Dosimetry Verification of Anisotropic Analytical Algorithm (AAA) In Eclipse Treatment Planning System (TPS) Based on Multileaf Collimator Variations

Fadillah Ahmad, Afdhal Muttaqin, D. Fitriyani, Ridwan Ridwan
{"title":"Dosimetry Verification of Anisotropic Analytical Algorithm (AAA) In Eclipse Treatment Planning System (TPS) Based on Multileaf Collimator Variations","authors":"Fadillah Ahmad, Afdhal Muttaqin, D. Fitriyani, Ridwan Ridwan","doi":"10.25077/jif.15.1.48-55.2023","DOIUrl":null,"url":null,"abstract":"Dosimetry verification of anisotropic analytical (AAA) algorithms based on variations of the multileaf collimator has been investigated using the Eclipse Treatment Planning System. This study used a 0.6cc ionization chamber farmer detector and Linac Clinical CX variant equipped with TPS Eclipse with AAA. This study used 6 MV energy and 2 Gy dose. The multileaf collimator was varied into six groups with the size (A, B, C, D, E, F) of the irradiation field used 20 cm x 20 cm. The measurement results were a dose deviation value or a dose ratio presentation in each irradiation area. The dose deviation of the multileaf collimator variation was A 0.86% for each group. Group B had 6.8%, Group C had -0.43%, Group D had 0.73%, Group E had 1.11%, and Group F had 0.84%. The mean dose deviation value for all multileaf collimator forms was 1.67%, where this value is within the tolerance value recommended by ICRU, namely 3-5%. The p-value in the Analysis of variance (ANOVA) for the entire group was 0.00. This data shows that there is no effect of variation in the multileaf collimator on the dose given.","PeriodicalId":52720,"journal":{"name":"JIF Jurnal Ilmu Fisika","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JIF Jurnal Ilmu Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/jif.15.1.48-55.2023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Dosimetry verification of anisotropic analytical (AAA) algorithms based on variations of the multileaf collimator has been investigated using the Eclipse Treatment Planning System. This study used a 0.6cc ionization chamber farmer detector and Linac Clinical CX variant equipped with TPS Eclipse with AAA. This study used 6 MV energy and 2 Gy dose. The multileaf collimator was varied into six groups with the size (A, B, C, D, E, F) of the irradiation field used 20 cm x 20 cm. The measurement results were a dose deviation value or a dose ratio presentation in each irradiation area. The dose deviation of the multileaf collimator variation was A 0.86% for each group. Group B had 6.8%, Group C had -0.43%, Group D had 0.73%, Group E had 1.11%, and Group F had 0.84%. The mean dose deviation value for all multileaf collimator forms was 1.67%, where this value is within the tolerance value recommended by ICRU, namely 3-5%. The p-value in the Analysis of variance (ANOVA) for the entire group was 0.00. This data shows that there is no effect of variation in the multileaf collimator on the dose given.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于多叶准直变化的食相治疗计划系统(TPS)中各向异性分析算法(AAA)的剂量学验证
使用Eclipse治疗计划系统研究了基于多叶准直器变化的各向异性分析(AAA)算法的剂量测定验证。本研究使用了0.6cc电离室农民探测器和配备了TPS Eclipse和AAA的Linac Clinical CX变体。本研究使用6MV能量和2Gy剂量。将多叶准直器分为六组,照射场大小(A、B、C、D、E、F)为20 cm x 20 cm。测量结果为每个照射区域的剂量偏差值或剂量比。各组多叶准直器变化的剂量偏差为A 0.86%。B组为6.8%,C组为-0.43%,D组为0.73%,E组为1.11%,F组为0.84%。所有多叶准直器形式的平均剂量偏差值为1.67%,在ICRU推荐的容许值范围内,即3-5%。整个组的方差分析(ANOVA)中的p值为0.00。该数据表明,多叶准直器的变化对所给剂量没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
7
审稿时长
6 weeks
期刊最新文献
Development of River Flow and Water Quality Using IOT-based Smart Buoys Environment Monitoring System Particle Size Improvement and Layer Absorption of Metil Halida MAPbI3 Perovskite Doping Phenethylammonium Iodide (PEAI) Efficiency at Maximum Power of Endoreversible Quantum Otto Engine with Partial Thermalization in 3D Harmonic Potential Wind Gust Parameterization Assessment under Convective and Non-convective Events: A Case Study at the Kertajati International Airport An Analysis of the Schrodinger Equation Model for the Distribution Rate of Stock Returns
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1