Effect on the pull out and the bond strength of concrete by different surface treatment of steel reinforcement bars

IF 0.1 Q4 ENGINEERING, CHEMICAL Journal of the Pakistan Institute of Chemical Engineers Pub Date : 2019-08-21 DOI:10.54693/piche.04712
A. Saleem, A. Farooq, R. Ahmad
{"title":"Effect on the pull out and the bond strength of concrete by different surface treatment of steel reinforcement bars","authors":"A. Saleem, A. Farooq, R. Ahmad","doi":"10.54693/piche.04712","DOIUrl":null,"url":null,"abstract":"In present research, it is aimed to study the effect of different interface of steel reinforcement bars on the pull out and bond strength of the concrete. The concrete possess a good compressional strength but relatively low pull out strength. So to enhance its pull out strength different reinforcements like steel bars, wires etc. are introduced in the concrete. The introduced steel bars give good pull out properties to concrete but also affected in corrosive environment. Different interface is made to protect these bars from corrosion by applying different treatment on the interface between surrounding concrete and steel bars which affects the bond strength between concrete and the re-bar. Reinforced bars are surface treated with emulsion paint, polyester resin, alkali and lubricating oil. Ravi and Chenab sand are used to produce two different concrete, having the compressional strength of 24.37 MPa and 19.25 MPa respectively. Pull out testing to find out the pullout strength which is further used to calculate the bond strengths. The results shows that both types of concrete specimens possess the maximum pull out and bond strength for untreated reinforcement bars The specimens with painted reinforcement bars has the minimum pull out and bond strength among all the specimens. The ravi sand has pull out strength of 5kN and 3kN for untreated and paint surface treated respectively while chenab sand has pull out strength of 7.5kN and 2.5kN for untreated and paint surface treated respectively.","PeriodicalId":17383,"journal":{"name":"Journal of the Pakistan Institute of Chemical Engineers","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2019-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Pakistan Institute of Chemical Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.54693/piche.04712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 1

Abstract

In present research, it is aimed to study the effect of different interface of steel reinforcement bars on the pull out and bond strength of the concrete. The concrete possess a good compressional strength but relatively low pull out strength. So to enhance its pull out strength different reinforcements like steel bars, wires etc. are introduced in the concrete. The introduced steel bars give good pull out properties to concrete but also affected in corrosive environment. Different interface is made to protect these bars from corrosion by applying different treatment on the interface between surrounding concrete and steel bars which affects the bond strength between concrete and the re-bar. Reinforced bars are surface treated with emulsion paint, polyester resin, alkali and lubricating oil. Ravi and Chenab sand are used to produce two different concrete, having the compressional strength of 24.37 MPa and 19.25 MPa respectively. Pull out testing to find out the pullout strength which is further used to calculate the bond strengths. The results shows that both types of concrete specimens possess the maximum pull out and bond strength for untreated reinforcement bars The specimens with painted reinforcement bars has the minimum pull out and bond strength among all the specimens. The ravi sand has pull out strength of 5kN and 3kN for untreated and paint surface treated respectively while chenab sand has pull out strength of 7.5kN and 2.5kN for untreated and paint surface treated respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
钢筋表面处理对混凝土拔出和粘结强度的影响
本研究旨在研究不同钢筋界面对混凝土拉拔强度和粘结强度的影响。混凝土具有较好的抗压强度,但抗拉强度较低。为了提高混凝土的抗拔强度,在混凝土中引入了钢筋、钢丝等不同的增强材料。引入的钢筋对混凝土具有良好的拉拔性能,但在腐蚀环境中也会受到影响。通过对周围混凝土和钢筋之间的界面进行不同的处理,形成不同的界面来保护这些钢筋免受腐蚀,从而影响混凝土与钢筋之间的结合强度。钢筋表面用乳胶漆、聚酯树脂、碱和润滑油处理。采用Ravi砂和Chenab砂配制两种不同的混凝土,抗压强度分别为24.37 MPa和19.25 MPa。拉出试验,求出拉出强度,并以此计算粘结强度。结果表明:未加筋的两种混凝土试件的拉拔强度和粘结强度均最大,加筋的两种混凝土试件的拉拔强度和粘结强度最小;ravi砂在未处理和油漆表面处理时的抗拔强度分别为5kN和3kN, chenab砂在未处理和油漆表面处理时的抗拔强度分别为7.5kN和2.5kN。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
13
期刊最新文献
Effective removal of Rhodamine 6G (Basic Red-1) reactive dye using waxy corn starch in waste water of textile industry An alternate acid cleaning process for the regeneration of waste engine oil and a proposed procedure for the disposal of produced sludge Modelling of the isothermal vapor-liquid equilibrium of alternative refrigerants: Determination of phase diagrams (high-pressure/low-pressure) and optimized binary interaction parameters Evaluation of energy sources from municipal solid waste of Gujranwala city in Pakistan A study on electrical resistivity characteristics of Pakistani coal char for earth grounding system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1