Amperometric biosensor for detection of triglyceride tributyrinbased on zero point charge of activated carbon

IF 1.1 4区 生物学 Q3 BIOLOGY Turkish Journal of Biology Pub Date : 2017-04-01 DOI:10.3906/BIY-1607-24
Mohsen Rezvani, G. Najafpour, M. Mohammadi, H. Zare
{"title":"Amperometric biosensor for detection of triglyceride tributyrinbased on zero point charge of activated carbon","authors":"Mohsen Rezvani, G. Najafpour, M. Mohammadi, H. Zare","doi":"10.3906/BIY-1607-24","DOIUrl":null,"url":null,"abstract":"A simple and robust single enzyme biosensor was fabricated for triglyceride (TG) detection. Graphite rods were modified with activated carbon (AC) and used as support for lipase immobilization. Chitosan (CHIT) was eventually used to create film on the bioelectrode and retain the immobilized enzyme. To extend the linear range of TG detection, AC was functionalized with carboxyl and then amine groups (AAC) to enhance the isoelectric point of AC. The constructed graphite/AAC/lipase /CHIT bioelectrode was characterized using cyclic voltammetry and field emission scanning electron microscopy (FE-SEM). The accuracy of the developed biosensor was assessed through determination of different concentrations of tributyrin (TB) in buffer solution. Linear responses were found for TB concentration in the range of 50 to 350 mg dL-1 with a detection limit of 9.9 mg dL-1. The biosensor showed good sensitivity of 0.16 μA mg-1 dL. The detected level of TG in several human serum specimens using the constructed biosensor was in good agreement with the results of an automatic biochemical analyzer. The fabricated biosensor was not affected by a number of human serum materials and showed a strong anti-interference ability. The relative standard deviation in reproducibility and repeatability tests was 3.46% and 2.94%, respectively.","PeriodicalId":23358,"journal":{"name":"Turkish Journal of Biology","volume":"41 1","pages":"268-277"},"PeriodicalIF":1.1000,"publicationDate":"2017-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3906/BIY-1607-24","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Biology","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3906/BIY-1607-24","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 7

Abstract

A simple and robust single enzyme biosensor was fabricated for triglyceride (TG) detection. Graphite rods were modified with activated carbon (AC) and used as support for lipase immobilization. Chitosan (CHIT) was eventually used to create film on the bioelectrode and retain the immobilized enzyme. To extend the linear range of TG detection, AC was functionalized with carboxyl and then amine groups (AAC) to enhance the isoelectric point of AC. The constructed graphite/AAC/lipase /CHIT bioelectrode was characterized using cyclic voltammetry and field emission scanning electron microscopy (FE-SEM). The accuracy of the developed biosensor was assessed through determination of different concentrations of tributyrin (TB) in buffer solution. Linear responses were found for TB concentration in the range of 50 to 350 mg dL-1 with a detection limit of 9.9 mg dL-1. The biosensor showed good sensitivity of 0.16 μA mg-1 dL. The detected level of TG in several human serum specimens using the constructed biosensor was in good agreement with the results of an automatic biochemical analyzer. The fabricated biosensor was not affected by a number of human serum materials and showed a strong anti-interference ability. The relative standard deviation in reproducibility and repeatability tests was 3.46% and 2.94%, respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于活性炭零点电荷的三丁酸甘油三酯检测的安培生物传感器
制备了一种检测甘油三酯(TG)的单酶传感器。用活性炭对石墨棒进行改性,并将其作为固定化脂肪酶的载体。壳聚糖(CHIT)最终用于在生物电极上形成膜并保留固定化酶。为了扩大热重检测的线性范围,先用羧基再用胺基(AAC)对AC进行功能化,以提高AC的等电点。利用循环伏安法和场发射扫描电镜(FE-SEM)对构建的石墨/AAC/脂肪酶/CHIT生物电极进行了表征。通过测定缓冲液中不同浓度的三丁酸甘油酯(TB)来评价所研制的生物传感器的准确性。在50 ~ 350 mg dL-1范围内呈线性关系,检出限为9.9 mg dL-1。该传感器灵敏度为0.16 μA mg-1 dL。用所构建的生物传感器对几种人血清样品的TG检测结果与全自动生化分析仪的结果吻合较好。制备的生物传感器不受多种人血清材料的影响,具有较强的抗干扰能力。重现性和重复性试验的相对标准偏差分别为3.46%和2.94%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.60
自引率
0.00%
发文量
20
审稿时长
6-12 weeks
期刊介绍: The Turkish Journal of Biology is published electronically 6 times a year by the Scientific and Technological Research Council of Turkey (TÜBİTAK) and accepts English-language manuscripts concerning all kinds of biological processes including biochemistry and biosynthesis, physiology and metabolism, molecular genetics, molecular biology, genomics, proteomics, molecular farming, biotechnology/genetic transformation, nanobiotechnology, bioinformatics and systems biology, cell and developmental biology, stem cell biology, and reproductive biology. Contribution is open to researchers of all nationalities.
期刊最新文献
Gooseberry anthocyanins alleviate insulin resistance by regulating ceramide metabolism in high fat diet mice Ribosomal protein L8 regulates the expression and splicing pattern of genes associated with cancer-related pathways Mitochondrial transplantation and transfer: The promising method for diseases Androgen receptor contributes to repairing DNA damage induced by inflammation and oxidative stress in prostate cancer Soloxolone methyl induces apoptosis and oxidative/ER stress in breast cancer cells and target cancer stem cell population
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1