{"title":"Cost-Saving Early Diagnosis of Functional Pain in Nonmalignant Pain: A Noninferiority Study of Diagnostic Accuracy.","authors":"Rafael J A Cámara,&nbsp;Christian Merz,&nbsp;Barbara Wegmann,&nbsp;Stefanie Stauber,&nbsp;Roland von Känel,&nbsp;Niklaus Egloff","doi":"10.1155/2016/5964250","DOIUrl":null,"url":null,"abstract":"<p><p>Objectives. We compared two index screening tests for early diagnosis of functional pain: pressure pain measurement by electronic diagnostic equipment, which is accurate but too specialized for primary health care, versus peg testing, which is cost-saving and more easily manageable but of unknown sensitivity and specificity. Early distinction of functional (altered pain perception; nervous sensitization) from neuropathic or nociceptive pain improves pain management. Methods. Clinicians blinded for the index screening tests assessed the reference standard of this noninferiority diagnostic accuracy study, namely, comprehensive medical history taking with all previous findings and treatment outcomes. All consenting patients referred to a university hospital for nonmalignant musculoskeletal pain participated. The main analysis compared the receiver operating characteristic (ROC) curves of both index screening tests. Results. The area under the ROC curve for peg testing was not inferior to that of electronic equipment: it was at least 95% as large for finger measures (two-sided p = 0.038) and at least equally as large for ear measures (two-sided p = 0.003). Conclusions. Routine diagnostic testing by peg, which is accessible for general practitioners, is at least as accurate as specialized equipment. This may shorten time-to-treatment in general practices, thereby improving the prognosis and quality of life. </p>","PeriodicalId":19786,"journal":{"name":"Pain Research and Treatment","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2016/5964250","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pain Research and Treatment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2016/5964250","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/3/21 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 7

Abstract

Objectives. We compared two index screening tests for early diagnosis of functional pain: pressure pain measurement by electronic diagnostic equipment, which is accurate but too specialized for primary health care, versus peg testing, which is cost-saving and more easily manageable but of unknown sensitivity and specificity. Early distinction of functional (altered pain perception; nervous sensitization) from neuropathic or nociceptive pain improves pain management. Methods. Clinicians blinded for the index screening tests assessed the reference standard of this noninferiority diagnostic accuracy study, namely, comprehensive medical history taking with all previous findings and treatment outcomes. All consenting patients referred to a university hospital for nonmalignant musculoskeletal pain participated. The main analysis compared the receiver operating characteristic (ROC) curves of both index screening tests. Results. The area under the ROC curve for peg testing was not inferior to that of electronic equipment: it was at least 95% as large for finger measures (two-sided p = 0.038) and at least equally as large for ear measures (two-sided p = 0.003). Conclusions. Routine diagnostic testing by peg, which is accessible for general practitioners, is at least as accurate as specialized equipment. This may shorten time-to-treatment in general practices, thereby improving the prognosis and quality of life.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
功能性疼痛在非恶性疼痛中的早期诊断:诊断准确性的非劣效性研究。
目标。我们比较了两种用于功能性疼痛早期诊断的指标筛选试验:通过电子诊断设备测量压痛,这是准确的,但对初级卫生保健来说过于专业化;与peg测试相比,peg测试更节省成本,更容易管理,但敏感性和特异性未知。早期区分功能性疼痛知觉改变;神经性或伤害性疼痛的神经致敏可改善疼痛管理。方法。盲法进行指标筛选试验的临床医生评估本非劣效性诊断准确性研究的参考标准,即综合病史,包括所有既往发现和治疗结果。所有因非恶性肌肉骨骼疼痛转介到大学医院的患者都参与了研究。主要分析比较两种指标筛选试验的受试者工作特征(ROC)曲线。结果。peg检测的ROC曲线下面积并不逊于电子设备:手指测量的面积至少为95%(双面p = 0.038),耳朵测量的面积至少为95%(双面p = 0.003)。结论。常规诊断测试的peg,这是可访问的全科医生,至少是一样准确的专业设备。这可能缩短一般治疗的时间,从而改善预后和生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Pain Research and Treatment
Pain Research and Treatment Medicine-Anesthesiology and Pain Medicine
CiteScore
3.60
自引率
0.00%
发文量
0
期刊最新文献
Efficacy of the LED Red Light Therapy in the Treatment of Temporomandibular Disorders: Double Blind Randomized Controlled Trial. Factors Associated with Postoperative Pain among Patients after Cardiac Surgery in the Tertiary Care Teaching Hospital of Karachi, Pakistan. Lornoxicam with Low-Dose Ketamine versus Pethidine to Control Pain of Acute Renal Colic. Cryotherapy Reduced Postoperative Pain in Gynecologic Surgery: A Randomized Controlled Trial. Challenges in the Analysis of Longitudinal Pain Data: Practical Lessons from a Randomized Trial of Annular Closure in Lumbar Disc Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1