Visual performance with multifocal corneal gas-permeable contact lenses in young adults: A pilot study

IF 2.2 Q2 OPHTHALMOLOGY Journal of Optometry Pub Date : 2022-10-01 DOI:10.1016/j.optom.2022.01.001
Muteb Alanazi , Patrick Caroline , Matthew Lampa , Maria Liu
{"title":"Visual performance with multifocal corneal gas-permeable contact lenses in young adults: A pilot study","authors":"Muteb Alanazi ,&nbsp;Patrick Caroline ,&nbsp;Matthew Lampa ,&nbsp;Maria Liu","doi":"10.1016/j.optom.2022.01.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>To evaluate the performance of four experimental multifocal gas permeable contact lens (MFGPCL) designs and their impact on visual function in young adults.</p></div><div><h3>Methods</h3><p>Seventeen young adults (age, 23.17 ± 4.48 years) enrolled in the study. Each participant was randomly assigned to wear two of four MFGPCL designs. They wore the first type of the assigned lens binocularly for one week and, after one week of washout period, wore another design on both eyes for another week. The four MFGPCL designs were as follows: design A (distance zone [DZ] 1.5 mm / add 3.0 D), B (DZ 1.5 mm / add 1.5 D), C (DZ 3.0 mm / add 3.0 D), and D (DZ 3.0 mm / add 1.5 D). Baseline visual acuity, contrast sensitivity function, and accommodation data were collected at baseline and repeated after one week of MFGPCL daily wear.</p></div><div><h3>Results</h3><p>Distance and near visual acuities were not significant affected with the four MFGPCL designs. Contrast sensitivity was significantly lower in design A across all measured spatial frequencies (<em>p</em> &lt; 0.05), with no significant impact from other designs on all frequencies. No significant effect was observed on accommodation measured at 33 cm (<em>p</em> &gt; 0.05).</p></div><div><h3>Conclusions</h3><p>Three of the investigated MFGPCL designs preserve satisfactory visual performance. Lens design A incorporated with higher add and smaller center zone diameter had a stronger impact on the visual performance.</p></div>","PeriodicalId":46407,"journal":{"name":"Journal of Optometry","volume":"15 4","pages":"Pages 305-312"},"PeriodicalIF":2.2000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/cf/5d/main.PMC9537242.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Optometry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1888429622000012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To evaluate the performance of four experimental multifocal gas permeable contact lens (MFGPCL) designs and their impact on visual function in young adults.

Methods

Seventeen young adults (age, 23.17 ± 4.48 years) enrolled in the study. Each participant was randomly assigned to wear two of four MFGPCL designs. They wore the first type of the assigned lens binocularly for one week and, after one week of washout period, wore another design on both eyes for another week. The four MFGPCL designs were as follows: design A (distance zone [DZ] 1.5 mm / add 3.0 D), B (DZ 1.5 mm / add 1.5 D), C (DZ 3.0 mm / add 3.0 D), and D (DZ 3.0 mm / add 1.5 D). Baseline visual acuity, contrast sensitivity function, and accommodation data were collected at baseline and repeated after one week of MFGPCL daily wear.

Results

Distance and near visual acuities were not significant affected with the four MFGPCL designs. Contrast sensitivity was significantly lower in design A across all measured spatial frequencies (p < 0.05), with no significant impact from other designs on all frequencies. No significant effect was observed on accommodation measured at 33 cm (p > 0.05).

Conclusions

Three of the investigated MFGPCL designs preserve satisfactory visual performance. Lens design A incorporated with higher add and smaller center zone diameter had a stronger impact on the visual performance.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
年轻人使用多焦点角膜透气性隐形眼镜的视力表现:一项初步研究
目的评价四种实验性多焦透气性隐形眼镜(MFGPCL)的性能及其对青少年视功能的影响。方法17例青壮年(23.17±4.48岁)入组研究。每个参与者被随机分配穿四种MFGPCL设计中的两种。他们用双眼戴第一种指定的镜片一周,经过一周的冲洗期后,再在两只眼睛上戴另一种设计的镜片一周。四种MFGPCL设计分别为:A(距离区[DZ] 1.5 mm /添加3.0 D)、B (DZ 1.5 mm /添加1.5 D)、C (DZ 3.0 mm /添加3.0 D)和D (DZ 3.0 mm /添加1.5 D)。在基线时收集基线视力、对比敏感度函数和调节数据,并在MFGPCL日常佩戴一周后重复。结果四种MFGPCL设计对远、近视力均无显著影响。在所有测量的空间频率上,设计A的对比敏感度显著降低(p <0.05),其他设计对所有频率没有显著影响。在33厘米处没有观察到明显的调节作用(p >0.05)。结论3种MFGPCL设计保持了满意的视觉效果。镜头设计A采用更高的添加量和更小的中心区直径,对视觉表现的影响更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Optometry
Journal of Optometry OPHTHALMOLOGY-
CiteScore
5.20
自引率
0.00%
发文量
60
审稿时长
66 days
期刊最新文献
Blue light stimulation of the optic nerve head reduces melatonin levels in rabbit posterior segment Effect of a vergence-accommodation conflict induced during a 30-minute Virtual Reality game on vergence-accommodation parameters and related symptoms Visual performance of a new trifocal intraocular lens design evaluated with a clinical adaptative optics visual simulator Analysis of patient referrals from primary care to ophthalmology. The role of the optometrist Corneal higher-order aberrations in different types of irregular cornea
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1