A simple method for colourimetric determination of silver using a home-made double beam photometer

IF 0.8 4区 化学 Q4 CHEMISTRY, MULTIDISCIPLINARY South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie Pub Date : 2023-01-01 DOI:10.17159/0379-4350/2023/v77a03
M. Saadati
{"title":"A simple method for colourimetric determination of silver using a home-made double beam photometer","authors":"M. Saadati","doi":"10.17159/0379-4350/2023/v77a03","DOIUrl":null,"url":null,"abstract":"The present study proposes a simple and inexpensive photometric method for the selective determination of Ag(I). This method employed a home-made double beam photometer for the determination of silver ions based on an optode sensor prepared by immobilization of 5-(P-Dimethylaminobenzylidene)-rhodanine (PDR) on triacetyl cellulose (TAC) membrane. Two green LEDs as sources of light and light-dependent resistors (LDRs) as detectors were used in the proposed device. The LEDs are turned on by a programmable microcontroller that receives signals from light passed through the sensor, and the absorbance is calculated and displayed on a Liquid-crystal display (LCD) screen. With the optimum conditions, the calibration plot was linear in the concentration range of 0.5-6 μg mL-1. For five replicate determinations of 2 μg mL-1 Ag(I) and the related detection limits, the relative standard deviations were 2.29% and 0.25 μg mL-1, respectively. The method was applied successfully for determining silver in a silver sulphadiazine cream, a radiology effluent, and radiology film samples and the results obtained were in good agreement with those of the standard flame atomic absorption spectroscopy (FAAS) method.","PeriodicalId":49495,"journal":{"name":"South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie","volume":"1 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"South African Journal of Chemistry-Suid-Afrikaanse Tydskrif Vir Chemie","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.17159/0379-4350/2023/v77a03","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The present study proposes a simple and inexpensive photometric method for the selective determination of Ag(I). This method employed a home-made double beam photometer for the determination of silver ions based on an optode sensor prepared by immobilization of 5-(P-Dimethylaminobenzylidene)-rhodanine (PDR) on triacetyl cellulose (TAC) membrane. Two green LEDs as sources of light and light-dependent resistors (LDRs) as detectors were used in the proposed device. The LEDs are turned on by a programmable microcontroller that receives signals from light passed through the sensor, and the absorbance is calculated and displayed on a Liquid-crystal display (LCD) screen. With the optimum conditions, the calibration plot was linear in the concentration range of 0.5-6 μg mL-1. For five replicate determinations of 2 μg mL-1 Ag(I) and the related detection limits, the relative standard deviations were 2.29% and 0.25 μg mL-1, respectively. The method was applied successfully for determining silver in a silver sulphadiazine cream, a radiology effluent, and radiology film samples and the results obtained were in good agreement with those of the standard flame atomic absorption spectroscopy (FAAS) method.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用自制双光束光度计测定银的简单比色法
本研究提出了一种简单、廉价的选择性测定银(I)的光度法。本方法采用自制的双光束光度计,将5-(p -二甲氨基对苯二胺)-罗丹宁(PDR)固定在三乙酰纤维素(TAC)膜上制成光电传感器,用于银离子的测定。两个绿色led作为光源,光相关电阻(ldr)作为检测器被用于所提出的器件。led由一个可编程微控制器打开,该控制器接收通过传感器的光的信号,并计算吸光度并显示在液晶显示屏上。在最佳条件下,在0.5 ~ 6 μ mL-1的浓度范围内,标定曲线呈线性关系。对于2 μg mL-1 Ag(I)的5次重复测定及其检出限,相对标准偏差分别为2.29%和0.25 μg mL-1。该方法成功地应用于磺胺嘧啶银乳膏、放射学出水和放射学膜样品中的银的测定,所得结果与标准火焰原子吸收光谱法(FAAS)的测定结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.10
自引率
0.00%
发文量
6
审稿时长
>12 weeks
期刊介绍: Original work in all branches of chemistry is published in the South African Journal of Chemistry. Contributions in English may take the form of papers, short communications, or critical reviews.
期刊最新文献
Trace nickel analysis in water samples via paper-based devices coupled with co-precipitation Quinoline-benzofuran and quinoline-benzothiophene derivatives as antiplasmodium agents A simple method for colourimetric determination of silver using a home-made double beam photometer Re-screening and preliminary in vitro evaluation of resorcinol based Hsp90 inhibitors for potential protocidal activity Effects of calcination temperature of eggshell-derived CaO as a catalyst for biodiesel production from waste cooking oil
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1