate keratopathy.</p><p><strong>Conclusions: </strong>Successful treatment of Thygeson's superficial punctate keratopathy in a patient with a low myopia may be achieved with the use of combined PRK-PTK procedures.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"172-3"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077666","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Comparison of tear-film osmolarity in different types of contact lenses. 不同类型隐形眼镜的泪膜渗透压比较。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000024117.46518.A4
Güzin Iskeleli, Yunus Karakoç, Ozlem Aydin, Hüseyin Yetik, Haşim Uslu, Melda Kizilkaya

Purpose: To investigate the tear-film osmolarity of contact lens wearers for different types of contact lenses.

Methods: Fifty six eyes of 56 cases were evaluated in four different groups according to the type of contact lens worn, with 14 eyes in each group. Groups 1 and 2 consisted of subjects who wore frequent-replacement daily wear soft contact lenses; group 1 lenses had 55% water content, and lenses in group 2 had 38% water content. Groups 3 and 4 consisted of subjects who wore rigid gas-permeable contact lenses, with a Dk value of 90 in group 3 and a Dk value of 52 in group 4. Tear-film osmolarity values in milliosmole (mosm) units were determined by auto-osmometer (Orstat 6030, Daiichi Kagacu, Kyoto, Japan) before and after contact lens wear for each group, and the results were compared statistically by ANOVA test.

Results: Before the period of contact lens wear, the tear-film osmolarity values of group 1, 2, 3, and 4 were 283.61+/-12.83 mosm, 285.23+/-8.94 mosm, 285.57+/-11.39 mosm, and 280.15+/-12.07 mosm, respectively. After the period of contact lens wear, these values were measured at 312.15+/-16.03 mosm in group 1, 316.54+/-12.14 mosm in group 2, 313.14+/-9.66 mosm in group 3, and 316.38+/-11.60 mosm in group 4. Although the difference between the values before and after the period of contact lens wear was statistically significant for each group (F=291.45; P=0.0005), there was no statistically significant difference among the groups.

Conclusions: When a contact lens is placed in the eye, the lens alters the normal structure of the tear film and affects its rate of evaporation; therefore tear-film osmolarity may increase. In our study, all contact lenses produced a similar effect on tear-film osmolarity.

目的:探讨不同类型隐形眼镜佩戴者的泪膜渗透率。方法:56例患者56只眼按配戴隐形眼镜类型分为4组,每组14只眼。第1组和第2组为佩戴每日频繁更换的软性隐形眼镜的受试者;1组晶状体含水量为55%,2组晶状体含水量为38%。第3组和第4组佩戴硬性透气性隐形眼镜,第3组Dk值为90,第4组Dk值为52。采用自动渗透仪(Orstat 6030, Daiichi Kagacu, Kyoto, Japan)测定各组佩戴隐形眼镜前后的泪膜渗透压值,以百万摩尔(mosm)为单位,并采用方差分析(ANOVA)对结果进行统计学比较。结果:佩戴隐形眼镜前,1、2、3、4组的泪膜渗透压值分别为283.61+/-12.83 mosm、285.23+/-8.94 mosm、285.57+/-11.39 mosm、280.15+/-12.07 mosm。佩戴隐形眼镜一段时间后,分别测量1组312.15+/-16.03 mosm、2组316.54+/-12.14 mosm、3组313.14+/-9.66 mosm、4组316.38+/-11.60 mosm。虽然各组佩戴隐形眼镜前后的数值差异有统计学意义(F=291.45;P=0.0005),组间差异无统计学意义。结论:当佩戴隐形眼镜时,晶状体改变泪膜的正常结构,影响泪膜的蒸发速度;因此,泪膜渗透压可能增加。在我们的研究中,所有的隐形眼镜对泪膜渗透性产生了相似的影响。
{"title":"Comparison of tear-film osmolarity in different types of contact lenses.","authors":"Güzin Iskeleli,&nbsp;Yunus Karakoç,&nbsp;Ozlem Aydin,&nbsp;Hüseyin Yetik,&nbsp;Haşim Uslu,&nbsp;Melda Kizilkaya","doi":"10.1097/01.ICL.0000024117.46518.A4","DOIUrl":"https://doi.org/10.1097/01.ICL.0000024117.46518.A4","url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the tear-film osmolarity of contact lens wearers for different types of contact lenses.</p><p><strong>Methods: </strong>Fifty six eyes of 56 cases were evaluated in four different groups according to the type of contact lens worn, with 14 eyes in each group. Groups 1 and 2 consisted of subjects who wore frequent-replacement daily wear soft contact lenses; group 1 lenses had 55% water content, and lenses in group 2 had 38% water content. Groups 3 and 4 consisted of subjects who wore rigid gas-permeable contact lenses, with a Dk value of 90 in group 3 and a Dk value of 52 in group 4. Tear-film osmolarity values in milliosmole (mosm) units were determined by auto-osmometer (Orstat 6030, Daiichi Kagacu, Kyoto, Japan) before and after contact lens wear for each group, and the results were compared statistically by ANOVA test.</p><p><strong>Results: </strong>Before the period of contact lens wear, the tear-film osmolarity values of group 1, 2, 3, and 4 were 283.61+/-12.83 mosm, 285.23+/-8.94 mosm, 285.57+/-11.39 mosm, and 280.15+/-12.07 mosm, respectively. After the period of contact lens wear, these values were measured at 312.15+/-16.03 mosm in group 1, 316.54+/-12.14 mosm in group 2, 313.14+/-9.66 mosm in group 3, and 316.38+/-11.60 mosm in group 4. Although the difference between the values before and after the period of contact lens wear was statistically significant for each group (F=291.45; P=0.0005), there was no statistically significant difference among the groups.</p><p><strong>Conclusions: </strong>When a contact lens is placed in the eye, the lens alters the normal structure of the tear film and affects its rate of evaporation; therefore tear-film osmolarity may increase. In our study, all contact lenses produced a similar effect on tear-film osmolarity.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"174-6"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 69
Spherical indentations of human and rabbit corneal epithelium following extended contact lens wear. 长时间佩戴隐形眼镜后人类和兔子角膜上皮的球形凹痕。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000033621.46837.21
Patrick M Ladage, W Matthew Petroll, James V Jester, Stephen Fisher, Jan P G Bergmanson, H Dwight Cavanagh

