Elektromagnetische Bioinformation im Frequenzbereich von 100 Hz bis 100 kHz?

Q Medicine Forschende Komplementarmedizin Pub Date : 1998-01-01 DOI:10.1159/000021111
Klima, Lipp, Lahrmann, Bachtik
{"title":"Elektromagnetische Bioinformation im Frequenzbereich von 100 Hz bis 100 kHz?","authors":"Klima,&nbsp;Lipp,&nbsp;Lahrmann,&nbsp;Bachtik","doi":"10.1159/000021111","DOIUrl":null,"url":null,"abstract":"<p><p>Electromagnetic Bioinformation in the Frequency Region between 100 Hz and 100 kHz? A highly sensitive measurement amplifier (BIT device) was constructed in order to detect possible electromagnetic biosignals in the frequency region between 100 Hz and 100 kHz. Even when working with the highest amplification mode of the BIT device, no endogenous electromagnetic biosignals could be detected on the test persons, but only well-known EMG signals. If the BIT device worked in a feedback mode, electromagnetic oscillations beween 1.7 and 2.9 kHz could be generated and oscilloscopically detected; these oscillations are caused by the oscillator system 'BIT - man', depending on the impedance of the human body. Biological effects of the impedance-depending oscillations were investigated in a simple randomized double-blind study. Three anamnestically healthy persons were treated 20 times with their specific oscillations. The physiological effects of this treatment were measured by pulse plethysmography. Nonlinear analysis of the time series indicated significant changes in pulse dynamics of one person. Linear analysis of heart rate variability showed no statistical significance. Our device was only designed for the project described below. It is, therefore, evident that the research results presented in this paper cannot be applied to any of the therapy devices at present on the market.</p>","PeriodicalId":54318,"journal":{"name":"Forschende Komplementarmedizin","volume":"5 5","pages":"230-235"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1159/000021111","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Forschende Komplementarmedizin","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000021111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 3

Abstract

Electromagnetic Bioinformation in the Frequency Region between 100 Hz and 100 kHz? A highly sensitive measurement amplifier (BIT device) was constructed in order to detect possible electromagnetic biosignals in the frequency region between 100 Hz and 100 kHz. Even when working with the highest amplification mode of the BIT device, no endogenous electromagnetic biosignals could be detected on the test persons, but only well-known EMG signals. If the BIT device worked in a feedback mode, electromagnetic oscillations beween 1.7 and 2.9 kHz could be generated and oscilloscopically detected; these oscillations are caused by the oscillator system 'BIT - man', depending on the impedance of the human body. Biological effects of the impedance-depending oscillations were investigated in a simple randomized double-blind study. Three anamnestically healthy persons were treated 20 times with their specific oscillations. The physiological effects of this treatment were measured by pulse plethysmography. Nonlinear analysis of the time series indicated significant changes in pulse dynamics of one person. Linear analysis of heart rate variability showed no statistical significance. Our device was only designed for the project described below. It is, therefore, evident that the research results presented in this paper cannot be applied to any of the therapy devices at present on the market.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
从100赫兹到100赫兹的高频率电磁生物信息?
100赫兹和100千赫之间频率区域的电磁生物信息?为了检测100hz ~ 100khz范围内可能存在的电磁生物信号,设计了高灵敏度测量放大器(BIT)。即使在BIT设备的最高放大模式下工作,在被试身上也无法检测到内源性的电磁生物信号,只能检测到已知的肌电信号。如果BIT器件工作在反馈模式下,可以产生1.7 ~ 2.9 kHz的电磁振荡,并通过示波器检测到;这些振荡是由振荡器系统“BIT - man”引起的,取决于人体的阻抗。在一项简单的随机双盲研究中,研究了阻抗相关振荡的生物学效应。对3名健全人进行20次特异性振荡治疗。这种治疗的生理效果通过脉搏体积描记术测量。时间序列的非线性分析表明,一个人的脉搏动力学发生了显著变化。心率变异性线性分析无统计学意义。我们的设备仅为下面描述的项目设计。因此,很明显,本文的研究结果不能应用于目前市场上的任何治疗设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
期刊最新文献
Unusual claims, normative process: on the use and stringency of the scientific method. Prospective controlled cohort studies on long-term therapy of cervical cancer patients with a mistletoe preparation (Iscador). Supportive evidence for the anticancerous potential of alternative medicine against hepatocarcinogenesis in mice. [Repeated cold water stimulations (hydrotherapy according to Kneipp) in patients with COPD]. [Evaluation of use of complementary and alternative medicine by schizophrenic patients].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1