{"title":"Traffic noise attenuation solutions for naturally ventilated classrooms in South Africa","authors":"Coralie van Reenen, Chrisna du Plessis","doi":"10.1177/1351010X211064000","DOIUrl":null,"url":null,"abstract":"Traffic noise transmission through the open windows of naturally-ventilated classrooms can reduce speech intelligibility and can negatively impact academic performance. The findings of a numerical study are presented. Software was used to assess effective noise attenuation solutions for naturally-ventilated classrooms exposed to traffic noise. A typical situation in urban schools in Gauteng, South Africa, is considered in which classrooms are ventilated by large open windows in accordance with national building regulations and norms and standards for school design. The aim of the study was to establish a heuristic framework for early design decisions regarding how far from the road a classroom building should be set, and the effective height and position of a solid noise barrier to ensure a suitable ambient noise level inside a classroom with open windows. Efficacy was measured with reference to an indoor ambient sound level of 40 dBA. The findings show that with the insertion of barriers, the required ambient level was achieved for a classroom at least 68 m from the road, if the barrier is at least 3.5 m high. However, it was found that a significant insertion loss (>6 dB) and an improved signal to noise ratio could be achieved for classrooms as close as 17 m from the road with a barrier of at least 2 m high. Though not broadly generalizable, the findings provide a heuristic guide applicable for designing new schools or selecting attenuation interventions in existing city schools that are similar to those used in the study.","PeriodicalId":51841,"journal":{"name":"BUILDING ACOUSTICS","volume":"29 1","pages":"63 - 84"},"PeriodicalIF":1.4000,"publicationDate":"2021-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BUILDING ACOUSTICS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1351010X211064000","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0

Abstract

Traffic noise transmission through the open windows of naturally-ventilated classrooms can reduce speech intelligibility and can negatively impact academic performance. The findings of a numerical study are presented. Software was used to assess effective noise attenuation solutions for naturally-ventilated classrooms exposed to traffic noise. A typical situation in urban schools in Gauteng, South Africa, is considered in which classrooms are ventilated by large open windows in accordance with national building regulations and norms and standards for school design. The aim of the study was to establish a heuristic framework for early design decisions regarding how far from the road a classroom building should be set, and the effective height and position of a solid noise barrier to ensure a suitable ambient noise level inside a classroom with open windows. Efficacy was measured with reference to an indoor ambient sound level of 40 dBA. The findings show that with the insertion of barriers, the required ambient level was achieved for a classroom at least 68 m from the road, if the barrier is at least 3.5 m high. However, it was found that a significant insertion loss (>6 dB) and an improved signal to noise ratio could be achieved for classrooms as close as 17 m from the road with a barrier of at least 2 m high. Though not broadly generalizable, the findings provide a heuristic guide applicable for designing new schools or selecting attenuation interventions in existing city schools that are similar to those used in the study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
南非自然通风教室的交通噪音衰减解决方案
交通噪音通过自然通风教室的开窗传播会降低语音清晰度,并对学习成绩产生负面影响。给出了数值研究的结果。使用软件评估受交通噪音影响的自然通风教室的有效降噪解决方案。考虑南非豪登省城市学校的典型情况,根据国家建筑法规和学校设计规范和标准,教室采用大开窗通风。这项研究的目的是为早期设计决策建立一个启发式框架,比如教学楼应该离道路多远,以及固体隔音屏障的有效高度和位置,以确保开窗教室内的环境噪音水平合适。以40 dBA的室内环境声级为基准来测量效果。研究结果表明,如果屏障的高度至少为3.5米,那么在距离道路至少68米的教室中,设置屏障可以达到所需的环境水平。然而,研究发现,在距离道路17米且至少有2米高的屏障的教室中,可以实现显著的插入损耗(bbb6db)和改善的信噪比。虽然不能广泛推广,但研究结果为设计新学校或在现有城市学校中选择与研究中使用的类似的衰减干预措施提供了启发式指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BUILDING ACOUSTICS
BUILDING ACOUSTICS ACOUSTICS-
CiteScore
4.10
自引率
11.80%
发文量
22
期刊最新文献
Enhancing response estimation and system identification in structural health monitoring through data-driven approaches Effect of loudspeaker position and model on cognitive load, quality, clarity, and sentence recognition performance Determination of the sound absorption coefficient of ETFE cushions in-situ using the genetic material optimizer in Odeon® Methodological approaches and main factors considered in school soundscape studies: A scoping review The relationship between the in situ flanking sound reduction index and the laboratory measured flanking normalized level difference
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1