Re-learning curve for conventional total knee arthroplasty following 30 consecutive computer-assisted total knee arthroplasties.

Q Medicine Computer Aided Surgery Pub Date : 2013-01-01 Epub Date: 2013-02-04 DOI:10.3109/10929088.2012.762044
Luke T Nicholson, David Trofa, Eric Smith
{"title":"Re-learning curve for conventional total knee arthroplasty following 30 consecutive computer-assisted total knee arthroplasties.","authors":"Luke T Nicholson,&nbsp;David Trofa,&nbsp;Eric Smith","doi":"10.3109/10929088.2012.762044","DOIUrl":null,"url":null,"abstract":"<p><p>A learning curve for returning to conventional total knee arthroplasty (TKA) after using computer-assisted (CAS) TKA has not yet been established. In this study, the postoperative mechanical axes of the first 30 consecutive CAS TKAs performed by a single surgeon were compared to his subsequent 120 conventionally performed TKAs. A \"re-learning curve\" of 30 conventional TKAs was necessary to attain an average postoperative mechanical axis statistically indistinguishable from the average CAS mechanical axis (1.99°). This is a trend of which surgeons should be aware when converting from CAS TKA to conventional TKA. As a secondary goal, the authors identify the first clinical parameter, preoperative deviation from neutral mechanical axis, that may potentially serve as a guide for the selective use of CAS in TKA. </p>","PeriodicalId":50644,"journal":{"name":"Computer Aided Surgery","volume":"18 3-4","pages":"63-7"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10929088.2012.762044","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Aided Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10929088.2012.762044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/2/4 0:00:00","PubModel":"Epub","JCR":"Q","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4

Abstract

A learning curve for returning to conventional total knee arthroplasty (TKA) after using computer-assisted (CAS) TKA has not yet been established. In this study, the postoperative mechanical axes of the first 30 consecutive CAS TKAs performed by a single surgeon were compared to his subsequent 120 conventionally performed TKAs. A "re-learning curve" of 30 conventional TKAs was necessary to attain an average postoperative mechanical axis statistically indistinguishable from the average CAS mechanical axis (1.99°). This is a trend of which surgeons should be aware when converting from CAS TKA to conventional TKA. As a secondary goal, the authors identify the first clinical parameter, preoperative deviation from neutral mechanical axis, that may potentially serve as a guide for the selective use of CAS in TKA.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连续30例计算机辅助全膝关节置换术后常规全膝关节置换术的再学习曲线。
计算机辅助全膝关节置换术(CAS)后恢复到传统全膝关节置换术(TKA)的学习曲线尚未建立。在本研究中,将同一位外科医生前30例连续CAS tka的术后机械轴与随后的120例常规tka进行比较。30个传统tka的“再学习曲线”是必要的,以获得统计上与平均CAS机械轴(1.99°)无法区分的平均术后机械轴。这是外科医生从CAS TKA转为传统TKA时应注意的趋势。作为次要目标,作者确定了第一个临床参数,术前偏离中性机械轴,这可能作为TKA中选择性使用CAS的指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Computer Aided Surgery
Computer Aided Surgery 医学-外科
CiteScore
0.75
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The scope of Computer Aided Surgery encompasses all fields within surgery, as well as biomedical imaging and instrumentation, and digital technology employed as an adjunct to imaging in diagnosis, therapeutics, and surgery. Topics featured include frameless as well as conventional stereotaxic procedures, surgery guided by ultrasound, image guided focal irradiation, robotic surgery, and other therapeutic interventions that are performed with the use of digital imaging technology.
期刊最新文献
One-step reconstruction with a 3D-printed, biomechanically evaluated custom implant after complex pelvic tumor resection. Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images. Numerical simulation of blood flow and plaque progression in carotid-carotid bypass patient specific case. Towards the clinical integration of an image-guided navigation system for percutaneous liver tumor ablation using freehand 2D ultrasound images. A comparison of two surgical approaches in functional neurosurgery: individualized versus conventional stereotactic frames.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1