{"title":"Hydrogen-rich bath with nano-sized bubbles improves antioxidant capacity based on oxygen radical absorbing and inflammation levels in human serum.","authors":"Yoshiharu Tanaka, Li Xiao, Nobuhiko Miwa","doi":"10.4103/2045-9912.330692","DOIUrl":null,"url":null,"abstract":"<p><p>This study compared the effects of hydrogen-water (HW) bath on the oxygen radical absorption-based antioxidant capacity and the inflammatory indicator, C-reactive protein (CRP), in serum between healthy volunteers and inflammatory/collagen disease-patients. The HW bath apparatus supplied nano-bubbles with a diameter of 110 ± 10 nm and 338-682 μg/L of dissolved hydrogen after 120 minutes electrolysis, and nano-bubbles increased to 9.91 × 10<sup>7</sup>/mL along with the increase of correlative dissolved hydrogen. Ten-minute HW bath increased the oxygen radical absorption-based antioxidant capacity to 110.9 ± 9.2% at post-bathing 120 minutes, although unaltered with 10-minute normal water bath at 40°C in healthy subjects. The CRP level was repressed to 70.2 ± 12.1% at 120 minutes after HW bath, although rather increased for normal water bath. In the patients with connective tissue diseases, the CRP level was repressed to 3-24% upon 9 days to 4 months of HW bathing. In another six patients with diverse autoimmune-related diseases, upon daily HW bathing as long as 2-25 months, the pre-bathing CRP level of 5.31 mg/dL decreased to 0.24 mg/dL being within the standard-range, with relief of visible inflammatory symptoms for some cases. Thus, the HW bath with high-density nano-bubbles has beneficial effects on serum antioxidant capacity, inflammation, and the skin appearance. The study was approved by the Committee of Ethics, Japanese Center of Anti-Aging Medical Sciences (Authorization No. H-15-03-2, on January 15, 2019), which was a non-profitable organization officially authenticated by the Hiroshima Prefecture Government of Japan.</p>","PeriodicalId":18559,"journal":{"name":"Medical Gas Research","volume":"12 3","pages":"91-99"},"PeriodicalIF":3.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/7e/8c/MGR-12-91.PMC8690854.pdf","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Gas Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/2045-9912.330692","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 2
Abstract
This study compared the effects of hydrogen-water (HW) bath on the oxygen radical absorption-based antioxidant capacity and the inflammatory indicator, C-reactive protein (CRP), in serum between healthy volunteers and inflammatory/collagen disease-patients. The HW bath apparatus supplied nano-bubbles with a diameter of 110 ± 10 nm and 338-682 μg/L of dissolved hydrogen after 120 minutes electrolysis, and nano-bubbles increased to 9.91 × 107/mL along with the increase of correlative dissolved hydrogen. Ten-minute HW bath increased the oxygen radical absorption-based antioxidant capacity to 110.9 ± 9.2% at post-bathing 120 minutes, although unaltered with 10-minute normal water bath at 40°C in healthy subjects. The CRP level was repressed to 70.2 ± 12.1% at 120 minutes after HW bath, although rather increased for normal water bath. In the patients with connective tissue diseases, the CRP level was repressed to 3-24% upon 9 days to 4 months of HW bathing. In another six patients with diverse autoimmune-related diseases, upon daily HW bathing as long as 2-25 months, the pre-bathing CRP level of 5.31 mg/dL decreased to 0.24 mg/dL being within the standard-range, with relief of visible inflammatory symptoms for some cases. Thus, the HW bath with high-density nano-bubbles has beneficial effects on serum antioxidant capacity, inflammation, and the skin appearance. The study was approved by the Committee of Ethics, Japanese Center of Anti-Aging Medical Sciences (Authorization No. H-15-03-2, on January 15, 2019), which was a non-profitable organization officially authenticated by the Hiroshima Prefecture Government of Japan.
期刊介绍:
Medical Gas Research is an open access journal which publishes basic, translational, and clinical research focusing on the neurobiology as well as multidisciplinary aspects of medical gas research and their applications to related disorders. The journal covers all areas of medical gas research, but also has several special sections. Authors can submit directly to these sections, whose peer-review process is overseen by our distinguished Section Editors: Inert gases - Edited by Xuejun Sun and Mark Coburn, Gasotransmitters - Edited by Atsunori Nakao and John Calvert, Oxygen and diving medicine - Edited by Daniel Rossignol and Ke Jian Liu, Anesthetic gases - Edited by Richard Applegate and Zhongcong Xie, Medical gas in other fields of biology - Edited by John Zhang. Medical gas is a large family including oxygen, hydrogen, carbon monoxide, carbon dioxide, nitrogen, xenon, hydrogen sulfide, nitrous oxide, carbon disulfide, argon, helium and other noble gases. These medical gases are used in multiple fields of clinical practice and basic science research including anesthesiology, hyperbaric oxygen medicine, diving medicine, internal medicine, emergency medicine, surgery, and many basic sciences disciplines such as physiology, pharmacology, biochemistry, microbiology and neurosciences. Due to the unique nature of medical gas practice, Medical Gas Research will serve as an information platform for educational and technological advances in the field of medical gas.