The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System.

Korean diabetes journal Pub Date : 2010-12-01 Epub Date: 2010-12-31 DOI:10.4093/kdj.2010.34.6.350
Young Ha Baek, Heung Yong Jin, Kyung Ae Lee, Seon Mee Kang, Woong Ji Kim, Min Gul Kim, Ji Hyun Park, Soo Wan Chae, Hong Sun Baek, Tae Sun Park
{"title":"The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System.","authors":"Young Ha Baek,&nbsp;Heung Yong Jin,&nbsp;Kyung Ae Lee,&nbsp;Seon Mee Kang,&nbsp;Woong Ji Kim,&nbsp;Min Gul Kim,&nbsp;Ji Hyun Park,&nbsp;Soo Wan Chae,&nbsp;Hong Sun Baek,&nbsp;Tae Sun Park","doi":"10.4093/kdj.2010.34.6.350","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects.</p><p><strong>Methods: </strong>Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined.</p><p><strong>Results: </strong>CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day.</p><p><strong>Conclusion: </strong>The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean.</p>","PeriodicalId":88924,"journal":{"name":"Korean diabetes journal","volume":"34 6","pages":"350-8"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4093/kdj.2010.34.6.350","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean diabetes journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4093/kdj.2010.34.6.350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2010/12/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Background: Clinical experience with the continuous glucose monitoring systems (CGMS) is limited in Korea. The objective of this study is to evaluate the accuracy of the CGMS and the correlation between interstitial fluid and venous plasma glucose level in Korean healthy male subjects.

Methods: Thirty-two subjects were served with glucose solution contained same amount of test food's carbohydrate and test foods after separate overnight fasts. CGMS was performed over 3 days during hopitalization for each subjects. Venous plasma glucose measurements were carried out during 4 hours (0, 0.25, 0.5, 0.75, 1, 2, 4 hours) just before and after glucose solution and test food load. The performance of the CGMS was evaluated by comparing its readings to those obtained at the same time by the hexokinase method using the auto biochemistry machine (Hitachi 7600-110). Also, correlations between glucose recorded with CGMS and venous plasma glucose value were examined.

Results: CGMS slightly underestimated the glucose value as compared with the venous plasma glucose level (16.3 ± 22.2 mg/dL). Correlation between CGMS and venous plasma glucose values throughout sensor lifetime is 0.73 (regression analysis: slope = 1.08, intercept = 8.38 mg/dL). Sensor sensitivity can deteriorate over time, with correlations between venous blood glucose and CGMS values dropping from 0.77 during 1st day to 0.65 during 2nd and 3rd day.

Conclusion: The accuracy of data provided by CGMS may be less than expected. CGMS sensor sensitivity is decreased with the passage of time. But, from this study, CGMS can be used for glucose variability tendency monitoring conveniently to the Korean.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连续血糖监测系统监测间质液与静脉血浆血糖水平的相关性及准确性。
背景:连续血糖监测系统(CGMS)的临床经验在韩国是有限的。本研究的目的是评估韩国健康男性CGMS的准确性以及间质液和静脉血浆葡萄糖水平的相关性。方法:32名受试者分别禁食过夜后,分别给予含有等量试验食物碳水化合物和试验食物的葡萄糖溶液。在住院期间对每个受试者进行为期3天的CGMS。在葡萄糖溶液和测试食物负荷前后4小时(0、0.25、0.5、0.75、1、2、4小时)进行静脉血浆葡萄糖测量。利用自动生化仪(Hitachi 7600-110)将CGMS的读数与己糖激酶法同时获得的读数进行比较,以评价CGMS的性能。同时,研究了CGMS记录的葡萄糖与静脉血浆葡萄糖值的相关性。结果:CGMS较静脉血浆血糖值(16.3±22.2 mg/dL)有轻微低估。传感器寿命期间CGMS与静脉血浆葡萄糖值的相关性为0.73(回归分析:斜率= 1.08,截距= 8.38 mg/dL)。传感器的灵敏度会随着时间的推移而下降,静脉血血糖与CGMS值的相关性从第1天的0.77下降到第2天和第3天的0.65。结论:CGMS提供的数据准确性可能低于预期。CGMS传感器的灵敏度随时间的推移而降低。但是,从本研究来看,CGMS可以方便地用于韩国人的葡萄糖变异性趋势监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Triple Combination Therapy Using Metformin, Thiazolidinedione, and a GLP-1 Analog or DPP-IV Inhibitor in Patients with Type 2 Diabetes Mellitus. Correlations of glucose levels in interstitial fluid estimated by continuous glucose monitoring systems and venous plasma. The Small Rice Bowl-Based Meal Plan was Effective at Reducing Dietary Energy Intake, Body Weight, and Blood Glucose Levels in Korean Women with Type 2 Diabetes Mellitus. The Correlation and Accuracy of Glucose Levels between Interstitial Fluid and Venous Plasma by Continuous Glucose Monitoring System. A retrospective study on the efficacy of a ten-milligram dosage of atorvastatin for treatment of hypercholesterolemia in type 2 diabetes mellitus patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1