Detection of SARS-CoV-2 VOC-Omicron using commercial sample-to-answer real-time RT-PCR platforms and melting curve-based SNP assays

IF 1.6 Q4 INFECTIOUS DISEASES Journal of clinical virology plus Pub Date : 2022-08-01 DOI:10.1016/j.jcvp.2022.100091
Brian H.M. Sit , Kathy Hiu Laam Po , Yuk-Yam Cheung , Alan K. L. Tsang, Patricia K. L. Leung, J. Zheng, Alison Y. T. Lam, Edman T. K. Lam, Ken H. L. Ng, Rickjason C. W. Chan
{"title":"Detection of SARS-CoV-2 VOC-Omicron using commercial sample-to-answer real-time RT-PCR platforms and melting curve-based SNP assays","authors":"Brian H.M. Sit ,&nbsp;Kathy Hiu Laam Po ,&nbsp;Yuk-Yam Cheung ,&nbsp;Alan K. L. Tsang,&nbsp;Patricia K. L. Leung,&nbsp;J. Zheng,&nbsp;Alison Y. T. Lam,&nbsp;Edman T. K. Lam,&nbsp;Ken H. L. Ng,&nbsp;Rickjason C. W. Chan","doi":"10.1016/j.jcvp.2022.100091","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>The World Health Organization (WHO) had designated the SARS-CoV-2 lineage B.1.1.529 as the new Variant of Concern Omicron (VOC-Omicron) on 26<sup>th</sup> November 2021<sup>1</sup>. Real-time reverse transcription polymerase chain reaction (RT-PCR), single nucleotide polymorphisms (SNP) and whole genome sequencing (WGS) tests were widely employed to detect SARS-CoV-2 and its variant. Yet, the SARS-CoV-2 Omicron detection performance of commercial real-time RT-PCR platforms and SARS-CoV-2 spike SNP assays remain to be elucidated.</p></div><div><h3>Methods</h3><p>In the first part of this study, we evaluated the VOC-Omicron detection performance of three commercial RT-PCR sample-to-answer platforms i.e. Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems. The detection performances were compared to one commercial conventional real-time RT-PCR assay (TIB MOLBIOL LightMix Modular SARS and Wuhan CoV E-gene) and one in-house real-time RT-PCR assay targeting RNA-dependent RNA polymerase (RdRP) gene of SARS-CoV-2 in the WHO COVID-19 Reference Laboratory at Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, The Government of the Hong Kong Special Administrative Region. In the second part of this study, we evaluated the SNP detection performance of four TIB MOLBIOL melting curve-based assays (1. Spike S371L/S373P, 2. Spike E484A, 3. Spike E484K and 4. Spike N501Y) in clinical samples obtained from hospitalized COVID-19 patients in Hong Kong. The SNP results were compared to whole genome sequences generated by Illumina platform.</p></div><div><h3>Results</h3><p>The VOC-Omicron detection limits of three commercial sample-to-answer assays were tested to be ≤ 2.35 Log<sub>10</sub> dC/ml. The detection performances of the sample-to-answer platforms were comparable to the two tested conventional real-time RT-PCR assays. The test sensitivities of TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P assay and the Spike E484A assays were 100% and 96.6% respectively and the test specificities of both assays were 100%. An aberrant melting peak at Tm 42-44°C was observed when the specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay. Notably, the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike N501Y assay failed to detect the spike N501Y mutation of Omicron variant in the tested specimens.</p></div><div><h3>Conclusions</h3><p>The SARS-CoV-2 detection sensitivity of three commercial platforms, Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems were shown not to be impacted by the large number of mutations of VOC-Omicron. Also, the signature mutations i.e. Spike S371L/Spike S373P and Spike E484A in VOC-Omicron were correctly identified by the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P and VirSNiP SARS-CoV-2 Spike E484A assays. Unexpected findings including a shifted melting peak or absence of amplification curve/melting peak were observed when specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay and Spike N501Y assay, suggesting a potential alert for Omicron variant, prior confirmation by whole genome sequencing.</p></div>","PeriodicalId":73673,"journal":{"name":"Journal of clinical virology plus","volume":"2 3","pages":"Article 100091"},"PeriodicalIF":1.6000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9213017/pdf/","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical virology plus","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667038022000308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 9

Abstract

Objectives

The World Health Organization (WHO) had designated the SARS-CoV-2 lineage B.1.1.529 as the new Variant of Concern Omicron (VOC-Omicron) on 26th November 20211. Real-time reverse transcription polymerase chain reaction (RT-PCR), single nucleotide polymorphisms (SNP) and whole genome sequencing (WGS) tests were widely employed to detect SARS-CoV-2 and its variant. Yet, the SARS-CoV-2 Omicron detection performance of commercial real-time RT-PCR platforms and SARS-CoV-2 spike SNP assays remain to be elucidated.

Methods

In the first part of this study, we evaluated the VOC-Omicron detection performance of three commercial RT-PCR sample-to-answer platforms i.e. Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems. The detection performances were compared to one commercial conventional real-time RT-PCR assay (TIB MOLBIOL LightMix Modular SARS and Wuhan CoV E-gene) and one in-house real-time RT-PCR assay targeting RNA-dependent RNA polymerase (RdRP) gene of SARS-CoV-2 in the WHO COVID-19 Reference Laboratory at Public Health Laboratory Services Branch, Centre for Health Protection, Department of Health, The Government of the Hong Kong Special Administrative Region. In the second part of this study, we evaluated the SNP detection performance of four TIB MOLBIOL melting curve-based assays (1. Spike S371L/S373P, 2. Spike E484A, 3. Spike E484K and 4. Spike N501Y) in clinical samples obtained from hospitalized COVID-19 patients in Hong Kong. The SNP results were compared to whole genome sequences generated by Illumina platform.

