On-Line Determination of Cyclophosphamide in Blood Samples Utilizing Microextraction by Packed Sorbent and Liquid Chromatography Tandem Mass Spectrometry (MEPS-LC-MS/MS)

M. Kamel, R. Said, Aziza El-Beqqali, F. Bassyouni, M. Abdel-Rehim
{"title":"On-Line Determination of Cyclophosphamide in Blood Samples Utilizing Microextraction by Packed Sorbent and Liquid Chromatography Tandem Mass Spectrometry (MEPS-LC-MS/MS)","authors":"M. Kamel, R. Said, Aziza El-Beqqali, F. Bassyouni, M. Abdel-Rehim","doi":"10.2174/1874383800903010026","DOIUrl":null,"url":null,"abstract":"Microextraction by packed sorbent (MEPS) was used to handle whole mice blood samples. MEPS was used as an online rapid sample-preparation method, followed by liquid chromatography with tandem mass spectrometry (LC- MS/MS). Cyclophosphamide in mice blood was used as a model compound. The new method reduced the handling time and the cost and could handle small volumes of whole blood samples (20 μL). The lower limit of quantification (LLOQ) was 0.1μg/mL. The accuracy of the quality-control (QC) samples ranged from 107 to 110 %. The within-day variation was within the range 2.0-7.0% (C.V.%) while the between-day variation was between 4.0 and 6.0% (C.V.%). The calibra- tion curve in whole blood was constructed within the concentration range 0.1-100 μg/mL. The coefficients of determina- tion (R 2 ) were > 0.99 (n = 3). The present method is rapid, reliable and accurate and may be used for therapeutic drug monitoring of cyclophosphamide in whole blood. The method was applied for preclinical study of cyclophosphamide in mice.","PeriodicalId":88758,"journal":{"name":"The open spectroscopy journal","volume":"3 1","pages":"26-30"},"PeriodicalIF":0.0000,"publicationDate":"2009-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The open spectroscopy journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874383800903010026","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Microextraction by packed sorbent (MEPS) was used to handle whole mice blood samples. MEPS was used as an online rapid sample-preparation method, followed by liquid chromatography with tandem mass spectrometry (LC- MS/MS). Cyclophosphamide in mice blood was used as a model compound. The new method reduced the handling time and the cost and could handle small volumes of whole blood samples (20 μL). The lower limit of quantification (LLOQ) was 0.1μg/mL. The accuracy of the quality-control (QC) samples ranged from 107 to 110 %. The within-day variation was within the range 2.0-7.0% (C.V.%) while the between-day variation was between 4.0 and 6.0% (C.V.%). The calibra- tion curve in whole blood was constructed within the concentration range 0.1-100 μg/mL. The coefficients of determina- tion (R 2 ) were > 0.99 (n = 3). The present method is rapid, reliable and accurate and may be used for therapeutic drug monitoring of cyclophosphamide in whole blood. The method was applied for preclinical study of cyclophosphamide in mice.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
微萃取-液相色谱-串联质谱(MEPS-LC-MS/MS)在线测定血液样品中的环磷酰胺
采用填充吸附剂微萃取法(MEPS)处理小鼠全血样品。采用MEPS作为在线快速制样方法,然后采用液相色谱-串联质谱(LC- MS/MS)进行制样。以小鼠血液中的环磷酰胺作为模型化合物。该方法减少了处理时间和成本,可以处理小体积(20 μL)的全血样本。定量下限为0.1μg/mL。质量控制(QC)样品的准确度在107 ~ 110%之间。日内变异范围为2.0 ~ 7.0% (C.V.%),日间变异范围为4.0 ~ 6.0% (C.V.%)。在0.1 ~ 100 μg/mL浓度范围内建立全血标定曲线。测定系数(r2)为0.99 (n = 3),本法快速、可靠、准确,可用于全血环磷酰胺治疗药物监测。将该方法应用于环磷酰胺在小鼠体内的临床前研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimal Conditions for a Multimode Laser Diode with Delayed Optical Feedback in Terahertz Time-Domain Spectroscopy A Spectroscopy-Based Multi-Analytical Approach for Studies in Conservation: Decorations in the Alexander Palace (Tsarskoye Selo) Rotational Isomerism of the Side Chains of Hydroxypropyl Cellulose in Aqueous Solution Observed Using Attenuated Total Reflectance Infrared Spectroscopy Effect of Alkaline Salts on Pyrolyzed Solid Wastes in Used Edible Oils: An Attenuated Total Reflectance Analysis of Surface Compounds as a Function of the Temperature Narrow-Linewidth Pr:YLF Laser for High-Resolution Raman Trace Gas Spectroscopy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1