{"title":"Phosphorus removal and recovery from anaerobic bioreactor effluent using a batch electrocoagulation process","authors":"G. P. Bhoi, Kripa S. Singh, Dennis A. Connor","doi":"10.2166/wqrj.2023.111","DOIUrl":null,"url":null,"abstract":"\n \n A batch monopolar electrocoagulation system was developed and studied for the removal of phosphorus from anaerobic bioreactor effluent using iron as an electrode material. The study focused on the optimization of the independent variables, such as initial pH, retention time (RT), current density (CD) and inter-electrode distance (IED) using the response surface methodology (RSM) to maximize the removal of total phosphorus (TP). A quadratic model was fitted to the experimental data for TP removal. The optimal parameters were found to be pH of 6.75, RT of 11.06 min, CD of 300 A/m2, and inter-electrode distance of 1.5 cm resulting in 98.05% TP removal and energy consumption of 1.28 kWh/m3. A kinetic study for TP removal revealed that at optimal conditions, removal followed first-order kinetics (K = 0.185 m/min). Phosphorus was recovered from the post-precipitated sludge through combustion at 900 °C followed by acid leaching with sulfuric acid. Acid leaching tests were carried out with sulfuric acid for the post-precipitated sludge obtained at the optimum conditions. It resulted in around 91% of phosphorus recovery at a liquid-to-solid ratio of 100 mL/g.","PeriodicalId":23720,"journal":{"name":"Water Quality Research Journal","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2023-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Quality Research Journal","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wqrj.2023.111","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"WATER RESOURCES","Score":null,"Total":0}
引用次数: 0

Abstract

A batch monopolar electrocoagulation system was developed and studied for the removal of phosphorus from anaerobic bioreactor effluent using iron as an electrode material. The study focused on the optimization of the independent variables, such as initial pH, retention time (RT), current density (CD) and inter-electrode distance (IED) using the response surface methodology (RSM) to maximize the removal of total phosphorus (TP). A quadratic model was fitted to the experimental data for TP removal. The optimal parameters were found to be pH of 6.75, RT of 11.06 min, CD of 300 A/m2, and inter-electrode distance of 1.5 cm resulting in 98.05% TP removal and energy consumption of 1.28 kWh/m3. A kinetic study for TP removal revealed that at optimal conditions, removal followed first-order kinetics (K = 0.185 m/min). Phosphorus was recovered from the post-precipitated sludge through combustion at 900 °C followed by acid leaching with sulfuric acid. Acid leaching tests were carried out with sulfuric acid for the post-precipitated sludge obtained at the optimum conditions. It resulted in around 91% of phosphorus recovery at a liquid-to-solid ratio of 100 mL/g.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
间歇式电絮凝法去除厌氧生物反应器出水中的磷
以铁为电极材料,开发并研究了一种间歇式单极电絮凝系统对厌氧生物反应器出水中磷的去除。本研究的重点是使用响应面法(RSM)优化自变量,如初始pH、保留时间(RT)、电流密度(CD)和电极间距离(IED),以最大限度地去除总磷(TP)。将二次模型拟合到TP去除的实验数据中。最佳参数为pH为6.75,RT为11.06min,CD为300A/m2,电极间距离为1.5cm,TP去除率为98.05%,能耗为1.28kWh/m3。TP去除的动力学研究表明,在最佳条件下,去除遵循一级动力学(K=0.185 m/min)。通过在900°C下燃烧,然后用硫酸进行酸浸,从后沉淀污泥中回收磷。对在最佳条件下获得的后沉淀污泥进行了硫酸酸浸试验。在100mL/g的液固比下,它导致约91%的磷回收率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.50
自引率
8.70%
发文量
0
期刊最新文献
Development and evaluation of filter for canal water potability Phosphorus removal and recovery from anaerobic bioreactor effluent using a batch electrocoagulation process A Fuzzy Inference System for enhanced groundwater quality assessment and index determination The risk of bacterial virulence in the face of concentrated river pollution Efficient removal of perfluorinated compounds with the polyamide nanofiltration membrane and membrane fouling resistance analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1