Estimating the Haemodynamic Streamline Vena Contracta as the Effective Orifice Area Measured from Reconstructed Multislice Phase-contrast MR Images for Patients with Moderately Accelerated Aortic Stenosis.

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2022-10-01 Epub Date: 2021-07-30 DOI:10.2463/mrms.mp.2021-0001
Yu Hohri, Keiichi Itatani, Akiko Matsuo, Yoshiaki Komori, Takeshi Okamoto, Tomoyuki Goto, Takuma Kobayashi, Takeshi Hiramatsu, Shohei Miyazaki, Teruyasu Nishino, Hitoshi Yaku
{"title":"Estimating the Haemodynamic Streamline Vena Contracta as the Effective Orifice Area Measured from Reconstructed Multislice Phase-contrast MR Images for Patients with Moderately Accelerated Aortic Stenosis.","authors":"Yu Hohri,&nbsp;Keiichi Itatani,&nbsp;Akiko Matsuo,&nbsp;Yoshiaki Komori,&nbsp;Takeshi Okamoto,&nbsp;Tomoyuki Goto,&nbsp;Takuma Kobayashi,&nbsp;Takeshi Hiramatsu,&nbsp;Shohei Miyazaki,&nbsp;Teruyasu Nishino,&nbsp;Hitoshi Yaku","doi":"10.2463/mrms.mp.2021-0001","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In aortic stenosis (AS), the discrepancy between moderately accelerated flow and effective orifice area (EOA) continues to pose a challenge. We developed a method of measuring the vena contracta area as hemodynamic EOA using cardiac MRI focusing on AS patients with a moderately accelerated flow to solve the problem that AS severity can currently be determined only by echocardiography.</p><p><strong>Methods: </strong>We investigated 40 patients with a peak transvalvular velocity > 3.0 m/s on transthoracic echocardiography (TTE). The patients were divided into highly accelerated and moderately accelerated AS groups according to whether or not the peak transvalvular velocity was ≥ 4.0 m/s. From the multislice 2D cine phase-contrast MRI data, the cross-sectional area of the vena contracta of the reconstructed streamline in the Valsalva sinus was defined as MRI-EOAs. Patient symptoms and echocardiography data, including EOA (defined as TTE-EOA), were derived from the continuity equation using TTE.</p><p><strong>Results: </strong>All participants in the highly accelerated AS group (n = 19) showed a peak velocity ≥ 4.0 m/s in MRI. Eleven patients in the moderately accelerated AS group (n = 21) had a TTE-EOA < 1.00 cm<sup>2</sup>. In the moderately accelerated AS group, MRI-EOAs demonstrated a strong correlation with TTE-EOAs (r = 0.76, P < 0.01). Meanwhile, in the highly accelerated AS group, MRI-EOAs demonstrated positivity but a moderate correlation with TTE-EOAs (r = 0.63, P = 0.004). MRI-EOAs were overestimated compared to TTE-EOAs. In terms of the moderately accelerated AS group, the best cut-off value for MRI-EOAs was < 1.23 cm<sup>2</sup>, compatible with TTE-EOAs < 1.00 cm<sup>2</sup>, with an excellent prediction of the New York Heart Association classification ≥ III (sensitivity 87.5%, specificity 76.9%).</p><p><strong>Conclusion: </strong>MRI-EOAs may be an alternative to conventional echocardiography for patients with moderately accelerated AS, especially those with discordant echocardiographic parameters.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"21 4","pages":"569-582"},"PeriodicalIF":4.6000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/13/14/mrms-21-569.PMC9618929.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2021-0001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/7/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: In aortic stenosis (AS), the discrepancy between moderately accelerated flow and effective orifice area (EOA) continues to pose a challenge. We developed a method of measuring the vena contracta area as hemodynamic EOA using cardiac MRI focusing on AS patients with a moderately accelerated flow to solve the problem that AS severity can currently be determined only by echocardiography.

Methods: We investigated 40 patients with a peak transvalvular velocity > 3.0 m/s on transthoracic echocardiography (TTE). The patients were divided into highly accelerated and moderately accelerated AS groups according to whether or not the peak transvalvular velocity was ≥ 4.0 m/s. From the multislice 2D cine phase-contrast MRI data, the cross-sectional area of the vena contracta of the reconstructed streamline in the Valsalva sinus was defined as MRI-EOAs. Patient symptoms and echocardiography data, including EOA (defined as TTE-EOA), were derived from the continuity equation using TTE.

Results: All participants in the highly accelerated AS group (n = 19) showed a peak velocity ≥ 4.0 m/s in MRI. Eleven patients in the moderately accelerated AS group (n = 21) had a TTE-EOA < 1.00 cm2. In the moderately accelerated AS group, MRI-EOAs demonstrated a strong correlation with TTE-EOAs (r = 0.76, P < 0.01). Meanwhile, in the highly accelerated AS group, MRI-EOAs demonstrated positivity but a moderate correlation with TTE-EOAs (r = 0.63, P = 0.004). MRI-EOAs were overestimated compared to TTE-EOAs. In terms of the moderately accelerated AS group, the best cut-off value for MRI-EOAs was < 1.23 cm2, compatible with TTE-EOAs < 1.00 cm2, with an excellent prediction of the New York Heart Association classification ≥ III (sensitivity 87.5%, specificity 76.9%).

Conclusion: MRI-EOAs may be an alternative to conventional echocardiography for patients with moderately accelerated AS, especially those with discordant echocardiographic parameters.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
中度加速主动脉狭窄患者重建多层相衬MR图像中血流动力学流线静脉收缩有效孔口面积的估算。
目的:在主动脉狭窄(AS)中,适度加速血流与有效孔口面积(EOA)之间的差异仍然是一个挑战。我们开发了一种测量静脉收缩面积作为血流动力学EOA的方法,使用心脏MRI聚焦于中度血流加速的as患者,以解决目前只能通过超声心动图确定as严重程度的问题。方法:对40例经胸超声心动图(TTE)峰值经瓣速度> 3.0 m/s的患者进行研究。根据经瓣速度峰值是否≥4.0 m/s分为高加速组和中加速组。从多层2D电影相对比MRI数据中,将Valsalva窦重构流线收缩静脉的横截面积定义为MRI- eoa。患者症状和超声心动图数据,包括EOA(定义为te -EOA),由使用TTE的连续性方程导出。结果:高加速AS组(n = 19) MRI峰值速度均≥4.0 m/s。中度加速AS组11例患者(n = 21) te - eoa < 1.00 cm2。中度加速AS组MRI-EOAs与te - eoas相关性较强(r = 0.76, P < 0.01)。高加速AS组MRI-EOAs呈阳性,但与te - eoas呈正相关(r = 0.63, P = 0.004)。与te - eoas相比,MRI-EOAs被高估。中度加速AS组MRI-EOAs的最佳临界值< 1.23 cm2,与te - eoas < 1.00 cm2相一致,对纽约心脏协会分级≥III的预测效果良好(敏感性87.5%,特异性76.9%)。结论:对于中度加速AS患者,尤其是超声心动图参数不一致的患者,MRI-EOAs可能是常规超声心动图的替代选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1