{"title":"A portable multispectral vein imaging system","authors":"H. Ozkan, Muberra Aydin, O. Ozcan, Ummuhan Zengin","doi":"10.2478/jee-2023-0008","DOIUrl":null,"url":null,"abstract":"Abstract Phlebotomy may cause unnecessary injuries to a patient whose veins are not easily visible to a healthcare professional. To mitigate this problem we designed a new system to image subcutaneous veins. Multispectral images were obtained using a microprocessor, an IR (infrared) camera, different wavelengths of NIR (near-infrared) sources, and an IR band-pass filter. Raw vein images were enhanced, colored, and displayed on a monitor using an easy-to-use interface. The mean dice similarity index (DSI) between the vein border specified by a doctor on the raw images manually and the automated segmented by the proposed system is determined as 0.92 ± 2.1 for 20 subjects. Also, the average peak signal-to-noise ratio (PSNR) obtained a high value of 68.37 ± 1.56 from the enhanced image. Phlebotomists can easily observe the subcutaneous veins in real-time with the three different options using the proposed device. As a result, this study advances the vein imaging field which has the potential to reduce injury to the patient during venipuncture.","PeriodicalId":15661,"journal":{"name":"Journal of Electrical Engineering-elektrotechnicky Casopis","volume":"74 1","pages":"64 - 69"},"PeriodicalIF":1.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Engineering-elektrotechnicky Casopis","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/jee-2023-0008","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Phlebotomy may cause unnecessary injuries to a patient whose veins are not easily visible to a healthcare professional. To mitigate this problem we designed a new system to image subcutaneous veins. Multispectral images were obtained using a microprocessor, an IR (infrared) camera, different wavelengths of NIR (near-infrared) sources, and an IR band-pass filter. Raw vein images were enhanced, colored, and displayed on a monitor using an easy-to-use interface. The mean dice similarity index (DSI) between the vein border specified by a doctor on the raw images manually and the automated segmented by the proposed system is determined as 0.92 ± 2.1 for 20 subjects. Also, the average peak signal-to-noise ratio (PSNR) obtained a high value of 68.37 ± 1.56 from the enhanced image. Phlebotomists can easily observe the subcutaneous veins in real-time with the three different options using the proposed device. As a result, this study advances the vein imaging field which has the potential to reduce injury to the patient during venipuncture.
期刊介绍:
The joint publication of the Slovak University of Technology, Faculty of Electrical Engineering and Information Technology, and of the Slovak Academy of Sciences, Institute of Electrical Engineering, is a wide-scope journal published bimonthly and comprising.
-Automation and Control-
Computer Engineering-
Electronics and Microelectronics-
Electro-physics and Electromagnetism-
Material Science-
Measurement and Metrology-
Power Engineering and Energy Conversion-
Signal Processing and Telecommunications