Trace nickel analysis in water samples via paper-based devices coupled with co-precipitation

IF 0.8 4区 化学 Q4 CHEMISTRY, MULTIDISCIPLINARY South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie Pub Date : 2023-01-01 DOI:10.17159/0379-4350/2023/v77a01
Abdellah Muhammed, A. Hussen, T. Kaneta
{"title":"Trace nickel analysis in water samples via paper-based devices coupled with co-precipitation","authors":"Abdellah Muhammed, A. Hussen, T. Kaneta","doi":"10.17159/0379-4350/2023/v77a01","DOIUrl":null,"url":null,"abstract":"A simple, fast, low-cost and sensitive microfluidic paper-based analytical device (u-PADs) integrated with the co-precipitation enrichment procedure was developed to analyse Ni(II) in tap and mineral water samples. The impacting factors, including pH, centrifugation (5 min at 4000 rpm), and amounts of reagents were optimized. The limit of detection of 0.009 mg L-1 and linear range of 0.03-2.00 mg L-1 were achieved with good intra- and inter-day precision (4.7 and 5.6% RSD, respectively). The recovery tests were conducted by spiking tap and mineral water samples and analyzed using the u-PADs after co-precipitation enrichment. The results obtained by the proposed method were validated by inductively coupled plasma-optical emission spectrometry (ICP-OES). The recoveries of the present method and ICP-OES were ranged from 92.4-106.8% and 92.9-97.2%, respectively. The two sets of (u-PADs and ICP-OES) results were in good agreement, as a paired t-test indicated no significant differences. The proposed method could be utilized for analyzing trace levels of Ni(II) in water samples in developing countries where the availability of conventional analytical instruments are significant problems.","PeriodicalId":49495,"journal":{"name":"South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.17159/0379-4350/2023/v77a01","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

A simple, fast, low-cost and sensitive microfluidic paper-based analytical device (u-PADs) integrated with the co-precipitation enrichment procedure was developed to analyse Ni(II) in tap and mineral water samples. The impacting factors, including pH, centrifugation (5 min at 4000 rpm), and amounts of reagents were optimized. The limit of detection of 0.009 mg L-1 and linear range of 0.03-2.00 mg L-1 were achieved with good intra- and inter-day precision (4.7 and 5.6% RSD, respectively). The recovery tests were conducted by spiking tap and mineral water samples and analyzed using the u-PADs after co-precipitation enrichment. The results obtained by the proposed method were validated by inductively coupled plasma-optical emission spectrometry (ICP-OES). The recoveries of the present method and ICP-OES were ranged from 92.4-106.8% and 92.9-97.2%, respectively. The two sets of (u-PADs and ICP-OES) results were in good agreement, as a paired t-test indicated no significant differences. The proposed method could be utilized for analyzing trace levels of Ni(II) in water samples in developing countries where the availability of conventional analytical instruments are significant problems.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用纸基共沉淀法分析水样中痕量镍
开发了一种简单、快速、低成本、灵敏的微流控纸基分析装置(u-PADs),该装置集成了共沉淀富集程序,用于分析自来水和矿泉水样品中的Ni(II)。对pH、4000rpm离心5min、试剂用量等影响因素进行了优化。检测限为0.009 mg L-1,线性范围为0.03 ~ 2.00 mg L-1,日内、日间精密度分别为4.7和5.6%。对自来水和矿泉水样品进行了回收试验,并对共沉淀富集后的u-PADs进行了分析。采用电感耦合等离子体发射光谱法(ICP-OES)对所得结果进行了验证。本方法加样回收率为92.4 ~ 106.8%,ICP-OES加样回收率为92.9 ~ 97.2%。两组(u-PADs和ICP-OES)结果一致,配对t检验显示无显著差异。所提出的方法可用于分析发展中国家水样中痕量Ni(II)水平,在这些国家,传统分析仪器的可用性是一个重大问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
6
审稿时长
>12 weeks
期刊介绍: Original work in all branches of chemistry is published in the South African Journal of Chemistry. Contributions in English may take the form of papers, short communications, or critical reviews.
期刊最新文献
Trace nickel analysis in water samples via paper-based devices coupled with co-precipitation Quinoline-benzofuran and quinoline-benzothiophene derivatives as antiplasmodium agents A simple method for colourimetric determination of silver using a home-made double beam photometer Re-screening and preliminary in vitro evaluation of resorcinol based Hsp90 inhibitors for potential protocidal activity Effects of calcination temperature of eggshell-derived CaO as a catalyst for biodiesel production from waste cooking oil
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1