Collaborative study for the establishment of replacement batches for human coagulation factor IX concentrate reference standards.

Pharmeuropa bio Pub Date : 2008-12-01
E Gray, W Pickering, J Hockley, P Rigsby, M Weinstein, E Terao, K-H Buchheit
{"title":"Collaborative study for the establishment of replacement batches for human coagulation factor IX concentrate reference standards.","authors":"E Gray,&nbsp;W Pickering,&nbsp;J Hockley,&nbsp;P Rigsby,&nbsp;M Weinstein,&nbsp;E Terao,&nbsp;K-H Buchheit","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) batch 1, the World Health Organisation (WHO) 3rd International Standard, Human (IS, 96/854) and the FDA Standard for human blood coagulation Factor IX concentrate have been available since 1996, following their establishment by a common collaborative study. Due to dwindling stocks of all three standards, a new WHO-EDQM-FDA tri-partite collaborative study was launched to establish replacement batches. Thirty laboratories from fourteen countries took part in the collaborative study to assign potency values to candidate preparations. Three candidates, one of recombinant and two of human plasma-derived origins, were assayed against the 3rd IS for Blood Coagulation Factor IX, Concentrate, Human (96/854). The 3rd IS for Blood Coagulation Factors II, VII, IX and X, Plasma, Human (99/826) was also included to evaluate the relationship between the factor IX plasma and concentrate unitage. Thirty-two sets of clotting assay results and two sets of chromogenic assay data were analysed. There was a significant difference in potency estimates by these two methods for the recombinant candidate (sample B) and the plasma IS (sample P). Similar potency values were obtained for the plasma derived products (monoclonal antibody- and chromatography-purified factor IX, samples C and D) by clotting and chromogenic assays. For the clotting assays, intra-laboratory variability (GCV) was found to range from 0.5 - 21.7%, with the GCV for the majority of laboratories being less than 10%. Good inter-laboratory agreement, with the majority of the GCV being less than 10% (GCV range = 4.7 - 10.6 %) was also obtained. The mean potency values estimated by the clotting assay using plasma as pre-diluent (as directed by the Ph. Eur. general chapter method) did not differ from values obtained using buffer. Taking into account the preliminary stability data, the intra- and inter-laboratory variability, and the differences between the clotting and chromogenic assay results, sample C (07/182) was established as the Human coagulation factor IX concentrate BRP batch 2, with a potency value of 7.9 IU/ampoule assigned with clotting assay results. As an outcome of this tri-partite collaborative study, the same sample C (07/182) has also been adopted as the 4th International Standard for Blood Coagulation Factor IX, Concentrate, Human by the Expert Committee on Biological Standardisation (ECBS) of the World Health Organisation (WHO), and as the replacement batch for the reference standard for Human coagulation factor IX concentrate by the FDA.</p>","PeriodicalId":86996,"journal":{"name":"Pharmeuropa bio","volume":"2008 1","pages":"19-30"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The European Pharmacopoeia (Ph. Eur.) Biological Reference Preparation (BRP) batch 1, the World Health Organisation (WHO) 3rd International Standard, Human (IS, 96/854) and the FDA Standard for human blood coagulation Factor IX concentrate have been available since 1996, following their establishment by a common collaborative study. Due to dwindling stocks of all three standards, a new WHO-EDQM-FDA tri-partite collaborative study was launched to establish replacement