Purpose: Mucin balls appear to cause spherical indentations in the corneal epithelium during silicone hydrogel extended contact lens wear. The purpose of this report is to describe and quantify these spherical indentations, as examined in the human cornea by in vivo confocal microscopy and by in vitro immunocytochemistry in the rabbit cornea.

Methods: Confocal images of full-thickness corneal epithelium were taken from three human patients participating in a 1-year extended contact lens-wear trial. Diameter and depth of the indentations were determined and measured. Two rabbit corneas showing identical indentations were stained with propidium iodide (nuclear stain) and Ki-67 (proliferation marker) and were examined using a laser scanning confocal microscope.

Results: The diameter of the spherical indentations is largest on the epithelial surface, ranging from 33.9 to 78.8 microm. Indentations form spherical sections whose depth variably extends into the corneal epithelium, reaching as far as the basal lamina. The rabbit model showed no epithelial nuclei within the indentation. Furthermore, stromal cells localized immediately beneath the indentations were positive for Ki-67 (proliferation).

Discussion: Spherical indentations of the corneal epithelium induced by mucin balls appear to be gaps or holes that can extend deep into the corneal epithelium. Indentations may potentially open a pathway for infectious microorganisms to penetrate the cornea. Surprisingly, stromal cells immediately beneath the holes were stimulated to proliferate, and there seemed to be an increase in localized cell density.

