Improvement in Bioactivity Properties of Hydroxyapatite Coated Ti-6Al-4V ELI with Addition of Zirconium Oxide for Orthopaedic Implant

IF 0.5 Q4 ENGINEERING, BIOMEDICAL Journal of Biomimetics, Biomaterials and Biomedical Engineering Pub Date : 2023-02-14 DOI:10.4028/p-05a039
S. Ardhy, Gunawarman, J. Affi, Y. Yetri
{"title":"Improvement in Bioactivity Properties of Hydroxyapatite Coated Ti-6Al-4V ELI with Addition of Zirconium Oxide for Orthopaedic Implant","authors":"S. Ardhy, Gunawarman, J. Affi, Y. Yetri","doi":"10.4028/p-05a039","DOIUrl":null,"url":null,"abstract":"One of factor causing the failure of Ti-6Al-4V Extra Low Interstitial (ELI)-based material implants, does not have bioactive properties in the implantation process, thus not supporting the osseointegration process in the body. For this reason, coating with hydroxyapatite (HA) suspension is necessary. This research used the dip-coating method and added Zirconium Oxide (ZrO2) into nanosized commercial HA to be suspensions (17%wt and 20%wt) to strengthen the adhesion of the coating. The specimens were heated at 800, 900, and 950°C to densify the layers. Bioactivity increased along with the increasing calcium/phosphate (Ca/P) ratio of the HA layers in the test specimens. The specimens were immersed in Simulated Body Fluid (SBF), namely Hank’s Solution, for 1, 2, 3, and 4 weeks. ZrO2 added to the HA suspensions of Ti-6Al-4V ELI can increase the Ca/P ratio from 1.51 in the first immersion week to 1.62 in the fourth. The bioactivity level is also proven by the accumulation of calcium and phosphate on the surface of the coating. The Ca/P value close to the Ca/P ratio of HA of 1.67 is good for improving the osseointegration process in the body.","PeriodicalId":15161,"journal":{"name":"Journal of Biomimetics, Biomaterials and Biomedical Engineering","volume":"59 1","pages":"81 - 89"},"PeriodicalIF":0.5000,"publicationDate":"2023-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomimetics, Biomaterials and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-05a039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

One of factor causing the failure of Ti-6Al-4V Extra Low Interstitial (ELI)-based material implants, does not have bioactive properties in the implantation process, thus not supporting the osseointegration process in the body. For this reason, coating with hydroxyapatite (HA) suspension is necessary. This research used the dip-coating method and added Zirconium Oxide (ZrO2) into nanosized commercial HA to be suspensions (17%wt and 20%wt) to strengthen the adhesion of the coating. The specimens were heated at 800, 900, and 950°C to densify the layers. Bioactivity increased along with the increasing calcium/phosphate (Ca/P) ratio of the HA layers in the test specimens. The specimens were immersed in Simulated Body Fluid (SBF), namely Hank’s Solution, for 1, 2, 3, and 4 weeks. ZrO2 added to the HA suspensions of Ti-6Al-4V ELI can increase the Ca/P ratio from 1.51 in the first immersion week to 1.62 in the fourth. The bioactivity level is also proven by the accumulation of calcium and phosphate on the surface of the coating. The Ca/P value close to the Ca/P ratio of HA of 1.67 is good for improving the osseointegration process in the body.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
氧化锆对羟基磷灰石包覆Ti-6Al-4V ELI生物活性的改善
导致Ti-6Al-4V超低间质(ELI)材料植入失败的因素之一是在植入过程中不具有生物活性,因此不能支持体内的骨整合过程。因此,有必要用羟基磷灰石(HA)悬浮液涂覆。本研究采用浸涂法,将氧化锆(ZrO2)加入到纳米级商用透明质酸(17%wt和20%wt)的悬浮液中,以增强涂层的附着力。试样分别在800、900和950℃加热以使层致密化。生物活性随着试验样品中HA层钙/磷酸盐(Ca/P)比的增加而增加。将标本浸泡在模拟体液(SBF)中,即Hank’s Solution中1、2、3、4周。在Ti-6Al-4V ELI的HA悬液中加入ZrO2可以使Ca/P比值从第一周的1.51提高到第四周的1.62。生物活性水平也被证明是由钙和磷酸盐在涂层表面的积累。Ca/P值接近HA的Ca/P值1.67,有利于促进体内骨整合过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.40
自引率
14.30%
发文量
73
期刊最新文献
Multiple Channels Model Based on Mel Spectrogram for Classifying Abnormalities in Lung Sound Effect of Plant Oil Derived Bio-Resin and Curing Temperature on Static and Dynamic Mechanical Properties of Epoxy Network Active Rehabilitation Gloves Based on Brain-Computer Interfaces and Deep Learning <i>In Vitro</i> Study: Bioactivity, Biocompatibility and Antibacterial Behavior for Polyetheretherketone Composites Synthesis of Colloidal Silver Nanoparticles Using Alginate as Reducing and Stabilizing Agents and its Application as Antibacterial Material
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1