Performance evaluation of the bio-rad BioPlex 2200 multiplex system in the detection of measles, mumps, rubella, and varicella-zoster antibodies

IF 1.6 Q4 INFECTIOUS DISEASES Journal of clinical virology plus Pub Date : 2023-02-01 DOI:10.1016/j.jcvp.2022.100131
Matthew A. Lafrenière , Eley Badr , John Beattie , Joseph Macri , Waliul I. Khan
{"title":"Performance evaluation of the bio-rad BioPlex 2200 multiplex system in the detection of measles, mumps, rubella, and varicella-zoster antibodies","authors":"Matthew A. Lafrenière ,&nbsp;Eley Badr ,&nbsp;John Beattie ,&nbsp;Joseph Macri ,&nbsp;Waliul I. Khan","doi":"10.1016/j.jcvp.2022.100131","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Measles, mumps, rubella, and varicella-zoster (MMRV) immunity testing is important in occupational screening of healthcare workers and at-risk populations.</p></div><div><h3>Objectives</h3><p>The goal of this study was to compare the performance of the Bio-Rad BioPlex 2200 MMRV multiplex fluorescence immunoassay (MFI) against two enzyme immunoassay (EIA) methods: the Bio-Rad Evolis Twin Plus measles, mumps, and varicella-zoster (MMV) IgG assay and the Abbott Architect Rubella IgG assay.</p></div><div><h3>Study Design</h3><p>Clinically uncharacterized serum specimens were obtained and analyzed using the Bio-Rad BioPlex assay and compared against the EIA methods.</p></div><div><h3>Results</h3><p>The Bio-Rad BioPlex demonstrated total agreement of 85.5% (95% confidence interval (CI), 78.0 to 90.7%), 92.7% (95% confidence interval (CI), 86.7 to 96.1%), 92.4% (95% confidence interval (CI), 86.9 to 95.7%), and 98.8% (95% confidence interval (CI), 93.7 to 99.8%) for measles, mumps, varicella-zoster, and rubella, respectively, against the current EIA methods. Furthermore, precision testing agreed with the manufacturer's package insert in 10 of 13 pooled samples.</p></div><div><h3>Conclusion</h3><p>These data indicate that the Bio-Rad BioPlex has comparable performance to the EIA methods.</p></div>","PeriodicalId":73673,"journal":{"name":"Journal of clinical virology plus","volume":"3 1","pages":"Article 100131"},"PeriodicalIF":1.6000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical virology plus","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667038022000709","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Measles, mumps, rubella, and varicella-zoster (MMRV) immunity testing is important in occupational screening of healthcare workers and at-risk populations.

Objectives

The goal of this study was to compare the performance of the Bio-Rad BioPlex 2200 MMRV multiplex fluorescence immunoassay (MFI) against two enzyme immunoassay (EIA) methods: the Bio-Rad Evolis Twin Plus measles, mumps, and varicella-zoster (MMV) IgG assay and the Abbott Architect Rubella IgG assay.

Study Design

Clinically uncharacterized serum specimens were obtained and analyzed using the Bio-Rad BioPlex assay and compared against the EIA methods.

Results

The Bio-Rad BioPlex demonstrated total agreement of 85.5% (95% confidence interval (CI), 78.0 to 90.7%), 92.7% (95% confidence interval (CI), 86.7 to 96.1%), 92.4% (95% confidence interval (CI), 86.9 to 95.7%), and 98.8% (95% confidence interval (CI), 93.7 to 99.8%) for measles, mumps, varicella-zoster, and rubella, respectively, against the current EIA methods. Furthermore, precision testing agreed with the manufacturer's package insert in 10 of 13 pooled samples.

Conclusion

These data indicate that the Bio-Rad BioPlex has comparable performance to the EIA methods.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bio-Rad BioPlex 2200复合系统检测麻疹、腮腺炎、风疹和水痘带状疱疹抗体的性能评价
背景麻疹、腮腺炎、风疹和水痘-带状疱疹(MMRV)免疫测试在医护人员和高危人群的职业筛查中很重要。目的本研究的目的是比较Bio-Rad BioPlex 2200 MMRV多重荧光免疫测定(MFI)与两种酶免疫测定(EIA)方法的性能:Bio-Rad Evolis Twin Plus麻疹、腮腺炎和水痘带状疱疹(MMV)IgG测定和Abbott Architect Rubella IgG测定。研究设计使用Bio-Rad-BioPlex测定法获得并分析临床上未表征的血清样本,并与EIA方法进行比较。结果Bio-Rad-BioPlex对麻疹、腮腺炎、水痘-带状疱疹和风疹的总符合率分别为85.5%(95%置信区间,78.0至90.7%)、92.7%(95%可信区间,86.7至96.1%)、92.4%(95%置信间隔,86.9至95.7%)和98.8%(95%置信程度,93.7至99.8%)。此外,在13个合并样本中的10个样本中,精密度测试与制造商的包装插入物一致。结论这些数据表明,Bio-Rad-BioPlex具有与EIA方法相当的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of clinical virology plus
Journal of clinical virology plus Infectious Diseases
CiteScore
2.20
自引率
0.00%
发文量
0
审稿时长
66 days
期刊最新文献
Performance evaluation of the Qiagen BK virus ASR on the NeuMoDx system Environmental surveillance of SARS-CoV-2 for outbreak detection in hospital: A single centre prospective study Correlation of cytokine storm with ocular fundus abnormalities in critically ill patients with severe viral pneumonia A prospective study to evaluate the clinical specificity of the cobas® MPX test kit for screening for HIV RNA, HCV RNA, and HBV DNA in blood donation samples using the cobas® 6800 system in HBV endemic areas A rapid review of the epidemiology and combating strategies of hepatitis C virus infection in Ghana
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1