Blockage of CSF Outflow in Rats after Deep Cervical Lymph Node Ligation Observed Using Gd-based MR Imaging.

IF 2.5 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Magnetic Resonance in Medical Sciences Pub Date : 2024-10-01 Epub Date: 2023-05-30 DOI:10.2463/mrms.mp.2023-0023
Naoya Kinota, Hiroyuki Kameda, Bai Xiawei, Takaaki Fujii, Daisuke Kato, Bunya Takahashi, Ryo Morita, Daisuke Abo, Ryusei Majima, Hiroshi Ishii, Kazuyuki Minowa, Kohsuke Kudo
{"title":"Blockage of CSF Outflow in Rats after Deep Cervical Lymph Node Ligation Observed Using Gd-based MR Imaging.","authors":"Naoya Kinota, Hiroyuki Kameda, Bai Xiawei, Takaaki Fujii, Daisuke Kato, Bunya Takahashi, Ryo Morita, Daisuke Abo, Ryusei Majima, Hiroshi Ishii, Kazuyuki Minowa, Kohsuke Kudo","doi":"10.2463/mrms.mp.2023-0023","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate whether deep cervical lymph node (DCLN) ligation alters intracranial cerebrospinal fluid (CSF) tracer dynamics and outflow using a rat model with intrathecal dynamic contrast-enhanced (DCE) MRI.</p><p><strong>Methods: </strong>Six bilateral DCLN-ligated and six sham-operated rats were subjected to DCE MRI with Gd-BTDO3A, and dynamic T1-weighted images were acquired. ROIs were collected from the CSF at the C1 level (CSF_C1), CSF between the olfactory bulbs (CSF_OB), CSF at the pituitary recess (CSF_PitR), and CSF at the pineal recess (CSF_PinR), upper nasal turbinate (UNT), olfactory bulbs, cerebrum, and the jugular region. Time-intensity curves were evaluated, and the maximum slope, peak timing, peak signal ratio, and elimination half-life for the four CSF ROIs and UNT were calculated and compared.</p><p><strong>Results: </strong>Delayed tracer arrival in the rostral CSF space and the nasal cavity with tracer retention in the ventral CSF space were observed in the ligation group. The maximum slopes were smaller in the ligation group at UNT (sham: 0.075 ± 0.0061, ligation: 0.044 ± 0.0086/min, P = 0.011). A significant difference was not detected in peak timings. The peak signal ratio values were lower in the ligation group at UNT (sham: 2.12 ± 0.19, ligation: 1.72 ± 0.11, P = 0.011). The elimination half-life was delayed in the ligation group at CSF_C1 (sham: 30.5 ± 2.70, ligation: 44.4 ± 12.6 min, P = 0.043), CSF_OB (sham: 30.2 ± 2.67, ligation: 44.8 ± 7.47 min, P = 0.021), and CSF_PitR (sham: 30.2 ± 2.49, ligation: 41.3 ± 7.57 min, P = 0.021).</p><p><strong>Conclusion: </strong>The DCLN ligation in rats blocked CSF outflow into the nasal cavity and caused CSF retention.</p>","PeriodicalId":18119,"journal":{"name":"Magnetic Resonance in Medical Sciences","volume":" ","pages":"449-459"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11447471/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic Resonance in Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.mp.2023-0023","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/5/30 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate whether deep cervical lymph node (DCLN) ligation alters intracranial cerebrospinal fluid (CSF) tracer dynamics and outflow using a rat model with intrathecal dynamic contrast-enhanced (DCE) MRI.

Methods: Six bilateral DCLN-ligated and six sham-operated rats were subjected to DCE MRI with Gd-BTDO3A, and dynamic T1-weighted images were acquired. ROIs were collected from the CSF at the C1 level (CSF_C1), CSF between the olfactory bulbs (CSF_OB), CSF at the pituitary recess (CSF_PitR), and CSF at the pineal recess (CSF_PinR), upper nasal turbinate (UNT), olfactory bulbs, cerebrum, and the jugular region. Time-intensity curves were evaluated, and the maximum slope, peak timing, peak signal ratio, and elimination half-life for the four CSF ROIs and UNT were calculated and compared.

