Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study.
M C Müller, P Belei, M De La Fuente, M Strake, O Weber, C Burger, K Radermacher, D C Wirtz
{"title":"Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study.","authors":"M C Müller, P Belei, M De La Fuente, M Strake, O Weber, C Burger, K Radermacher, D C Wirtz","doi":"10.3109/10929088.2010.542694","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate placement of cannulated screws is essential to ensure fixation of medial femoral neck fractures. The conventional technique may require multiple guide wire passes, and relies heavily on fluoroscopy. A computer-assisted planning and navigation system based on 2D fluoroscopy for guide wire placement in the femoral neck has been developed to improve screw placement. The planning process was supported by a tool that enables a virtual radiation-free preview of X-ray images. This is called \"zero-dose C-arm navigation\". For the evaluation of the system, six formalin-fixed cadaveric full-body specimens (12 femurs) were used. The evaluation demonstrated the feasibility of fluoroscopically navigated guide wire and implant placement. Use of the novel system resulted in a significant reduction in the number of fluoroscopic images and drilling attempts while achieving optimized accuracy by attaining better screw parallelism and enlarged neck-width coverage. Operation time was significantly longer in the navigation assisted group. The system has yielded promising initial results; however, additional studies using fractured bone models and with extension of the navigation process to track two bone fragments must be performed before integration of this navigation system into the clinical workflow is possible, and these studies should focus on reducing the operation time.</p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"16 1","pages":"22-31"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2010.542694","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2010.542694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 11
Abstract
Accurate placement of cannulated screws is essential to ensure fixation of medial femoral neck fractures. The conventional technique may require multiple guide wire passes, and relies heavily on fluoroscopy. A computer-assisted planning and navigation system based on 2D fluoroscopy for guide wire placement in the femoral neck has been developed to improve screw placement. The planning process was supported by a tool that enables a virtual radiation-free preview of X-ray images. This is called "zero-dose C-arm navigation". For the evaluation of the system, six formalin-fixed cadaveric full-body specimens (12 femurs) were used. The evaluation demonstrated the feasibility of fluoroscopically navigated guide wire and implant placement. Use of the novel system resulted in a significant reduction in the number of fluoroscopic images and drilling attempts while achieving optimized accuracy by attaining better screw parallelism and enlarged neck-width coverage. Operation time was significantly longer in the navigation assisted group. The system has yielded promising initial results; however, additional studies using fractured bone models and with extension of the navigation process to track two bone fragments must be performed before integration of this navigation system into the clinical workflow is possible, and these studies should focus on reducing the operation time.
期刊介绍:
The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.