Pocket-Sized Echocardiography Devices: One Stop Shop Service?

Journal of cardiovascular ultrasound Pub Date : 2016-03-01 Epub Date: 2016-03-24 DOI:10.4250/jcu.2016.24.1.1
Andreas Seraphim, Stavroula A Paschou, Julia Grapsa, Petros Nihoyannopoulos
{"title":"Pocket-Sized Echocardiography Devices: One Stop Shop Service?","authors":"Andreas Seraphim,&nbsp;Stavroula A Paschou,&nbsp;Julia Grapsa,&nbsp;Petros Nihoyannopoulos","doi":"10.4250/jcu.2016.24.1.1","DOIUrl":null,"url":null,"abstract":"<p><p>The introduction of portable, pocket-sized echocardiography devices in various healthcare systems has raised new questions with regards to their realistic use in clinical practice. Several studies have already attempted to provide information regarding their safety and diagnostic potential, the training required to operate them, as well as their direct comparison with standard echocardiography machines. This manuscript is a review of the literature of the documents or position papers which employ the use of pocket or handheld devices. Following review of the literature, we suggest that these miniaturized devices can provide a valuable diagnostic tool that can complement and improve the diagnostic yield of clinical examination. When operated by appropriately trained professionals, they can provide a limited but very reliable echocardiographic assessment. Pocket-sized echocardiography is a part of physical examination and should not be considered a complete echocardiographic scan. Optimal training is required for the smooth operation of handheld echocardiography. </p>","PeriodicalId":88913,"journal":{"name":"Journal of cardiovascular ultrasound","volume":"24 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4250/jcu.2016.24.1.1","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiovascular ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4250/jcu.2016.24.1.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2016/3/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

The introduction of portable, pocket-sized echocardiography devices in various healthcare systems has raised new questions with regards to their realistic use in clinical practice. Several studies have already attempted to provide information regarding their safety and diagnostic potential, the training required to operate them, as well as their direct comparison with standard echocardiography machines. This manuscript is a review of the literature of the documents or position papers which employ the use of pocket or handheld devices. Following review of the literature, we suggest that these miniaturized devices can provide a valuable diagnostic tool that can complement and improve the diagnostic yield of clinical examination. When operated by appropriately trained professionals, they can provide a limited but very reliable echocardiographic assessment. Pocket-sized echocardiography is a part of physical examination and should not be considered a complete echocardiographic scan. Optimal training is required for the smooth operation of handheld echocardiography.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
袖珍超声心动图设备:一站式服务?
在各种医疗保健系统中引入便携式、口袋大小的超声心动图设备,就其在临床实践中的实际应用提出了新的问题。一些研究已经试图提供有关其安全性和诊断潜力的信息,操作它们所需的培训,以及它们与标准超声心动图机的直接比较。这份手稿是文献的回顾或立场文件,采用口袋或手持设备的使用。根据文献回顾,我们认为这些小型装置可以提供有价值的诊断工具,可以补充和提高临床检查的诊断率。当由受过适当训练的专业人员操作时,它们可以提供有限但非常可靠的超声心动图评估。口袋大小的超声心动图是身体检查的一部分,不应该被认为是一个完整的超声心动图扫描。手持式超声心动图的顺利操作需要最佳的训练。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Long Term Outcomes of Left Atrial Reservoir Function in Children with a History of Kawasaki Disease. Diagnosis, Treatment, and Prevention of Cardiovascular Toxicity Related to Anti-Cancer Treatment in Clinical Practice: An Opinion Paper from the Working Group on Cardio-Oncology of the Korean Society of Echocardiography. Impact of a Geometric Correction for Proximal Flow Constraint on the Assessment of Mitral Regurgitation Severity Using the Proximal Flow Convergence Method. Recurrent Acute Myocardial Infarction Caused by Intra-cardiac Metastatic Undifferentiated Pleomorphic Sarcoma during Cancer Treatment. A Rare Case of Left Ventricular Noncompaction in LEOPARD Syndrome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1