Results: Delayed tracer arrival in the rostral CSF space and the nasal cavity with tracer retention in the ventral CSF space were observed in the ligation group. The maximum slopes were smaller in the ligation group at UNT (sham: 0.075 ± 0.0061, ligation: 0.044 ± 0.0086/min, P = 0.011). A significant difference was not detected in peak timings. The peak signal ratio values were lower in the ligation group at UNT (sham: 2.12 ± 0.19, ligation: 1.72 ± 0.11, P = 0.011). The elimination half-life was delayed in the ligation group at CSF_C1 (sham: 30.5 ± 2.70, ligation: 44.4 ± 12.6 min, P = 0.043), CSF_OB (sham: 30.2 ± 2.67, ligation: 44.8 ± 7.47 min, P = 0.021), and CSF_PitR (sham: 30.2 ± 2.49, ligation: 41.3 ± 7.57 min, P = 0.021).

Conclusion: The DCLN ligation in rats blocked CSF outflow into the nasal cavity and caused CSF retention.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用钆基磁共振成像观察深颈部淋巴结结扎后大鼠脑脊液流出受阻情况
目的:通过大鼠鞘内动态对比增强(DCE)磁共振成像(MRI)研究颈深淋巴结(DCLN)结扎是否会改变颅内脑脊液(CSF)示踪剂的动态变化和流出:对 6 只双侧 DCLN 结扎大鼠和 6 只假手术大鼠进行 Gd-BTDO3A 的 DCE MRI 检查,并获取动态 T1 加权图像。从C1水平的CSF(CSF_C1)、嗅球之间的CSF(CSF_OB)、垂体凹陷处的CSF(CSF_PitR)、松果体凹陷处的CSF(CSF_PinR)、上鼻甲(UNT)、嗅球、大脑和颈静脉区域采集ROI。评估了时间强度曲线,计算并比较了四个 CSF ROI 和 UNT 的最大斜率、峰值时间、峰值信号比和消除半衰期:结果:结扎组观察到示踪剂延迟到达喙侧 CSF 间隙和鼻腔,并在腹侧 CSF 间隙滞留。结扎组在 UNT 时的最大斜率较小(假性:0.075 ± 0.0061,结扎:0.044 ± 0.0086/分钟,P = 0.011)。在峰值时间上未发现明显差异。结扎组的 UNT 峰值信号比值较低(假体:2.12 ± 0.19,结扎:1.72 ± 0.11,P = 0.011)。结扎组在 CSF_C1(假:30.5 ± 2.70,结扎:44.4 ± 12.6 分钟,P = 0.043)、CSF_OB(假:30.2 ± 2.67,结扎:44.8 ± 7.47 分钟,P = 0.021)和 CSF_PitR (假:30.2 ± 2.49,结扎:41.3 ± 7.57 分钟,P = 0.021)处的消除半衰期延迟:结论:对大鼠进行 DCLN 结扎可阻止 CSF 流出鼻腔并导致 CSF 滞留。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Magnetic Resonance in Medical Sciences
Magnetic Resonance in Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
5.80
自引率
20.00%
发文量
71
审稿时长
>12 weeks
期刊介绍: Magnetic Resonance in Medical Sciences (MRMS or Magn Reson Med Sci) is an international journal pursuing the publication of original articles contributing to the progress of magnetic resonance in the field of biomedical sciences including technical developments and clinical applications. MRMS is an official journal of the Japanese Society for Magnetic Resonance in Medicine (JSMRM).
期刊最新文献
Blockage of CSF Outflow in Rats after Deep Cervical Lymph Node Ligation Observed Using Gd-based MR Imaging. Physical Exercise Alters Egress Pathways for Intrinsic CSF Outflow: An Investigation Performed with Spin-labeling MR Imaging. Aliphatic and Olefinic Fat Suppression in the Orbit Using Polarity-altered Spectral and Spatial Selective Acquisition (PASTA) with Opposed Phase. Thin-slice Two-dimensional T2-weighted Imaging with Deep Learning-based Reconstruction: Improved Lesion Detection in the Brain of Patients with Multiple Sclerosis. Breath-hold High-resolution T1-weighted Gradient Echo Liver MR Imaging with Compressed Sensing Obtained during the Gadoxetic Acid-enhanced Hepatobiliary Phase: Image Quality and Lesion Visibility Compared with a Standard T1-weighted Sequence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1