目的:粘蛋白球出现在硅水凝胶延长隐形眼镜佩戴期间引起角膜上皮的球形凹痕。本报告的目的是描述和量化这些球形凹痕,通过体内共聚焦显微镜和兔角膜的体外免疫细胞化学检查。方法:从参加为期1年的延长隐形眼镜佩戴试验的3名人类患者身上采集全层角膜上皮共聚焦图像。确定并测量了压痕的直径和深度。用碘化丙啶(核染色)和Ki-67(增殖标记物)对2只兔角膜进行染色,并用激光扫描共聚焦显微镜观察。结果:上皮表面球形压痕直径最大,为33.9 ~ 78.8 μ m;凹痕形成球形部分,其深度可变化地延伸到角膜上皮,最远可达基底层。兔模型凹痕内未见上皮细胞核。此外,紧靠压痕下方的基质细胞Ki-67(增殖)呈阳性。讨论:粘蛋白球诱导的角膜上皮球形压痕表现为可深入角膜上皮的间隙或孔洞。凹痕可能为感染性微生物渗透角膜开辟了一条潜在的途径。令人惊讶的是,孔洞下面的基质细胞被刺激增殖,并且局部细胞密度似乎有所增加。
{"title":"Spherical indentations of human and rabbit corneal epithelium following extended contact lens wear.","authors":"Patrick M Ladage,&nbsp;W Matthew Petroll,&nbsp;James V Jester,&nbsp;Stephen Fisher,&nbsp;Jan P G Bergmanson,&nbsp;H Dwight Cavanagh","doi":"10.1097/01.ICL.0000033621.46837.21","DOIUrl":"https://doi.org/10.1097/01.ICL.0000033621.46837.21","url":null,"abstract":"<p><strong>Purpose: </strong>Mucin balls appear to cause spherical indentations in the corneal epithelium during silicone hydrogel extended contact lens wear. The purpose of this report is to describe and quantify these spherical indentations, as examined in the human cornea by in vivo confocal microscopy and by in vitro immunocytochemistry in the rabbit cornea.</p><p><strong>Methods: </strong>Confocal images of full-thickness corneal epithelium were taken from three human patients participating in a 1-year extended contact lens-wear trial. Diameter and depth of the indentations were determined and measured. Two rabbit corneas showing identical indentations were stained with propidium iodide (nuclear stain) and Ki-67 (proliferation marker) and were examined using a laser scanning confocal microscope.</p><p><strong>Results: </strong>The diameter of the spherical indentations is largest on the epithelial surface, ranging from 33.9 to 78.8 microm. Indentations form spherical sections whose depth variably extends into the corneal epithelium, reaching as far as the basal lamina. The rabbit model showed no epithelial nuclei within the indentation. Furthermore, stromal cells localized immediately beneath the indentations were positive for Ki-67 (proliferation).</p><p><strong>Discussion: </strong>Spherical indentations of the corneal epithelium induced by mucin balls appear to be gaps or holes that can extend deep into the corneal epithelium. Indentations may potentially open a pathway for infectious microorganisms to penetrate the cornea. Surprisingly, stromal cells immediately beneath the holes were stimulated to proliferate, and there seemed to be an increase in localized cell density.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"177-80"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077668","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 29
Initial selection of soft contact lenses based on corneal characteristics. 根据角膜特征初步选择软性隐形眼镜。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000029342.53776.B1
William A Douthwaite

Purpose: To determine apical radius, surface asphericity, and horizontal visible iris diameters (HVID) in normal subjects and to find out which has the greatest influence on the corneal sagittal depth.

Methods: Videokeratoscopic data were analyzed to determine the apical radius and the p-value of the near horizontal principal meridian for 73 right and 77 left eyes. The HVID also were measured.

Results: Scatterplots of sagittal depth versus apical radius, p-value, and HVID indicated the strongest association between the sagittal depth and the HVID.

Conclusions: Normal variations in corneal asphericity have the least influence whereas normal variations in HVID have the greatest influence in changing the corneal sagittal depth. The most appropriate measurement to take to select the optimum soft contact lens specification may be the HVID.

目的:测定正常人的根尖半径、表面非球度和水平可见虹膜直径(HVID),找出对角膜矢状面深度影响最大的因素。方法:对73例右眼和77例左眼的视像透视资料进行分析,确定近水平主经络的根尖半径和p值。HVID也被测量。结果:矢状面深度与根尖半径、p值和HVID的散点图显示矢状面深度与HVID之间的相关性最强。结论:角膜非球状度的正常变化对角膜矢状深度的影响最小,而HVID的正常变化对角膜矢状深度的影响最大。选择最佳软性隐形眼镜规格最合适的测量方法可能是HVID。
{"title":"Initial selection of soft contact lenses based on corneal characteristics.","authors":"William A Douthwaite","doi":"10.1097/01.ICL.0000029342.53776.B1","DOIUrl":"https://doi.org/10.1097/01.ICL.0000029342.53776.B1","url":null,"abstract":"<p><strong>Purpose: </strong>To determine apical radius, surface asphericity, and horizontal visible iris diameters (HVID) in normal subjects and to find out which has the greatest influence on the corneal sagittal depth.</p><p><strong>Methods: </strong>Videokeratoscopic data were analyzed to determine the apical radius and the p-value of the near horizontal principal meridian for 73 right and 77 left eyes. The HVID also were measured.</p><p><strong>Results: </strong>Scatterplots of sagittal depth versus apical radius, p-value, and HVID indicated the strongest association between the sagittal depth and the HVID.</p><p><strong>Conclusions: </strong>Normal variations in corneal asphericity have the least influence whereas normal variations in HVID have the greatest influence in changing the corneal sagittal depth. The most appropriate measurement to take to select the optimum soft contact lens specification may be the HVID.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"202-5"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077619","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
A comparison of two pachymetric systems: slit-scanning and ultrasonic. 裂隙扫描和超声两种测厚系统的比较。
Pub Date : 2002-10-01 DOI: 10.1097/01.ICL.0000034556.15901.CC
Maria Jesus Giraldez Fernandez, Alberto Diaz Rey, Alejandro Cerviño, Eva Yebra-Pimentel

Purpose: This article compares measurements of corneal thickness obtained with the Orbscan Topography System with those obtained with the ultrasonic pachymeter, when used to measure central-comeal thickness in normal subjects.

