Usefulness of 99mTc-Pertechnetate SPECT-CT in Thyroid Tissue Volumetry: Phantom Studies and a Clinical Case Series.

IF 1.5 4区 医学 Q3 PHARMACOLOGY & PHARMACY Current radiopharmaceuticals Pub Date : 2022-01-01 DOI:10.2174/1874471015666220111145550
Enrico Calandri, Maria Teresa Giraudo, Roberta Sirovich, Antonella Ostan, Mirco Pultrone, Viviana Frantellizzi, Lucia Conversano, Paolo Bagnasacco, Sonya Gallina, Giuseppe De Vincentis
{"title":"Usefulness of 99mTc-Pertechnetate SPECT-CT in Thyroid Tissue Volumetry: Phantom Studies and a Clinical Case Series.","authors":"Enrico Calandri,&nbsp;Maria Teresa Giraudo,&nbsp;Roberta Sirovich,&nbsp;Antonella Ostan,&nbsp;Mirco Pultrone,&nbsp;Viviana Frantellizzi,&nbsp;Lucia Conversano,&nbsp;Paolo Bagnasacco,&nbsp;Sonya Gallina,&nbsp;Giuseppe De Vincentis","doi":"10.2174/1874471015666220111145550","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>An accurate measurement of the target volume is of primary importance in theragnostics of hyperthyroidism.</p><p><strong>Objective: </strong>Our purpose was to evaluate the accuracy of a threshold-based isocontour extraction procedure for thyroid tissue volumetry from SPECT-CT.</p><p><strong>Methods: </strong>Cylindrical vials with a fixed volume of 99mTcO4 at different activities were inserted into a neck phantom in two different thickness settings. Images were acquired by orienting the phantom in different positions, i.e., 40 planar images and 40 SPECT-CT. The fixed values of the isocontouring threshold for SPECT and SPECT-CT were calculated by means of linear and spline regression models. Mean, Median, Standard Deviation, Standard Error, Mean Absolute Percentage Error and Root Mean-Square Error were computed. Any difference between the planar method, SPECT and SPECT-CT and the effective volume was evaluated by means of ANOVA and posthoc tests. Moreover, planar and SPECT-CT acquisitions were performed in 8 patients with hyperthyroidism, considering relevant percentage differences greater than > 20% from the CT gold standard.</p><p><strong>Results: </strong>Concerning phantom studies, the planar method shows higher values of each parameter than the other two methods. SPECT-CT shows lower variability. However, no significant differences were observed between SPECT and SPECT-CT measurements. In patients, relevant differences were found in 7 out of 9 lesions with the planar method, in 6 lesions with SPECT, but in only one with SPECT-CT.</p><p><strong>Conclusion: </strong>Our study confirms the superiority of SPECT in volume measurement if compared with the planar method. A more accurate measurement can be obtained from SPECT-CT.</p>","PeriodicalId":10991,"journal":{"name":"Current radiopharmaceuticals","volume":"15 3","pages":"205-217"},"PeriodicalIF":1.5000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current radiopharmaceuticals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2174/1874471015666220111145550","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: An accurate measurement of the target volume is of primary importance in theragnostics of hyperthyroidism.

Objective: Our purpose was to evaluate the accuracy of a threshold-based isocontour extraction procedure for thyroid tissue volumetry from SPECT-CT.

Methods: Cylindrical vials with a fixed volume of 99mTcO4 at different activities were inserted into a neck phantom in two different thickness settings. Images were acquired by orienting the phantom in different positions, i.e., 40 planar images and 40 SPECT-CT. The fixed values of the isocontouring threshold for SPECT and SPECT-CT were calculated by means of linear and spline regression models. Mean, Median, Standard Deviation, Standard Error, Mean Absolute Percentage Error and Root Mean-Square Error were computed. Any difference between the planar method, SPECT and SPECT-CT and the effective volume was evaluated by means of ANOVA and posthoc tests. Moreover, planar and SPECT-CT acquisitions were performed in 8 patients with hyperthyroidism, considering relevant percentage differences greater than > 20% from the CT gold standard.

Results: Concerning phantom studies, the planar method shows higher values of each parameter than the other two methods. SPECT-CT shows lower variability. However, no significant differences were observed between SPECT and SPECT-CT measurements. In patients, relevant differences were found in 7 out of 9 lesions with the planar method, in 6 lesions with SPECT, but in only one with SPECT-CT.

Conclusion: Our study confirms the superiority of SPECT in volume measurement if compared with the planar method. A more accurate measurement can be obtained from SPECT-CT.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
99mtc -高techate SPECT-CT在甲状腺组织体积测量中的作用:幻影研究和临床病例系列。
背景:靶体积的准确测量在甲状腺机能亢进的诊断中是至关重要的。目的:我们的目的是评估基于阈值的等轮廓提取程序甲状腺组织体积从SPECT-CT的准确性。方法:将固定体积的99mTcO4圆柱形小瓶以不同的活度插入两种不同厚度的颈模中。将幻体定位在不同位置获取图像,即平面图像40张,SPECT-CT图像40张。利用线性和样条回归模型计算SPECT和SPECT- ct等轮廓阈值的固定值。计算平均值、中位数、标准差、标准误差、平均绝对百分比误差和均方根误差。平面法、SPECT和SPECT- ct与有效体积之间的差异通过方差分析和事后检验进行评价。此外,考虑到与CT金标准的相关百分比差异大于> 20%,对8例甲状腺功能亢进患者进行了平面和SPECT-CT采集。结果:在幻影研究中,平面法的各参数值均高于其他两种方法。SPECT-CT显示较低的变异性。然而,在SPECT和SPECT- ct测量之间没有观察到显著差异。在9例患者中,平面法有7例发现相关差异,SPECT有6例发现相关差异,SPECT- ct只有1例。结论:本研究证实了SPECT在体积测量方面的优越性。SPECT-CT可以获得更精确的测量结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Current radiopharmaceuticals
Current radiopharmaceuticals PHARMACOLOGY & PHARMACY-
CiteScore
3.20
自引率
4.30%
发文量
43
期刊最新文献
Enhancing Ketoprofen Solubility: A Strategic Approach Using Solid Dispersion and Response Surface Methodology. Preclinical Aspects of [89Zr]Zr-DFO-Rituximab: A High Potential Agent for Immuno-PET Imaging. Apigenin's Influence on Inflammatory and Epigenetic Responses in Rat Lungs After Radiotherapy. An Analysis of the Radiosensitiser Applications in the Biomedical Field. Left Ventricular Wall Motion as an Additional Valuable Parameter in Diabetic Patients with Normal Myocardial Perfusion Imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1