Development and validation of a novel bioanalytical method for the simultaneous determination of glecaprevir and pibrentasvir in human plasma using reversed-phase high-performance liquid chromatography

IF 0.7 Q4 PHARMACOLOGY & PHARMACY Egyptian Pharmaceutical Journal Pub Date : 2022-10-01 DOI:10.4103/epj.epj_47_22
Bonagiri Pavani, Malothu Narender, D. Prasanth, C. Guntupalli
{"title":"Development and validation of a novel bioanalytical method for the simultaneous determination of glecaprevir and pibrentasvir in human plasma using reversed-phase high-performance liquid chromatography","authors":"Bonagiri Pavani, Malothu Narender, D. Prasanth, C. Guntupalli","doi":"10.4103/epj.epj_47_22","DOIUrl":null,"url":null,"abstract":"Background and objective For the simultaneous determination of glecaprevir (GPR) and pibrentasvir (PTR) in human plasma, a novel, accurate, and selective reversed-phase high-performance liquid chromatography method was developed and validated. Materials and methods Owing to structural resemblance, bictegravir was selected as an internal standard. Anticoagulant used was K2-EDTA. The GPR-PTR was the first of its kind approved drug by FDA for the treatment of chronic hepatitis C. Precipitation technique with acetonitrile was employed for the extraction of analyte from human plasma. Kromasil C18 column (5 μ, 150×4.6 mm) with an isocratic mobile phase of 0.1% orthophosphoric acid buffer pH 4.3, adjusted with dilute hydrochloric acid: acetonitrile in the ratio of 70 : 30 v/v, was used for the resolution. At a flow rate of 1 ml/min, the mobile phase was pumped. Using a photodiode array detector, effluents were monitored at 250 nm. Results Over concentration ranges of 5–200 μg/ml and 6.650–266.000 μg/ml, the method was found to be linear for GPR and PTR, respectively, in human plasma, with the precision and accuracy ranging from 0.76 to 9.05% and 90.55 to 98.98% for GPR respectively, whereas for PTR ranged from 0.74 to 9.52% and 91.56 to 105.61%, respectively. Conclusion The stability of the analyte was evaluated in plasma under different stress conditions.","PeriodicalId":11568,"journal":{"name":"Egyptian Pharmaceutical Journal","volume":"21 1","pages":"424 - 431"},"PeriodicalIF":0.7000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Pharmaceutical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/epj.epj_47_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 1

Abstract

Background and objective For the simultaneous determination of glecaprevir (GPR) and pibrentasvir (PTR) in human plasma, a novel, accurate, and selective reversed-phase high-performance liquid chromatography method was developed and validated. Materials and methods Owing to structural resemblance, bictegravir was selected as an internal standard. Anticoagulant used was K2-EDTA. The GPR-PTR was the first of its kind approved drug by FDA for the treatment of chronic hepatitis C. Precipitation technique with acetonitrile was employed for the extraction of analyte from human plasma. Kromasil C18 column (5 μ, 150×4.6 mm) with an isocratic mobile phase of 0.1% orthophosphoric acid buffer pH 4.3, adjusted with dilute hydrochloric acid: acetonitrile in the ratio of 70 : 30 v/v, was used for the resolution. At a flow rate of 1 ml/min, the mobile phase was pumped. Using a photodiode array detector, effluents were monitored at 250 nm. Results Over concentration ranges of 5–200 μg/ml and 6.650–266.000 μg/ml, the method was found to be linear for GPR and PTR, respectively, in human plasma, with the precision and accuracy ranging from 0.76 to 9.05% and 90.55 to 98.98% for GPR respectively, whereas for PTR ranged from 0.74 to 9.52% and 91.56 to 105.61%, respectively. Conclusion The stability of the analyte was evaluated in plasma under different stress conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
反相高效液相色谱法同时测定人血浆中glecaprevir和pibrentasvir的新方法的建立和验证
背景与目的为同时测定人血浆中glecaprevir (GPR)和pibrentasvir (PTR),建立了一种新的、准确的、选择性的反相高效液相色谱法。材料与方法由于结构相似,选择比替他韦作为内标。使用的抗凝剂为K2-EDTA。GPR-PTR是首个获FDA批准用于治疗慢性丙型肝炎的药物。采用乙腈沉淀技术提取人血浆分析物。采用Kromasil C18色谱柱(5 μ, 150×4.6 mm),流动相为0.1%正磷酸缓冲液pH 4.3,用稀盐酸:乙腈以70:30 v/v的比例调节。以1 ml/min的流速泵送流动相。使用光电二极管阵列检测器,在250 nm处监测流出物。结果在5 ~ 200 μg/ml和6.650 ~ 266.000 μg/ml浓度范围内,该方法对人血浆中GPR和PTR均具有良好的线性关系,GPR的精密度和准确度分别为0.76 ~ 9.05%和90.55 ~ 98.98%,PTR的精密度和准确度分别为0.74 ~ 9.52%和91.56 ~ 105.61%。结论在不同应激条件下,评价了该分析物在血浆中的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Egyptian Pharmaceutical Journal
Egyptian Pharmaceutical Journal PHARMACOLOGY & PHARMACY-
CiteScore
1.10
自引率
0.00%
发文量
37
期刊最新文献
Therapeutic effects of the Egyptian horned viper LAAO against hepatocellular carcinoma induced in rats Effect of different carbon sources on callus formation, pigment accumulation, and antiviral activity in cell cultures of Euphorbia milii Anticoagulant and antibacterial activities of polysaccharides fraction from Nostoc muscorum and Arthrospira platensis cultivated under abiotic stress conditions Stem cell mechanism of action in neuroplasticity after stroke Metallo β- lactamase producing pseudomonas aeruginosa: a worrisome situation to handle
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1