Results

The VOC-Omicron detection limits of three commercial sample-to-answer assays were tested to be ≤ 2.35 Log10 dC/ml. The detection performances of the sample-to-answer platforms were comparable to the two tested conventional real-time RT-PCR assays. The test sensitivities of TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P assay and the Spike E484A assays were 100% and 96.6% respectively and the test specificities of both assays were 100%. An aberrant melting peak at Tm 42-44°C was observed when the specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay. Notably, the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike N501Y assay failed to detect the spike N501Y mutation of Omicron variant in the tested specimens.

Conclusions

The SARS-CoV-2 detection sensitivity of three commercial platforms, Roche cobas® 6800/8800, Roche cobas® Liat®, and Cepheid GeneXpert® systems were shown not to be impacted by the large number of mutations of VOC-Omicron. Also, the signature mutations i.e. Spike S371L/Spike S373P and Spike E484A in VOC-Omicron were correctly identified by the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P and VirSNiP SARS-CoV-2 Spike E484A assays. Unexpected findings including a shifted melting peak or absence of amplification curve/melting peak were observed when specimens with Omicron variant were tested with the TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K assay and Spike N501Y assay, suggesting a potential alert for Omicron variant, prior confirmation by whole genome sequencing.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用商业样品-应答实时RT-PCR平台和基于熔化曲线的SNP检测SARS-CoV-2 VOC-Omicron
目的世界卫生组织(WHO)于2011年11月26日将SARS-CoV-2谱系B.1.1.529指定为新的关注基因变异(VOC-Omicron)。实时逆转录聚合酶链反应(RT-PCR)、单核苷酸多态性(SNP)和全基因组测序(WGS)技术被广泛用于检测SARS-CoV-2及其变体。然而,商用实时RT-PCR平台和SARS-CoV-2刺突SNP检测的SARS-CoV-2 Omicron检测性能仍有待阐明。方法在本研究的第一部分,我们评估了三种商业化RT-PCR样品到答案平台(Roche cobas®6800/8800,Roche cobas®Liat®和Cepheid GeneXpert®系统)的VOC-Omicron检测性能。将检测性能与香港特别行政区政府卫生署卫生防护中心公共卫生化验服务科世卫组织COVID-19参考实验室的一种商用常规实时RT-PCR检测方法(TIB MOLBIOL LightMix模块化SARS和武汉冠状病毒e基因)和一种针对SARS-CoV-2 RNA依赖性RNA聚合酶(RdRP)基因的内部实时RT-PCR检测方法进行比较。在本研究的第二部分,我们评估了四种基于TIB MOLBIOL熔化曲线的检测方法的SNP检测性能(1)。S371L/S373P, 2。脉冲E484A, 3。Spike E484K和4。从香港住院的COVID-19患者的临床样本中提取的Spike N501Y)。将SNP结果与Illumina平台生成的全基因组序列进行比较。结果3种市售样品到应答法的VOC-Omicron检出限均≤2.35 Log10 dC/ml。样品到答案平台的检测性能与两种被测试的传统实时RT-PCR分析相当。TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P法和Spike E484A法的检测灵敏度分别为100%和96.6%,特异性均为100%。用TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K法检测带有Omicron变异的标本,在Tm 42-44°C时观察到异常熔化峰。值得注意的是,TIB MOLBIOL VirSNiP SARS-CoV-2 Spike N501Y实验未能检测到被试标本中Omicron变体的Spike N501Y突变。结论Roche cobas®6800/8800、Roche cobas®Liat®和Cepheid GeneXpert®3种商用平台的SARS-CoV-2检测灵敏度不受VOC-Omicron大量突变的影响。此外,通过TIB MOLBIOL VirSNiP SARS-CoV-2 Spike S371L/S373P和VirSNiP SARS-CoV-2 Spike E484A检测,VOC-Omicron中的特征突变Spike S371L/Spike S373P和Spike E484A均得到了正确的鉴定。当使用TIB MOLBIOL VirSNiP SARS-CoV-2 Spike E484K和Spike N501Y检测带有Omicron变体的标本时,观察到意想不到的发现,包括熔化峰移动或没有扩增曲线/熔化峰,提示可能存在Omicron变体的警报,事先通过全基因组测序进行确认。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of clinical virology plus
Journal of clinical virology plus Infectious Diseases
CiteScore
2.20
自引率
0.00%
发文量
0
审稿时长
66 days
期刊最新文献
Performance evaluation of the Qiagen BK virus ASR on the NeuMoDx system Environmental surveillance of SARS-CoV-2 for outbreak detection in hospital: A single centre prospective study Correlation of cytokine storm with ocular fundus abnormalities in critically ill patients with severe viral pneumonia A prospective study to evaluate the clinical specificity of the cobas® MPX test kit for screening for HIV RNA, HCV RNA, and HBV DNA in blood donation samples using the cobas® 6800 system in HBV endemic areas A rapid review of the epidemiology and combating strategies of hepatitis C virus infection in Ghana
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1