batches. Thirty laboratories from fourteen countries took part in the collaborative study to assign potency values to candidate preparations. Three candidates, one of recombinant and two of human plasma-derived origins, were assayed against the 3rd IS for Blood Coagulation Factor IX, Concentrate, Human (96/854). The 3rd IS for Blood Coagulation Factors II, VII, IX and X, Plasma, Human (99/826) was also included to evaluate the relationship between the factor IX plasma and concentrate unitage. Thirty-two sets of clotting assay results and two sets of chromogenic assay data were analysed. There was a significant difference in potency estimates by these two methods for the recombinant candidate (sample B) and the plasma IS (sample P). Similar potency values were obtained for the plasma derived products (monoclonal antibody- and chromatography-purified factor IX, samples C and D) by clotting and chromogenic assays. For the clotting assays, intra-laboratory variability (GCV) was found to range from 0.5 - 21.7%, with the GCV for the majority of laboratories being less than 10%. Good inter-laboratory agreement, with the majority of the GCV being less than 10% (GCV range = 4.7 - 10.6 %) was also obtained. The mean potency values estimated by the clotting assay using plasma as pre-diluent (as directed by the Ph. Eur. general chapter method) did not differ from values obtained using buffer. Taking into account the preliminary stability data, the intra- and inter-laboratory variability, and the differences between the clotting and chromogenic assay results, sample C (07/182) was established as the Human coagulation factor IX concentrate BRP batch 2, with a potency value of 7.9 IU/ampoule assigned with clotting assay results. As an outcome of this tri-partite collaborative study, the same sample C (07/182) has also been adopted as the 4th International Standard for Blood Coagulation Factor IX, Concentrate, Human by the Expert Committee on Biological Standardisation (ECBS) of the World Health Organisation (WHO), and as the replacement batch for the reference standard for Human coagulation factor IX concentrate by the FDA.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
人凝血因子IX浓缩液参考标准替代批次建立的协同研究。
欧洲药典(Ph. Eur.)生物参考制剂(BRP)第1批,世界卫生组织(WHO)第三国际标准,人类(IS, 96/854)和FDA人类凝血因子IX浓缩物标准,通过共同合作研究建立,自1996年以来一直可用。由于所有三种标准的库存都在减少,因此启动了一项新的WHO-EDQM-FDA三方合作研究,以确定替代批次。来自14个国家的30个实验室参加了为候选制剂指定效价值的合作研究。3个候选物,1个重组和2个人血浆源性来源,进行了血液凝固因子IX,浓缩物,人(96/854)的第3 IS检测。还纳入了人血浆凝血因子II、VII、IX和X(99/826)的第3项IS,以评估血浆凝血因子IX与浓缩单位的关系。分析了32组凝血试验结果和2组显色试验数据。这两种方法对重组候选物(样品B)和血浆IS(样品P)的效价估计有显著差异。通过凝血和显色测定,血浆衍生产物(单克隆抗体和色谱纯化因子IX,样品C和D)的效价值相似。对于凝血测定,实验室内变异(GCV)的范围为0.5 - 21.7%,大多数实验室的GCV小于10%。实验室间一致性良好,大多数GCV小于10% (GCV范围= 4.7 - 10.6%)。使用血浆作为预稀释液的凝血测定所估计的平均效价值(按照欧洲药理学博士的指示)。通章方法)与使用缓冲区获得的值没有区别。考虑到初步稳定性数据、实验室内和实验室间的可变性以及凝血和显色分析结果之间的差异,样品C(07/182)被确定为人凝血因子IX浓缩物BRP第2批,其效价为7.9 IU/安瓿。作为三方合作研究的结果,同一样品C(07/182)也被世界卫生组织(WHO)生物标准化专家委员会(ECBS)采纳为第4个人凝血因子IX浓缩物国际标准,并被FDA作为人凝血因子IX浓缩物参考标准的替代批次。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Establishment of replacement batches for prekallikrein activator in albumin biological reference preparation. Evaluation of two serological methods for potency testing of whole cell pertussis vaccines. Collaborative study for the establishment of replacement batches for human coagulation factor IX concentrate reference standards. Determination of Oversulphated Chondroitin Sulphate and Dermatan Sulphate in unfractionated heparin by (1)H-NMR - Collaborative study for quantification and analytical determination of LoD. Biological activity of EDQM CRS for Interferon alfa-2a and Interferon alfa-2b - assessment in two in vitro bioassays.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1