Methods: Slit-scan topography (Orbscan II system, version 3.0, Bausch & Lomb, Rochester, NY) and ultrasonic pachymetry (Ophthasonic A-Scan/ Pachometer III, Accutome, Malvern, PA) were used to measure central-corneal thickness in 92 right corneas of 92 healthy adult subjects. A correlation analysis was used to evaluate the relationship between both instruments. Measurements were also compared by plotting the difference between the methods against the average. The hypothesis of zero bias was examined by a paired t-test. The 95% limits of agreement also were calculated.

Results: The mean corneal thickness was 559.9 microm +/-3.73 SEM with the Orbscan system and 551.2 microm +/- 4.57 SEM with the ultrasonic pachymeter, values that were significantly different (paired t-test, P = 0.000). The coefficient of determination was 0.860 (y = -65.78 + 1.135 x; P = 0.000). The mean difference between the measurements from both devices was found to be significantly different from zero (mean: 8.74 microm; paired t-test; P = 0.000), with Orbscan being slightly higher than the Ophthasonic A-Scan.

Conclusions: The Orbscan system measurements of central corneal thickness were greater than ultrasonic pachymeter measurements, a difference that was statistically significantly.

目的:本文比较了用Orbscan地形测量系统测量角膜厚度与超声测厚仪测量正常受试者角膜中心厚度的结果。方法:采用裂隙扫描形貌仪(Orbscan II系统,3.0版,Bausch & Lomb, Rochester, NY)和超声测厚仪(ophth超声A-Scan/ Pachometer III, Accutome, Malvern, PA)测量92名健康成人的92个右角膜中央角膜厚度。使用相关分析来评估两种仪器之间的关系。还通过绘制方法与平均值之间的差异来比较测量结果。采用配对t检验检验零偏差假设。并计算了95%的一致性限度。结果:Orbscan系统测得的角膜平均厚度为559.9 μ m +/-3.73 SEM,超声测厚仪测得的角膜平均厚度为551.2 μ m +/- 4.57 SEM,差异有统计学意义(配对t检验,P = 0.000)。决定系数为0.860 (y = -65.78 + 1.135 x;P = 0.000)。两种装置测量值的平均差被发现明显不同于零(平均值:8.74微米;配对t检验;P = 0.000), Orbscan略高于超声A-Scan。结论:Orbscan系统测得的角膜中央厚度大于超声测得的角膜厚度,差异有统计学意义。
{"title":"A comparison of two pachymetric systems: slit-scanning and ultrasonic.","authors":"Maria Jesus Giraldez Fernandez,&nbsp;Alberto Diaz Rey,&nbsp;Alejandro Cerviño,&nbsp;Eva Yebra-Pimentel","doi":"10.1097/01.ICL.0000034556.15901.CC","DOIUrl":"https://doi.org/10.1097/01.ICL.0000034556.15901.CC","url":null,"abstract":"<p><strong>Purpose: </strong>This article compares measurements of corneal thickness obtained with the Orbscan Topography System with those obtained with the ultrasonic pachymeter, when used to measure central-comeal thickness in normal subjects.</p><p><strong>Methods: </strong>Slit-scan topography (Orbscan II system, version 3.0, Bausch & Lomb, Rochester, NY) and ultrasonic pachymetry (Ophthasonic A-Scan/ Pachometer III, Accutome, Malvern, PA) were used to measure central-corneal thickness in 92 right corneas of 92 healthy adult subjects. A correlation analysis was used to evaluate the relationship between both instruments. Measurements were also compared by plotting the difference between the methods against the average. The hypothesis of zero bias was examined by a paired t-test. The 95% limits of agreement also were calculated.</p><p><strong>Results: </strong>The mean corneal thickness was 559.9 microm +/-3.73 SEM with the Orbscan system and 551.2 microm +/- 4.57 SEM with the ultrasonic pachymeter, values that were significantly different (paired t-test, P = 0.000). The coefficient of determination was 0.860 (y = -65.78 + 1.135 x; P = 0.000). The mean difference between the measurements from both devices was found to be significantly different from zero (mean: 8.74 microm; paired t-test; P = 0.000), with Orbscan being slightly higher than the Ophthasonic A-Scan.</p><p><strong>Conclusions: </strong>The Orbscan system measurements of central corneal thickness were greater than ultrasonic pachymeter measurements, a difference that was statistically significantly.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"28 4","pages":"221-3"},"PeriodicalIF":0.0,"publicationDate":"2002-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"22077623","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 48
期刊
The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1