Feasibility of control of particle assembly by dielectrophoresis in liquid-cell transmission electron microscopy

IF 1.5 4区 工程技术 Q3 MICROSCOPY Microscopy Pub Date : 2022-04-23 DOI:10.1093/jmicro/dfac021
T. Yamazaki, Hiromasa Niinomi, Y. Kimura
{"title":"Feasibility of control of particle assembly by dielectrophoresis in liquid-cell transmission electron microscopy","authors":"T. Yamazaki, Hiromasa Niinomi, Y. Kimura","doi":"10.1093/jmicro/dfac021","DOIUrl":null,"url":null,"abstract":"Abstract Liquid-cell transmission electron microscopy (LC-TEM) is a useful technique for observing phenomena in liquid samples with spatial and temporal resolutions similar to those of conventional transmission electron microscopy (TEM). This method is therefore expected to permit the visualization of phenomena previously inaccessible to conventional optical microscopy. However, dynamic processes such as nucleation are difficult to observe by this method because of difficulties in controlling the condition of the sample liquid in the observation area. To approach this problem, we focused on dielectrophoresis, in which electrodes are used to assemble particles, and we investigated the phenomena that occurred when an alternating-current signal was applied to an electrode in an existing liquid cell by using a phase-contrast optical microscope (PCM) and TEM. In PCM, we observed that colloidal particles in a solution were attracted to the electrodes to form assemblies, that the particles aligned along the electric field to form pearl chains and that the pearl chains accumulated to form colloidal crystals. However, these phenomena were not observed in the TEM study because of differences in the design of the relevant holders. The results of our study imply that the particle assembly by using dielectrophoretic forces in LC-TEM should be possible, but further studies, including electric device development, will be required to realize this in practice.","PeriodicalId":48655,"journal":{"name":"Microscopy","volume":"71 1","pages":"231 - 237"},"PeriodicalIF":1.5000,"publicationDate":"2022-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1093/jmicro/dfac021","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MICROSCOPY","Score":null,"Total":0}
引用次数: 2

Abstract

Abstract Liquid-cell transmission electron microscopy (LC-TEM) is a useful technique for observing phenomena in liquid samples with spatial and temporal resolutions similar to those of conventional transmission electron microscopy (TEM). This method is therefore expected to permit the visualization of phenomena previously inaccessible to conventional optical microscopy. However, dynamic processes such as nucleation are difficult to observe by this method because of difficulties in controlling the condition of the sample liquid in the observation area. To approach this problem, we focused on dielectrophoresis, in which electrodes are used to assemble particles, and we investigated the phenomena that occurred when an alternating-current signal was applied to an electrode in an existing liquid cell by using a phase-contrast optical microscope (PCM) and TEM. In PCM, we observed that colloidal particles in a solution were attracted to the electrodes to form assemblies, that the particles aligned along the electric field to form pearl chains and that the pearl chains accumulated to form colloidal crystals. However, these phenomena were not observed in the TEM study because of differences in the design of the relevant holders. The results of our study imply that the particle assembly by using dielectrophoretic forces in LC-TEM should be possible, but further studies, including electric device development, will be required to realize this in practice.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
液体细胞透射电子显微镜中介质电泳控制粒子组装的可行性
液池透射电子显微镜(LC-TEM)是一种有效的观察液体样品现象的技术,具有与传统透射电子显微镜(TEM)相似的空间和时间分辨率。因此,这种方法有望使以前传统光学显微镜无法实现的现象可视化。然而,由于难以控制观察区域内样品液体的状态,这种方法难以观察到成核等动态过程。为了解决这一问题,我们重点研究了用电极组装粒子的介电电泳,并利用相对比光学显微镜(PCM)和透射电镜(TEM)研究了将交流电流信号施加到现有液体电池中的电极上时发生的现象。在PCM中,我们观察到溶液中的胶体颗粒被吸引到电极上形成组件,颗粒沿着电场排列形成珍珠链,珍珠链积累形成胶体晶体。然而,由于相关支架设计的差异,在TEM研究中没有观察到这些现象。我们的研究结果表明,在LC-TEM中利用介电泳力进行粒子组装是可能的,但需要进一步的研究,包括电气设备的开发,才能在实践中实现这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microscopy
Microscopy Physics and Astronomy-Instrumentation
CiteScore
3.30
自引率
11.10%
发文量
76
期刊介绍: Microscopy, previously Journal of Electron Microscopy, promotes research combined with any type of microscopy techniques, applied in life and material sciences. Microscopy is the official journal of the Japanese Society of Microscopy.
期刊最新文献
In This Issue Real-time scanning electron microscopy of unfixed tissue in the solution using a deformable and electron-transmissive film Atomic-Resolution STEM Image Denoising by Total Variation Regularization. Super-Resolution Reconstruction Based on BM3D and Compressed Sensing. Reliable Electrochemical Setup for in situ Observations with an Atmospheric SEM.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1