{"title":"Optimalization of multiresidue method for the determination of pesticide residues in fruits","authors":"","doi":"10.14199/ppp-2021-025","DOIUrl":null,"url":null,"abstract":"The main aim of this study was to optimize the QuEChERS methodology for the comprehensive determination of pesticide residues using a simple and inexpensive gas chromatography equipped with selective detectors working simultaneously (GC-ECD/NPD). The method was validated in accordance with the SANTE/11945/2015 guidelines. Representative fruit matrices were chosen from the commodities group with high water content (apples), and with high acidity and high water content (strawberry) for a 160 compounds in the range of 0.005−0.02 mg/kg. The accuracy of the method was as required (recovery: 70–120%, precision: below 20%) for 135 active substances in apples samples and 137 in strawberries samples. The main advantages of the methodology include: good detector response linearity (R2 above 0.995), low limits of detection (0.005 mg/kg for more than 20 compounds, 0.01 mg/kg for about 120 compounds), possibility of simultaneous determination of a wide range of compounds (including some “difficult” ones) without use of a single residue methods. The simultaneous use of two selective detectors allows to obtain more data during a single dose of the sample and confirmation of the result for most compounds, which allows to prevent false positives ones.","PeriodicalId":20625,"journal":{"name":"Progress in Plant Protection","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Plant Protection","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14199/ppp-2021-025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Agricultural and Biological Sciences","Score":null,"Total":0}
引用次数: 2
Abstract
The main aim of this study was to optimize the QuEChERS methodology for the comprehensive determination of pesticide residues using a simple and inexpensive gas chromatography equipped with selective detectors working simultaneously (GC-ECD/NPD). The method was validated in accordance with the SANTE/11945/2015 guidelines. Representative fruit matrices were chosen from the commodities group with high water content (apples), and with high acidity and high water content (strawberry) for a 160 compounds in the range of 0.005−0.02 mg/kg. The accuracy of the method was as required (recovery: 70–120%, precision: below 20%) for 135 active substances in apples samples and 137 in strawberries samples. The main advantages of the methodology include: good detector response linearity (R2 above 0.995), low limits of detection (0.005 mg/kg for more than 20 compounds, 0.01 mg/kg for about 120 compounds), possibility of simultaneous determination of a wide range of compounds (including some “difficult” ones) without use of a single residue methods. The simultaneous use of two selective detectors allows to obtain more data during a single dose of the sample and confirmation of the result for most compounds, which allows to prevent false positives ones.