A 410-nW efficient QRS processor for mobile ECG monitoring in 0.18-μm CMOS

IF 3.8 2区 医学 Q2 ENGINEERING, BIOMEDICAL IEEE Transactions on Biomedical Circuits and Systems Pub Date : 2016-10-01 DOI:10.1109/BioCAS.2016.7833713
Peng Li, Hanjun Jiang, Wendi Yang, Ming Liu, Xu Zhang, Xiaohui Hu, B. Pang, Zhaolin Yao, Hongda Chen
{"title":"A 410-nW efficient QRS processor for mobile ECG monitoring in 0.18-μm CMOS","authors":"Peng Li, Hanjun Jiang, Wendi Yang, Ming Liu, Xu Zhang, Xiaohui Hu, B. Pang, Zhaolin Yao, Hongda Chen","doi":"10.1109/BioCAS.2016.7833713","DOIUrl":null,"url":null,"abstract":"This paper proposes a low power and efficient QRS processor for real-time and continuous mobile ECG monitoring. The QRS detection algorithm is based on the harr wavelet transform. In order to reduce power consumption, an optimized FIR filter structure is proposed. To improve accuracy, R position modification (RPM) has been designed. Fabricated with the 0.18-μm N-well CMOS 1P6M technology, power consumption of this chip is only 410 nW in 1 V voltage supply, which is much lower than that of previous work. Validated by all 48 databases in the MIT-BIH arrhythmia database, sensitivity (Se) and positive prediction (Pr) are 99.60% and 99.77% respectively.","PeriodicalId":13151,"journal":{"name":"IEEE Transactions on Biomedical Circuits and Systems","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/BioCAS.2016.7833713","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Biomedical Circuits and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1109/BioCAS.2016.7833713","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 6

Abstract

This paper proposes a low power and efficient QRS processor for real-time and continuous mobile ECG monitoring. The QRS detection algorithm is based on the harr wavelet transform. In order to reduce power consumption, an optimized FIR filter structure is proposed. To improve accuracy, R position modification (RPM) has been designed. Fabricated with the 0.18-μm N-well CMOS 1P6M technology, power consumption of this chip is only 410 nW in 1 V voltage supply, which is much lower than that of previous work. Validated by all 48 databases in the MIT-BIH arrhythmia database, sensitivity (Se) and positive prediction (Pr) are 99.60% and 99.77% respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于0.18 μm CMOS的移动心电监测的410-nW高效QRS处理器
提出了一种低功耗、高效的QRS处理器,用于实时、连续移动心电监测。QRS检测算法是基于harr小波变换的。为了降低功耗,提出了一种优化的FIR滤波器结构。为了提高精度,设计了R位置修正(RPM)。该芯片采用0.18 μm n阱CMOS 1P6M工艺制作,在1v电压下功耗仅为410 nW,大大低于之前的工作。通过MIT-BIH心律失常数据库中48个数据库的验证,灵敏度(Se)和阳性预测(Pr)分别为99.60%和99.77%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IEEE Transactions on Biomedical Circuits and Systems
IEEE Transactions on Biomedical Circuits and Systems 工程技术-工程:电子与电气
CiteScore
10.00
自引率
13.70%
发文量
174
审稿时长
3 months
期刊介绍: The IEEE Transactions on Biomedical Circuits and Systems addresses areas at the crossroads of Circuits and Systems and Life Sciences. The main emphasis is on microelectronic issues in a wide range of applications found in life sciences, physical sciences and engineering. The primary goal of the journal is to bridge the unique scientific and technical activities of the Circuits and Systems Society to a wide variety of related areas such as: • Bioelectronics • Implantable and wearable electronics like cochlear and retinal prosthesis, motor control, etc. • Biotechnology sensor circuits, integrated systems, and networks • Micropower imaging technology • BioMEMS • Lab-on-chip Bio-nanotechnology • Organic Semiconductors • Biomedical Engineering • Genomics and Proteomics • Neuromorphic Engineering • Smart sensors • Low power micro- and nanoelectronics • Mixed-mode system-on-chip • Wireless technology • Gene circuits and molecular circuits • System biology • Brain science and engineering: such as neuro-informatics, neural prosthesis, cognitive engineering, brain computer interface • Healthcare: information technology for biomedical, epidemiology, and other related life science applications. General, theoretical, and application-oriented papers in the abovementioned technical areas with a Circuits and Systems perspective are encouraged to publish in TBioCAS. Of special interest are biomedical-oriented papers with a Circuits and Systems angle.
期刊最新文献
A 1024-Channel Simultaneous Electrophysiological and Electrochemical Neural Recording System with In-Pixel Digitization and Crosstalk Compensation A 13.56-MHz 93.5%-Efficiency Optimal On/Off Timing Tracking Active Rectifier with Digital Feedback-Based Adaptive Delay Control An Ultra-Low Power Wearable BMI System with Continual Learning Capabilities Closed-Loop Implantable Neurostimulators for Individualized Treatment of Intractable Epilepsy: A Review of Recent Developments, Ongoing Challenges, and Future Opportunities Real-Time sEMG Processing with Spiking Neural Networks on a Low-Power 5K-LUT FPGA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1