Collaborative study for the validation of serological methods for potency testing of diphtheria toxoid vaccines - extended study: correlation of serology with in vivo toxin neutralisation.
{"title":"Collaborative study for the validation of serological methods for potency testing of diphtheria toxoid vaccines - extended study: correlation of serology with in vivo toxin neutralisation.","authors":"D Sesardic, R Winsnes, P Rigsby, M-E Behr-Gross","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Phase I of BSP034 collaborative study was extended in two laboratories to include correlation of serology with in vivo toxin neutralisation test (TNT) using 2 separate sets of 20 serum pools, produced in-house. The study investigated the extent to which the in vitro methods for diphtheria antibodies, Vero cell assay and diphtheria enzyme-linked immunosorbent assay for diphtheria antitoxin (D-ELISA), can detect neutralising antibodies by comparison with TNT in guinea pigs. The study was also performed to compare the antibody neutralising potency obtained in relation to guinea pig (GP) or equine (DI) antitoxin standard. In addition, the study provided an opportunity to compare ELISA for tetanus antitoxin (T-ELISA) and TNT assay for detection of anti-tetanus antibodies, from the same set of serum pools. The data obtained show that antitoxin potency obtained by Vero cell assay, D-ELISA and T-ELISA using the same GP standard, highly correlated with neutralising potency as determined in respective TNT assays. Vero cell assay with DI provided estimates that also correlated with neutralising potency, but were of significantly lower titre. Since reference to DI standard is widely used in serodiagnosis, as well as in clinical studies where diphtheria antitoxin titres obtained in the Vero cell method are taken as surrogate markers for vaccine efficacy, it should be investigated if a similar difference is also observed for human serology.</p>","PeriodicalId":86996,"journal":{"name":"Pharmeuropa bio","volume":"2003 2","pages":"69-76"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Phase I of BSP034 collaborative study was extended in two laboratories to include correlation of serology with in vivo toxin neutralisation test (TNT) using 2 separate sets of 20 serum pools, produced in-house. The study investigated the extent to which the in vitro methods for diphtheria antibodies, Vero cell assay and diphtheria enzyme-linked immunosorbent assay for diphtheria antitoxin (D-ELISA), can detect neutralising antibodies by comparison with TNT in guinea pigs. The study was also performed to compare the antibody neutralising potency obtained in relation to guinea pig (GP) or equine (DI) antitoxin standard. In addition, the study provided an opportunity to compare ELISA for tetanus antitoxin (T-ELISA) and TNT assay for detection of anti-tetanus antibodies, from the same set of serum pools. The data obtained show that antitoxin potency obtained by Vero cell assay, D-ELISA and T-ELISA using the same GP standard, highly correlated with neutralising potency as determined in respective TNT assays. Vero cell assay with DI provided estimates that also correlated with neutralising potency, but were of significantly lower titre. Since reference to DI standard is widely used in serodiagnosis, as well as in clinical studies where diphtheria antitoxin titres obtained in the Vero cell method are taken as surrogate markers for vaccine efficacy, it should be investigated if a similar difference is also observed for human serology.