Applications of cryogenic method to water vapor sampling from ambient air for isotopes analysis

Q4 Engineering Ocean and Polar Research Pub Date : 2016-12-30 DOI:10.4217/OPR.2016.38.4.339
Songyi Kim, Yeongcheol Han, S. Hur, Jeonghoon Lee
{"title":"Applications of cryogenic method to water vapor sampling from ambient air for isotopes analysis","authors":"Songyi Kim, Yeongcheol Han, S. Hur, Jeonghoon Lee","doi":"10.4217/OPR.2016.38.4.339","DOIUrl":null,"url":null,"abstract":"Stable water vapor isotopes have been utilized as a tracer for studying atmospheric global circulations, climate change and paleoclimate with ice cores. Recently, since laser spectroscopy has been available, water vapor isotopes can be measured more precisely and continuously. Studies of water vapor isotopes have been conducted over the world, but it is the early stage in south Korea. For vapor isotopes study, a cryogenic sampling device for water vapor isotopes has been developed. The cryogenic sampling device consists of the dewar bottle, filled with extremely low temperature material and impinger connected with a vacuum pump. Impinger stays put in the dewar bottle to change the water vapor which passes through the inside of impinger into the solid phase as ice. The fact that water vapor has not sampled completely leads to isotopic fractionation in the impinger. To minimize the isotopic fractionation during sampling water vapor, we have tested the method using a serial connection with two sets of impinger device in the laboratory. We trapped 98.02% of water vapor in the first trap and the isotopic difference of the trapped water vapor between two impinger were about 20‰ and 6‰ for hydrogen and oxygen, respectively. Considering the amount of water vapor trapped in each impinger, the isotopic differences for hydrogen and oxygen were 0.33‰ and 0.06‰, respectively, which is significantly smaller than the precision of isotopic measurements. This work can conclude that there is no significant fractionation during water vapor trapping.","PeriodicalId":35665,"journal":{"name":"Ocean and Polar Research","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ocean and Polar Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4217/OPR.2016.38.4.339","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 2

Abstract

Stable water vapor isotopes have been utilized as a tracer for studying atmospheric global circulations, climate change and paleoclimate with ice cores. Recently, since laser spectroscopy has been available, water vapor isotopes can be measured more precisely and continuously. Studies of water vapor isotopes have been conducted over the world, but it is the early stage in south Korea. For vapor isotopes study, a cryogenic sampling device for water vapor isotopes has been developed. The cryogenic sampling device consists of the dewar bottle, filled with extremely low temperature material and impinger connected with a vacuum pump. Impinger stays put in the dewar bottle to change the water vapor which passes through the inside of impinger into the solid phase as ice. The fact that water vapor has not sampled completely leads to isotopic fractionation in the impinger. To minimize the isotopic fractionation during sampling water vapor, we have tested the method using a serial connection with two sets of impinger device in the laboratory. We trapped 98.02% of water vapor in the first trap and the isotopic difference of the trapped water vapor between two impinger were about 20‰ and 6‰ for hydrogen and oxygen, respectively. Considering the amount of water vapor trapped in each impinger, the isotopic differences for hydrogen and oxygen were 0.33‰ and 0.06‰, respectively, which is significantly smaller than the precision of isotopic measurements. This work can conclude that there is no significant fractionation during water vapor trapping.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低温法在环境空气中水蒸气取样用于同位素分析中的应用
稳定的水蒸气同位素作为示踪剂已被用于研究大气全球环流、气候变化和古气候的冰芯。最近,由于有了激光光谱学,可以更精确和连续地测量水蒸气的同位素。世界各地都在进行水蒸气同位素的研究,但在韩国还处于初级阶段。为了研究水蒸气同位素,研制了一种水蒸气同位素低温采样装置。低温取样装置由装满极低温材料的杜瓦瓶和连接真空泵的冲击器组成。撞击器被放置在杜瓦瓶中,使穿过撞击器内部的水蒸气变成固态的冰。水蒸气没有完全取样的事实导致了撞击器中的同位素分馏。为了最大限度地减少水蒸气取样过程中的同位素分馏,我们在实验室中用两套冲击器进行了串联测试。第一个捕集器捕获了98.02%的水蒸气,两个捕集器捕获的水蒸气中氢和氧的同位素差异分别约为20‰和6‰。考虑到每个撞击器捕获的水蒸气量,氢和氧的同位素差异分别为0.33‰和0.06‰,明显小于同位素测量的精度。这项工作可以得出结论,在水蒸气捕获过程中没有显著的分馏。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ocean and Polar Research
Ocean and Polar Research Engineering-Ocean Engineering
CiteScore
0.80
自引率
0.00%
发文量
0
期刊最新文献
Weekly Variation of Prokaryotic Growth and Diversity in the Inner Bay of Yeong-do, Busan Estimation of Extreme Wind Speeds in the Western North Pacific Using Reanalysis Data Synthesized with Empirical Typhoon Vortex Model Correlation Analysis Between the Variation of Net Surface Heat Flux Around the East Asian Seas and the Air Temperature and Precipitation Over the Korean Peninsula Comparison of Morphological Analysis and DNA Metabarcoding of Crustacean Mesozooplankton in the Yellow Sea Study on Load Reduction of a Tidal Steam Turbine Using a Flapped Blade
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1