Green Chemistry: A Simple Manual Apparatus for Potentiometric and Conductometric Micro-Titration of Small Samples for the Educational Laboratory

IF 0.4 Q4 CHEMISTRY, MULTIDISCIPLINARY Jordan Journal of Chemistry Pub Date : 1900-01-01 DOI:10.47014/16.1.2
{"title":"Green Chemistry: A Simple Manual Apparatus for Potentiometric and Conductometric Micro-Titration of Small Samples for the Educational Laboratory","authors":"","doi":"10.47014/16.1.2","DOIUrl":null,"url":null,"abstract":"A simple manual micro-titration method is proposed for the potentiometric and conductometric titration of 200 to 800 µL of liquid samples. The sample to be titrated is dispensed into the titration chamber; the bottom section of a plastic test tube that is glued to the center of a small stirring magnet. After inserting the sensing probe and the tip of the titrant delivery tip into the titration chamber, the chamber-stirring magnet assembly is spun at low speed using a conventional magnetic stirrer. Titrant is delivered (with 0.2 µL resolution) from the submerged tip of a 100-µL capacity micro-pipette by rotating the plunger with the locking ring unlocked. The apparatus has been used for potentiometric titration and conductometric titration of acids and bases usually encountered in educational laboratories. Compared with macro-scale titrations, the obtained accuracy was between +2.2% and -3.9% relative error and the precision ranged between 1.6% and 2.9% relative standard deviation. The proposed procedure cuts the reagent consumption to 1% or less compared with conventional macro-scale titrations.","PeriodicalId":14654,"journal":{"name":"Jordan Journal of Chemistry","volume":"1 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jordan Journal of Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47014/16.1.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 1

Abstract

A simple manual micro-titration method is proposed for the potentiometric and conductometric titration of 200 to 800 µL of liquid samples. The sample to be titrated is dispensed into the titration chamber; the bottom section of a plastic test tube that is glued to the center of a small stirring magnet. After inserting the sensing probe and the tip of the titrant delivery tip into the titration chamber, the chamber-stirring magnet assembly is spun at low speed using a conventional magnetic stirrer. Titrant is delivered (with 0.2 µL resolution) from the submerged tip of a 100-µL capacity micro-pipette by rotating the plunger with the locking ring unlocked. The apparatus has been used for potentiometric titration and conductometric titration of acids and bases usually encountered in educational laboratories. Compared with macro-scale titrations, the obtained accuracy was between +2.2% and -3.9% relative error and the precision ranged between 1.6% and 2.9% relative standard deviation. The proposed procedure cuts the reagent consumption to 1% or less compared with conventional macro-scale titrations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
绿色化学:用于教育实验室小样品电位和电导微滴定的简易手动仪器
提出了一种简单的手动微滴定法,用于200 ~ 800µL液体样品的电位滴定和电导滴定。将待滴定的样品分配到滴定室中;塑料试管的底部,粘在一个小的搅拌磁铁的中心。将感应探针和滴定剂输送端尖插入滴定室后,使用常规磁力搅拌器低速旋转室搅拌磁铁组件。通过旋转柱塞,锁定环解锁,滴定剂从100µL容量的微移液管的浸没尖端(0.2µL分辨率)交付。该仪器已用于教育实验室中经常遇到的酸和碱的电位滴定和电导滴定。与宏观滴定法相比,准确度相对误差在+2.2% ~ -3.9%之间,精密度相对标准差在1.6% ~ 2.9%之间。与传统的大规模滴定相比,所提出的程序将试剂消耗减少到1%或更少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Jordan Journal of Chemistry
Jordan Journal of Chemistry CHEMISTRY, MULTIDISCIPLINARY-
CiteScore
0.50
自引率
0.00%
发文量
7
期刊最新文献
Synthesis and Antimicrobial Activity of Some Piperid-4-one Derivatives against Bacterial Strains Preparation, Characterization and Antimicrobial Activity of Pd(II), Zn(II) and Cu(II) Complexes of Benzimidazoles and Schiff Bases Including Ferrocene Group Ethnomedicinal Uses, Antidiabetic, Antioxidant and Anti-inflammatory Activity of Gmelina arborea Roxb. and Its Bioactive Compounds: A Review Determination and Classification of Jordanian Propolis Samples According to Their Elemental Profile Chromatographic and Automated Spectrophotometric Determination of Some Antipsychotic Drugs in Pharmaceutical Products
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1