Reproducibility of peak power output during a 10-s cycling maximal effort using different sampling rates.

J P Duarte, Manuel J Coelho-E-Silva, V Severino, D Martinho, L Luz, J R Pereira, R Baptista, J Valente-Dos-Santos, A M Machado-Rodrigues, V Vaz, A Cupido-Dos-Santos, J Martín-Hernández, S P Cumming, R M Malina
{"title":"Reproducibility of peak power output during a 10-s cycling maximal effort using different sampling rates.","authors":"J P Duarte,&nbsp;Manuel J Coelho-E-Silva,&nbsp;V Severino,&nbsp;D Martinho,&nbsp;L Luz,&nbsp;J R Pereira,&nbsp;R Baptista,&nbsp;J Valente-Dos-Santos,&nbsp;A M Machado-Rodrigues,&nbsp;V Vaz,&nbsp;A Cupido-Dos-Santos,&nbsp;J Martín-Hernández,&nbsp;S P Cumming,&nbsp;R M Malina","doi":"10.1556/APhysiol.101.2014.009","DOIUrl":null,"url":null,"abstract":"<p><p>The study was aimed to investigate the reproducibility of performance parameters obtained from 10-s maximal cycling effort against different braking forces in young adult athletes. The sample (n = 48) included male athletes aged 18.9-29.9 years (175.5 ± 6.9 cm, 76.2 ± 10.1 kg). The exercise protocol was performed in a cycle-ergometer against a random braking force (4% to 11% of body mass). Intra-individual variation was examined from repeated tests within one week. Descriptive statistics were computed and differences between sessions were tested using paired t-test. The coefficient of correlation between repeated measures, technical error of measurement (TEM), coefficient of variation and ICC were calculated. Agreement between trials was examined using the Bland-Altman procedure. Mean values of peak power were relatively stable when obtained from sampling rates of 50 Hz and ranged between 1068 watt and 1082 watt (t(47) = 1.149, p = 0.256, ES-r = 0.165) or while corresponding to a sampling rate of 1 Hz (t(47) = 0.742, p = 0.462, ES-r = 0.107). Correlations between repeated measures were high (+0.907, 95% CI: +0.839 to +0.947) and TEM about 59.3 watt (%CV = 5.52%; ICC = 0.951, 95% CI: 0.912 to 0.972). The present study suggests that reproducibility of peak power in male adult athletes tended to be acceptable and within individual error appeared unrelated to braking force. </p>","PeriodicalId":7167,"journal":{"name":"Acta physiologica Hungarica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1556/APhysiol.101.2014.009","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta physiologica Hungarica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/APhysiol.101.2014.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The study was aimed to investigate the reproducibility of performance parameters obtained from 10-s maximal cycling effort against different braking forces in young adult athletes. The sample (n = 48) included male athletes aged 18.9-29.9 years (175.5 ± 6.9 cm, 76.2 ± 10.1 kg). The exercise protocol was performed in a cycle-ergometer against a random braking force (4% to 11% of body mass). Intra-individual variation was examined from repeated tests within one week. Descriptive statistics were computed and differences between sessions were tested using paired t-test. The coefficient of correlation between repeated measures, technical error of measurement (TEM), coefficient of variation and ICC were calculated. Agreement between trials was examined using the Bland-Altman procedure. Mean values of peak power were relatively stable when obtained from sampling rates of 50 Hz and ranged between 1068 watt and 1082 watt (t(47) = 1.149, p = 0.256, ES-r = 0.165) or while corresponding to a sampling rate of 1 Hz (t(47) = 0.742, p = 0.462, ES-r = 0.107). Correlations between repeated measures were high (+0.907, 95% CI: +0.839 to +0.947) and TEM about 59.3 watt (%CV = 5.52%; ICC = 0.951, 95% CI: 0.912 to 0.972). The present study suggests that reproducibility of peak power in male adult athletes tended to be acceptable and within individual error appeared unrelated to braking force.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用不同采样率在10秒循环最大努力期间峰值功率输出的再现性。
本研究旨在探讨年轻成年运动员在不同制动力下10-s最大循环努力所获得的性能参数的可重复性。48例男性运动员,年龄18.9 ~ 29.9岁(175.5±6.9 cm, 76.2±10.1 kg)。运动方案在一个随机制动力(体重的4%至11%)的自行车测力仪中进行。在一周内通过重复测试检查个体内变异。计算描述性统计数据,并使用配对t检验检验会话之间的差异。计算了重复测量的相关系数、技术测量误差(TEM)、变异系数和ICC。使用Bland-Altman程序检查试验之间的一致性。当采样率为50 Hz时,峰值功率的平均值相对稳定,在1068瓦至1082瓦之间(t(47) = 1.149, p = 0.256, ES-r = 0.165)或对应于采样率为1 Hz时(t(47) = 0.742, p = 0.462, ES-r = 0.107)。重复测量之间的相关性很高(+0.907,95% CI: +0.839 ~ +0.947), TEM约为59.3瓦特(%CV = 5.52%;ICC = 0.951, 95% CI: 0.912 ~ 0.972)。目前的研究表明,男性成年运动员的峰值功率的再现性往往是可以接受的,在个人误差似乎与制动力无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Acta physiologica Hungarica
Acta physiologica Hungarica 医学-生理学
自引率
0.00%
发文量
0
审稿时长
6.0 months
期刊最新文献
Comparative animal study of the antinociceptive efficacy of lamotrigine and gabapentin for the management of pain. Lactation protects against myocardial ischemia-reperfusion injury in rats. The acute muscular effects of cycling with and without different degrees of blood flow restriction. Preventive effects of garlic (Allium sativum) on oxidative stress and histopathology of cardiac tissue in streptozotocin-induced diabetic rats. Effect of 6 weeks of whole body vibration training on total and segmental body composition in healthy young adults.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.