Phase detection limits in off-axis electron holography from pixelated detectors: gain variations, geometric distortion and failure of reference-hologram correction
{"title":"Phase detection limits in off-axis electron holography from pixelated detectors: gain variations, geometric distortion and failure of reference-hologram correction","authors":"Martin Hÿtch;Christophe Gatel","doi":"10.1093/jmicro/dfaa044","DOIUrl":null,"url":null,"abstract":"We investigate the effect that recording off-axis electron holograms on pixelated detectors, such as charge-coupled devices (CCD) and direct-detection devices (DDD), can have on measured amplitudes and phases. Theory will be developed for the case of perfectly uniform interference fringes illuminating an imperfect detector with gain variations and pixel displacements. We will show that both these types of defect produce a systematic noise in the phase images that depends on the position of the holographic fringes with respect to the detector. Subtracting a reference hologram from the object hologram will therefore not remove the phase noise if the initial phases of the two holograms do not coincide exactly. Another finding is that pi-shifted holograms are much less affected by gain variations but show no improvement concerning geometric distortions. The resulting phase errors will be estimated and simulations presented that confirm the theoretical developments.","PeriodicalId":18515,"journal":{"name":"Microscopy","volume":"70 1","pages":"47-58"},"PeriodicalIF":1.8000,"publicationDate":"2020-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/jmicro/dfaa044","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/9433131/","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
We investigate the effect that recording off-axis electron holograms on pixelated detectors, such as charge-coupled devices (CCD) and direct-detection devices (DDD), can have on measured amplitudes and phases. Theory will be developed for the case of perfectly uniform interference fringes illuminating an imperfect detector with gain variations and pixel displacements. We will show that both these types of defect produce a systematic noise in the phase images that depends on the position of the holographic fringes with respect to the detector. Subtracting a reference hologram from the object hologram will therefore not remove the phase noise if the initial phases of the two holograms do not coincide exactly. Another finding is that pi-shifted holograms are much less affected by gain variations but show no improvement concerning geometric distortions. The resulting phase errors will be estimated and simulations presented that confirm the theoretical developments.
期刊介绍:
Microscopy, previously Journal of Electron Microscopy, promotes research combined with any type of microscopy techniques, applied in life and material sciences. Microscopy is the official journal of the Japanese Society of Microscopy.