{"title":"Effect of photo-polymerization mode on the degree of conversion of resin cement under different ceramic materials.","authors":"K. Ebeid, A. Sabet, Nancy Rafla, N. Al-Haj Husain, M. Özcan","doi":"10.23736/S0026-4970.20.04354-X","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nThis study evaluated the effect of different polymerization modes and duration on the degree of conversion (DC) of resin cement under different types of ceramics.\n\n\nMETHODS\nCeramic materials were divided into 3 groups (n=60): Group 1; CERASMART, Group 2; Vita Enamic and Group 3; Vita MARK II. Each group was then divided into three subgroups (n=20) according to the polymerization mode (A; low-intensity, B; high-intensity, and C; soft-start). Subgroups were then divided into two further groups according to the polymerization time (I; 10 s and II; 20 s). DC of light-cured resin cement beneath different kinds of ceramics was tested using FTIR spectroscopy. Results were compared to a control group cured without overlying ceramic.\n\n\nRESULTS\nWhile the type of ceramic and mode of polymerization showed a significant effect on the DC of resin cement, polymerization duration did not. Vita Mark II group showed significantly the highest DC of resin cement, followed by Vita Enamic and Cerasmart. High and low intensity polymerization modes did not show significant difference but both showed significantly lower DC when compared to soft start mode.\n\n\nCONCLUSIONS\nType of ceramic and polymerization mode showed a direct effect on the DC of resin cement.","PeriodicalId":18742,"journal":{"name":"Minerva stomatologica","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva stomatologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0026-4970.20.04354-X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

BACKGROUND This study evaluated the effect of different polymerization modes and duration on the degree of conversion (DC) of resin cement under different types of ceramics. METHODS Ceramic materials were divided into 3 groups (n=60): Group 1; CERASMART, Group 2; Vita Enamic and Group 3; Vita MARK II. Each group was then divided into three subgroups (n=20) according to the polymerization mode (A; low-intensity, B; high-intensity, and C; soft-start). Subgroups were then divided into two further groups according to the polymerization time (I; 10 s and II; 20 s). DC of light-cured resin cement beneath different kinds of ceramics was tested using FTIR spectroscopy. Results were compared to a control group cured without overlying ceramic. RESULTS While the type of ceramic and mode of polymerization showed a significant effect on the DC of resin cement, polymerization duration did not. Vita Mark II group showed significantly the highest DC of resin cement, followed by Vita Enamic and Cerasmart. High and low intensity polymerization modes did not show significant difference but both showed significantly lower DC when compared to soft start mode. CONCLUSIONS Type of ceramic and polymerization mode showed a direct effect on the DC of resin cement.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同陶瓷材料下光聚合方式对树脂水泥转化率的影响。
背景本研究评估了不同聚合方式和聚合时间对不同类型陶瓷下树脂水泥转化率的影响。方法将陶瓷材料分为3组(n=60):第一组;CERASMART,第2组;Vita珐琅质和第3组;Vita MARK II。然后,根据聚合模式将每组分为三个亚组(n=20)(A;低强度、B;高强度和C;软启动)。然后根据聚合时间(I;10s和II;20s)将亚组进一步分为两组。用红外光谱法测试了光固化树脂水泥在不同陶瓷下的直流电性能。将结果与未覆盖陶瓷的对照组进行比较。结果陶瓷类型和聚合方式对树脂水泥的直流电性能有显著影响,但聚合时间不影响。Vita Mark II组树脂水泥的DC最高,其次是Vita Enamic和Cerasmart。与软启动模式相比,高强度和低强度聚合模式没有显示出显著差异,但两者都显示出显著较低的DC。结论陶瓷类型和聚合方式对树脂水泥的直流电性能有直接影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Minerva stomatologica
Minerva stomatologica DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.50
自引率
0.00%
发文量
0
期刊介绍: The journal Minerva Stomatologica publishes scientific papers on dentistry and maxillo-facial surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor. Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.
期刊最新文献
WITHDRAWN: Extranodal B-cell marginal zone lymphoma arising in the context of a lympho-epithelial cyst of the parotid gland in a patient with clonal B-cell lymphocytosis: report of the first case. Sexual dimorphism and infra orbital foramen: a computerized tomography-Scan study in a coorte of Senegalese population. Correlation between Vista Cam, ICDAS-II, X-ray bitewings and cavity extent after lesion excavation: an in-vivo pilot study. Assessment of the configuration of the mandibular canal using cone beam computed tomography. Direct oral anticoagulants in oral surgery: a prospective cohort.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1